Literature DB >> 2913003

Size of the femoral head and acetabular revision in total hip-replacement arthroplasty.

B F Morrey1, D Ilstrup.   

Abstract

Fifty-nine revisions that were done for aseptic acetabular loosening after 6,128 total hip arthroplasties for degenerative arthritis or traumatic arthritis were studied. These revisions were in forty-four (approximately 1 per cent) of 4,576 hips that had a twenty-two-millimeter femoral-head component, in two of 520 that had a twenty-eight-millimeter femoral-head component, and in thirteen (approximately 2.5 per cent) of 487 that had a thirty-two-millimeter femoral-head component. Therefore, the thirty-two-millimeter femoral component was associated with the highest rate of acetabular revision (p less than 0.001). The dimensions of the acetabular wall were thinner in the hips that had the thirty-two-millimeter component than in those that had the twenty-two-millimeter component (p less than 0.05). Multivariate analysis demonstrated a significantly increased risk of acetabular loosening in men and in patients who were less than sixty years old.

Entities:  

Mesh:

Year:  1989        PMID: 2913003

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  6 in total

1.  Retrieved total hip prostheses. Part I: the effects of cup thickness, head sizes and fusion defects on wear.

Authors:  H Oonishi; E Tsuji; Y Y Kim
Journal:  J Mater Sci Mater Med       Date:  1998-07       Impact factor: 3.896

Review 2.  Total hip arthroplasty.

Authors:  J S Siopack; H E Jergesen
Journal:  West J Med       Date:  1995-03

3.  Current attitudes to cementing techniques in British hip surgery.

Authors:  A Hashemi-Nejad; N C Birch; N J Goddard
Journal:  Ann R Coll Surg Engl       Date:  1994-11       Impact factor: 1.891

Review 4.  Patient characteristics affecting the prognosis of total hip and knee joint arthroplasty: a systematic review.

Authors:  Pasqualina L Santaguida; Gillian A Hawker; Pamela L Hudak; Richard Glazier; Nizar N Mahomed; Hans J Kreder; Peter C Coyte; James G Wright
Journal:  Can J Surg       Date:  2008-12       Impact factor: 2.089

5.  Clinical biomechanics of wear in total hip arthroplasty.

Authors:  John J Callaghan; Douglas R Pedersen; Richard C Johnston; Thomas D Brown
Journal:  Iowa Orthop J       Date:  2003

6.  A single-component and hemi-hip prosthesis followed up for 43 years: A case report.

Authors:  Yuan Liu; Hang-Jun Chen; Bin Zhang; Xu-Qiang Liu; Jun Xiao; Cheng-Kung Cheng; Min Dai
Journal:  Medicine (Baltimore)       Date:  2019-02       Impact factor: 1.889

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.