Literature DB >> 29130519

Velocity reconstruction with nonconvex optimization for low-velocity-encoding phase-contrast MRI.

Michael Loecher1, Daniel B Ennis1,2.   

Abstract

PURPOSE: To introduce and demonstrate a nonconvex optimization method for reconstructing velocity data from low-velocity-encoding (Venc ) phase-contrast MRI data. THEORY AND METHODS: Solving for velocity values from phase-contrast MRI data was formulated as a nonconvex optimization problem. Weighting was added to account for intravoxel dephasing, and a Laplacian-based regularization was used to account for residual velocity aliasing. The reconstruction was tested with two low-Venc schemes: dual-Venc and a multidirectional high-moment encoding. The reconstruction method was tested in a digital simulation, in flow phantoms, and in healthy volunteers (N = 5).
RESULTS: The nonconvex-optimization reconstruction velocity error was lower than the conventional reconstruction in simulations (4.6 versus 3.0 cm/s for multidirectional high moment, 8.3 versus 3.8 cm/s for dual-Venc ) and in flow phantoms (23.9 versus 5.9 cm/s for multidirectional high moment, 15.2 versus 6.4 cm/s for dual-Venc ). Qualitative assessment of velocity fields in all experiments, including healthy volunteers, showed decreased apparent noise in the velocity fields and fewer phase wraps. No additional velocity bias in measured velocities was seen in volunteers with the proposed method.
CONCLUSIONS: The proposed nonconvex-optimization reconstruction method incorporates additional information to solve for velocities when using any type of low-Venc (high-moment) acquisition. The method reduces the amount of residual phase aliasing, and decreases velocity errors that result from intravoxel dephasing. These improvements allow for more robust acquisitions, and for Venc to be lowered 2 to 4 times relative to conventional acquisitions, thereby increasing the velocity-to-noise ratio. Magn Reson Med, 2017.
© 2017 International Society for Magnetic Resonance in Medicine. Magn Reson Med 80:42-52, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  intravoxel dephasing; low Venc; nonconvex optimization; phase contrast; reconstruction

Mesh:

Substances:

Year:  2017        PMID: 29130519     DOI: 10.1002/mrm.26997

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  3 in total

1.  Efficient triple-VENC phase-contrast MRI for improved velocity dynamic range.

Authors:  Liliana E Ma; Michael Markl; Kelvin Chow; Alireza Vali; Can Wu; Susanne Schnell
Journal:  Magn Reson Med       Date:  2019-08-18       Impact factor: 4.668

2.  4D Flow MR Imaging to Improve Microwave Ablation Prediction Models: A Feasibility Study in an In Vivo Porcine Liver.

Authors:  Jason Chiang; Michael Loecher; Kevin Moulin; M Franca Meloni; Steven S Raman; Justin P McWilliams; Daniel B Ennis; Edward W Lee
Journal:  J Vasc Interv Radiol       Date:  2020-03-13       Impact factor: 3.464

3.  Divergence-Free Constrained Phase Unwrapping and Denoising for 4D Flow MRI Using Weighted Least-Squares.

Authors:  Jiacheng Zhang; Sean M Rothenberger; Melissa C Brindise; Michael B Scott; Haben Berhane; Justin J Baraboo; Michael Markl; Vitaliy L Rayz; Pavlos P Vlachos
Journal:  IEEE Trans Med Imaging       Date:  2021-11-30       Impact factor: 10.048

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.