Orthodontic and periodontal splints are prepared with round or flat metallic wires. As these devices cannot be used in patients with allergy to metals or with aesthetic demands, fiber-reinforced composite (FRC) retainers have been introduced. Stiffness of FRC materials could reduce physiologic tooth movement. In order to lower rigidity of conventional FRC retainers, a modified construction technique that provided a partial (spot) composite coverage of the fiber has been tested and compared with metallic splints and full-bonded FRCs. Flat (Bond-a-Braid, Reliance Orthodontic Products) and round (Penta-one 0155, Masel Orthodontics) stainless steel splints, conventional FRC splints, and experimental spot-bonded FRC retainers (Everstick Ortho, StickTech) were investigated. The strength to bend the retainers at 0.1 mm deflection and at maximum load was measured with a modified Frasaco model. No significant differences were reported among load values of stainless steel wires and experimental spot-bonded FRC retainers at 0.1 mm deflection. Higher strength values were recoded for conventional full-bonded FRCs. At maximum load no significant differences were reported between metallic splints (flat and round) and experimental spot-bonded FRCs, and no significant differences were reported between spot- and full-bonded FRC splints. These results encourage further tests in order to evaluate clinical applications of experimental spot-bonded FRC retainers.Entities:
Mesh:
Year: 2017 PMID: 29130047 PMCID: PMC5654344 DOI: 10.1155/2017/8469090
Source DB: PubMed Journal: Biomed Res Int Impact factor: 3.411
Materials tested.
| Denomination | Flat metallic wire | Round metallic wire | Fiber reinforced composite | Fiber reinforced composite |
|---|---|---|---|---|
| Code | FW | RW | SF | FF |
| Manufacturer | Reliance | Masel | StickTech | StickTech |
| Name | Bond-a-Braid | Penta-one 0155 | FRC Ortho | FRC Ortho |
| Design | Ribbon arch | Coaxial | Unidirectional fiber bundle | Unidirectional fiber bundle |
| Material | Stainless steel | Stainless steel | E-glass fiber 15 | E-glass fiber 15 |
| Dimensions | 0.673 mm × 0.268 mm | Diameter: 0.394 mm | Diameter: 0.75 mm | Diameter: 0.75 mm |
| Unit amount | 8 wires | 5 wires | 1000 fibers | 1000 fibers |
| Bonding technique | Conventional spot | Conventional spot | Experimental spot | Conventional full |
Figure 1Flat metallic splint (a) round metallic splint (b) experimental spot-bonded FRC (c) and conventional full-bonded FRC (d).
Descriptive statistics (N) of load values of the 8 groups tested (each group consisted of 10 specimens).
| Group | Code | Material | Shape | Bonding | Deflection | Mean | SD | Min | Mdn | Max | Post hoc |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | FW | Stainless steel | Flat wire | Spot bonded | 0.1 mm | 8.33 | 1.68 | 6.19 | 8.90 | 10.76 | A |
| 2 | RW | Stainless steel | Round wire | Spot bonded | 0.1 mm | 4.24 | 1.16 | 3.23 | 3.84 | 6.66 | A |
| 3 | FS | FRC | Fiber bundle | Spot bonded | 0.1 mm | 16.67 | 2.08 | 13.53 | 16.18 | 19.33 | A |
| 4 | FF | FRC | Fiber bundle | Full bonded | 0.1 mm | 41.73 | 16.16 | 12.18 | 44.52 | 58.64 | B, C, D |
| 5 | FW | Stainless steel | Flat wire | Spot bonded | max load | 34.96 | 6.76 | 22.86 | 35.79 | 44.86 | B |
| 6 | RW | Stainless steel | Round wire | Spot bonded | max load | 35.62 | 10.26 | 21.22 | 38.19 | 50.74 | B |
| 7 | FS | FRC | Fiber bundle | Spot bonded | max load | 41.44 | 9.19 | 29.31 | 40.32 | 53.46 | B, D |
| 8 | FF | FRC | Fiber bundle | Full bonded | max load | 52.93 | 18.84 | 15.24 | 57.88 | 74.12 | C, D |
Mean with same letters is not significantly different.
Figure 2Box plot of strength values (N) of the various groups tested at 0.1 mm deflection.