Literature DB >> 29131179

Improved back-projection method for circular-scanning-based photoacoustic tomography with improved tangential resolution.

Jiaying Xiao, Xiaofei Luo, Kuan Peng, Bo Wang.   

Abstract

While photoacoustic computed tomography (PACT) is generally built with planar transducers of finite size, most current reconstruction algorithms assume the transducer to be an ideal point, which leads to a spinning blur in the consequently obtained PACT images due to the model mismatch. In this work, we put forward an improved back-projection method that factors in the geometry of the transducers to improve the tangential resolution for the reconstruction of 2D circular-scanning-based photoacoustic tomography. Extensive simulations and experiments were carried out to study the adaptability and stability of the proposed method. Results show that this method can effectively restore the tangential distortion of the PACT image for both simulated and experimental data. Results indicated that the improvement of the tangential resolution is more obvious for transducers with larger size. We also demonstrated the application of this method to transducers other than planar, and results show that the reconstructed image quality can be significantly affected by the shape and position of the transducers used. This study may help to guide the selection of transducer and design of scanning strategy in PACT.

Year:  2017        PMID: 29131179     DOI: 10.1364/AO.56.008983

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  4 in total

1.  Algebraic determination of back-projection operators for optoacoustic tomography.

Authors:  Amir Rosenthal
Journal:  Biomed Opt Express       Date:  2018-10-04       Impact factor: 3.732

2.  Multi-angle data acquisition to compensate transducer finite size in photoacoustic tomography.

Authors:  Soheil Hakakzadeh; Moein Mozaffarzadeh; Seyed Masood Mostafavi; Zahra Kavehvash; Praveenbalaji Rajendran; Martin Verweij; Nico de Jong; Manojit Pramanik
Journal:  Photoacoustics       Date:  2022-05-21

3.  Back-projection algorithm in generalized form for circular-scanning-based photoacoustic tomography with improved tangential resolution.

Authors:  Bo Wang; Tianning Su; Weiran Pang; Ningning Wei; Jiaying Xiao; Kuan Peng
Journal:  Quant Imaging Med Surg       Date:  2019-03

4.  Co-optimization method to improve lateral resolution in photoacoustic computed tomography.

Authors:  Yang Zhang; Shufan Yang; Zhiying Xia; Ruijie Hou; Bin Xu; Lianping Hou; John H Marsh; Jamie Jiangmin Hou; Seyed Mojtaba Rezaei Sani; Xuefeng Liu; Jichuan Xiong
Journal:  Biomed Opt Express       Date:  2022-08-09       Impact factor: 3.562

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.