Literature DB >> 26511774

Influence of abutment tooth position and adhesive point dimension on the rigidity of a dental trauma wire-composite splint.

Yuqing Zhu1, Hui Chen1, Lian Cen2,3, Jun Wang1.   

Abstract

BACKGROUND/AIM: The influence of abutment tooth position and adhesive point dimension on rigidity of wire-composite splints, used in dental trauma, was evaluated in vitro.
MATERIALS AND METHODS: A commercial artificial resin model was used. The central incisors served as injured teeth with increased mobility (degrees of loosening II tooth 21 and III tooth 11), whereas teeth 12/22 or teeth 13/23 served as non-injured teeth with physiological mobility. Horizontal and vertical tooth mobility before and after splinting was assessed, using a universal testing machine. Teeth were splinted with a wire-composite splint (0.8 mm). Four groups were assigned with respective abutment tooth position and adhesive point dimension: group 1 (13-11-21-23, 2 × 2 mm(2) ), group 2 (12-11-21-22, 2 × 2 mm(2) ), group 3 (12-11-21-22, 3 × 3 mm(2) ), group 4 (12-11-21-22, 4 × 4 mm(2) ).
RESULTS: For each group, tooth mobility after splinting was significantly higher than the physiological tooth mobility (P < 0.05). For teeth 11 and 12, no significant differences between Group 1 and 2 (P > 0.05) were found in tooth mobility after splinting. Significant differences were found in horizontal tooth mobility after splinting of tooth 11 between Group 2 and 3, Group 2 and 4 and Group 3 and 4, respectively (P < 0.05), whereas significant difference was found in vertical dimension for tooth 11 only between Group 2 and 4 (P < 0.05). Significant differences were found in horizontal mobility of tooth 21 between Group 2 and 3, and Group 2 and 4 (P < 0.05).
CONCLUSION: Splinting the injured teeth 11 and 21 and the bilateral uninjured abutment teeth (teeth 12/22 or teeth 13/23) with the stainless steel wire-composite splint (0.8 mm), can be considered flexible splinting. While mobility was still higher than in unaffected teeth, increase in size of the adhesive splinting point decreased horizontal but not vertical mobility in most cases.
© 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  abutment location; adhesive point dimension; dental trauma; rigidity; wire-composite splint

Mesh:

Substances:

Year:  2015        PMID: 26511774     DOI: 10.1111/edt.12241

Source DB:  PubMed          Journal:  Dent Traumatol        ISSN: 1600-4469            Impact factor:   3.333


  3 in total

1.  Bending Properties of Fiber-Reinforced Composites Retainers Bonded with Spot-Composite Coverage.

Authors:  Maria Francesca Sfondrini; Paola Gandini; Paola Tessera; Pekka K Vallittu; Lippo Lassila; Andrea Scribante
Journal:  Biomed Res Int       Date:  2017-10-10       Impact factor: 3.411

2.  Effect of Long-Term Brushing on Deflection, Maximum Load, and Wear of Stainless Steel Wires and Conventional and Spot Bonded Fiber-Reinforced Composites.

Authors:  Andrea Scribante; Pekka Vallittu; Lippo V J Lassila; Annalisa Viola; Paola Tessera; Paola Gandini; Maria Francesca Sfondrini
Journal:  Int J Mol Sci       Date:  2019-11-30       Impact factor: 5.923

3.  Spot-Bonding and Full-Bonding Techniques for Fiber Reinforced Composite (FRC) and Metallic Retainers.

Authors:  Andrea Scribante; Paola Gandini; Paola Tessera; Pekka K Vallittu; Lippo Lassila; Maria Francesca Sfondrini
Journal:  Int J Mol Sci       Date:  2017-10-04       Impact factor: 5.923

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.