Literature DB >> 29128376

Radial head replacement with a bipolar system: an average 10-year follow-up.

Robert A Sershon1, Timothy J Luchetti2, Mark S Cohen1, Robert W Wysocki1.   

Abstract

BACKGROUND: We report the long-term results of a cohort of patients after radial head replacement with a bipolar design and a smooth cementless stem at a mean follow-up of 10.4 years.
METHODS: Of 17 possible patients from a previous minimum 2-year follow-up study, 16 were available for review. Patients were assessed using clinical and radiographic examination and with standardized outcome measures. Range of motion, stability, and radiographic evaluation of implant loosening and joint degeneration were assessed. Comparisons were performed using the Wilcoxon signed rank test for unequal groups.
RESULTS: The average follow-up was 10.5 years (range, 8.5-12 years). The median visual analog scale was 1 (range, 0-5), Minnesota Elbow Performance Index was 93 (range, 70-100), and the Disabilities of the Arm, Shoulder and Hand was 7.5 (range, 0-53). Range of motion was decreased on the operative side compared with the nonoperative side for flexion/extension (P = .005) and pronation/supination (P = .015). Grip strength was decreased on the affected side (P = .045). No patients had elbow instability. Significant arthritic changes developed in 2 patients at the ulnohumeral joint. The median cantilever quotient was 0.4 (range, 0.30-0.50). Osteolysis in zones 1 to 7 was found in all but 2 patients. The median stem radiolucency was 0.5 mm (range, 0.2-0.9 mm). No reoperations occurred since our previous report. Implant survival in this cohort was 97%.
CONCLUSION: Bipolar radial head prosthesis with a smooth cementless stem effectively restores elbow stability and function after comminuted radial head fractures with or without concomitant elbow instability. Our study demonstrates excellent long-term implant survival.
Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  bipolar; elbow reconstruction; outcomes; radial head; radial head arthroplasty; radial head fracture

Mesh:

Year:  2017        PMID: 29128376     DOI: 10.1016/j.jse.2017.09.015

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  10 in total

1.  Mid-term clinical outcome comparison of long-stemmed monopolar osseointegrated and short-stemmed bipolar radial head prostheses.

Authors:  Yves Gramlich; Eva Krausch; Thomas Stein; Kai Schmidt-Horlohé; Reinhard Hoffmann; Alexander Klug
Journal:  Arch Orthop Trauma Surg       Date:  2020-07-27       Impact factor: 3.067

Review 2.  Radial head arthroplasty: a historical perspective.

Authors:  Pierre Laumonerie; Meagan E Tibbo; Nicolas Reina; Thuy Trang Pham; Nicolas Bonnevialle; Pierre Mansat
Journal:  Int Orthop       Date:  2018-08-10       Impact factor: 3.075

3.  A registry study on radial head arthroplasties in the Netherlands: Indications, types and short-term survival.

Authors:  Arno A Macken; Ante Prkić; Koen Lm Koenraadt; Iris van Oost; Anneke Spekenbrink-Spooren; Bertram The; Denise Eygendaal
Journal:  Shoulder Elbow       Date:  2021-01-21

4.  Survivorship of anatomic press-fit short-stem radial head replacement with a pyrocarbon bearing.

Authors:  Aparna I Viswanath; Adam C Watts
Journal:  Shoulder Elbow       Date:  2021-06-17

5.  Fracture Pattern Influences Radial Head Replacement Size Determination Among Experienced Elbow Surgeons.

Authors:  Davide Cucchi; Francesco Luceri; Andrea Celli; Alessandra Menon; Raul Barco; Kilian Wegmann; Pietro Randelli; Denise Eygendaal; Paolo Arrigoni
Journal:  Indian J Orthop       Date:  2020-03-18       Impact factor: 1.251

6.  High Risk of Further Surgery After Radial Head Replacement for Unstable Fractures: Longer-term Outcomes at a Minimum Follow-up of 8 Years.

Authors:  Caroline D Cristofaro; Thomas H Carter; Neil R Wickramasinghe; Margaret M McQueen; Timothy O White; Andrew D Duckworth
Journal:  Clin Orthop Relat Res       Date:  2019-11       Impact factor: 4.176

Review 7.  Indications and outcomes of radial head excision: A systematic review.

Authors:  Alexandra H Hildebrand; Betty Zhang; Nolan S Horner; Graham King; Moin Khan; Bashar Alolabi
Journal:  Shoulder Elbow       Date:  2019-07-31

Review 8.  Why does radial head arthroplasty fail today? A systematic review of recent literature.

Authors:  Jetske Viveen; Izaak F Kodde; Andras Heijink; Koen L M Koenraadt; Michel P J van den Bekerom; Denise Eygendaal
Journal:  EFORT Open Rev       Date:  2020-01-28

9.  Short- to mid-term outcomes of radial head replacement for complex radial head fractures.

Authors:  Chung-Sin Baek; Beom-Soo Kim; Du-Han Kim; Chul-Hyun Cho
Journal:  Clin Shoulder Elb       Date:  2020-11-26

10.  Acute radial head replacement with bipolar prostheses: midterm results.

Authors:  Alessandro Nosenzo; Cristina Galavotti; Margherita Menozzi; Alice Garzia; Francesco Pogliacomi; Filippo Calderazzi
Journal:  Eur J Orthop Surg Traumatol       Date:  2020-08-31
  10 in total