Literature DB >> 29127197

Communicating malapposition of flow diverters assessed with optical coherence tomography correlates with delayed aneurysm occlusion.

Robert M King1, Olivia W Brooks1, Erin T Langan1, Jildaz Caroff1,2, Frédéric Clarençon3, Takamitsu Tamura1, John Michael Wainwright4, Matthew J Gounis1, Miklós Marosfői1, Ajit S Puri1.   

Abstract

BACKGROUND: Optical coherence tomography (OCT) is a high resolution intravascular imaging method that allows visualization of flow diverter struts and the vessel wall. In this study, malapposition of the flow diverter that continues into the neck of the aneurysm, named communicating malapposition (CM), was investigated as a potential factor for delayed aneurysm healing.
METHODS: 40 New Zealand White rabbits underwent elastase induced aneurysm creation, and were subsequently assigned to one of four treatment groups based on flow diverter type and administration of antiplatelet therapy. All animals underwent post device deployment balloon angioplasty and subsequent OCT to assess device/vessel apposition. The incidence of CM seen on OCT was assessed with a binary scoring system: 0-CM present; 1-CM absent. At 30 days, DSA was acquired to assess aneurysm healing. Aneurysm healing on terminal DSA was measured using a previously developed 5 point scale, with a score of 3 or 4 considered a positive outcome.
RESULTS: All animals were grouped into a single cohort for analysis as no difference in the rate of CM or healing was seen in the four treatment groups. Significant interaction between the absence of CM and a positive outcome was confirmed by Fisher exact test (P=0.0034). Angioplasty was shown to treat 33% of the cases of CM seen at implant, and these treated cases overwhelmingly had a positive outcome (P<0.001).
CONCLUSION: The use of OCT to assess CM of flow diverters has been shown to be predictive of the 30 day healing rate of an animal model of aneurysms. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

Entities:  

Keywords:  aneurysm; device; flow diverter

Mesh:

Year:  2017        PMID: 29127197     DOI: 10.1136/neurintsurg-2017-013502

Source DB:  PubMed          Journal:  J Neurointerv Surg        ISSN: 1759-8478            Impact factor:   5.836


  15 in total

1.  Optical coherence tomography: Translation from 3D-printed vascular models of the anterior cerebral circulation to the first human images of implanted surface modified flow diverters.

Authors:  Mario Martínez-Galdámez; Jorge Escartín; Boris Pabón; Carlos Diaz; Roberto Martín-Reyes; Antonio Hermosín; Eduardo Crespo; Claudio Rodríguez; Gonzalo Monedero; Krishna Joshi; Demetrius K Lopes
Journal:  Interv Neuroradiol       Date:  2018-11-05       Impact factor: 1.610

2.  Patency of anterior choroidal artery after flow diverter deployment with assessment of magnetic resonance imaging follow-up.

Authors:  Takashi Fujii; Hidenori Oishi; Kohsuke Teranishi; Kenji Yatomi; Munetaka Yamamoto; Hajime Arai
Journal:  Neuroradiol J       Date:  2018-12-03

3.  Filament inadequate wall apposition of the different ends of flow diverters in the abdominal aorta of rabbits.

Authors:  Kuizhong Wang; Peng Jin; Peigang Lu; Qiang Liu; Bo Li; Zhenqiang Hao
Journal:  Neuroradiol J       Date:  2019-11-27

4.  Intravascular Optical Coherence Tomography for Neurointerventional Surgery.

Authors:  Matthew J Gounis; Giovanni J Ughi; Miklos Marosfoi; Demetrius K Lopes; David Fiorella; Hiram G Bezerra; Conrad W Liang; Ajit S Puri
Journal:  Stroke       Date:  2018-11-29       Impact factor: 7.914

Review 5.  Optical Coherence Tomography in Cerebrovascular Disease: Open up New Horizons.

Authors:  Ran Xu; Qing Zhao; Tao Wang; Yutong Yang; Jichang Luo; Xiao Zhang; Yao Feng; Yan Ma; Adam A Dmytriw; Ge Yang; Shengpan Chen; Bin Yang; Liqun Jiao
Journal:  Transl Stroke Res       Date:  2022-04-21       Impact factor: 6.829

6.  Placement of a Stent within a Flow Diverter Improves Aneurysm Occlusion Rates.

Authors:  O Ocal; A Peker; S Balci; A Arat
Journal:  AJNR Am J Neuroradiol       Date:  2019-10-03       Impact factor: 3.825

7.  Longitudinal Monitoring of Flow-Diverting Stent Tissue Coverage After Implant in a Bifurcation Model Using Neurovascular High-Frequency Optical Coherence Tomography.

Authors:  Jildaz Caroff; Robert M King; Giovanni J Ughi; Miklos Marosfoi; Erin T Langan; Christopher Raskett; Ajit S Puri; Matthew J Gounis
Journal:  Neurosurgery       Date:  2020-11-16       Impact factor: 4.654

8.  Applications of a Novel Microangioscope for Neuroendovascular Intervention.

Authors:  V M Srinivasan; T T Lazaro; A Srivatsan; P Cooper; M Phillips; R Garcia; S R Chen; J N Johnson; J-K Burkhardt; D E Collins; P Kan
Journal:  AJNR Am J Neuroradiol       Date:  2020-12-24       Impact factor: 3.825

9.  High-resolution image-guided WEB aneurysm embolization by high-frequency optical coherence tomography.

Authors:  Zeynep Vardar; Robert M King; Afif Kraitem; Erin T Langan; Lindsy M Peterson; Benjamin H Duncan; Christopher M Raskett; Vania Anagnostakou; Matthew J Gounis; Ajit S Puri; Giovanni J Ughi
Journal:  J Neurointerv Surg       Date:  2020-09-28       Impact factor: 8.572

10.  A neurovascular high-frequency optical coherence tomography system enables in situ cerebrovascular volumetric microscopy.

Authors:  Giovanni J Ughi; Miklos G Marosfoi; Robert M King; Jildaz Caroff; Lindsy M Peterson; Benjamin H Duncan; Erin T Langan; Amanda Collins; Anita Leporati; Serge Rousselle; Demetrius K Lopes; Matthew J Gounis; Ajit S Puri
Journal:  Nat Commun       Date:  2020-07-31       Impact factor: 14.919

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.