Literature DB >> 29122816

Local Hemodynamic Forces After Stenting: Implications on Restenosis and Thrombosis.

Jaryl Ng1, Christos V Bourantas1, Ryo Torii1, Hui Ying Ang1, Erhan Tenekecioglu1, Patrick W Serruys1, Nicolas Foin2.   

Abstract

Local hemodynamic forces are well-known to modulate atherosclerotic evolution, which remains one of the largest cause of death worldwide. Percutaneous coronary interventions with stent implantation restores blood flow to the downstream myocardium and is only limited by stent failure caused by restenosis, stent thrombosis, or neoatherosclerosis. Cumulative evidence has shown that local hemodynamic forces affect restenosis and the platelet activation process, modulating the pathophysiological mechanisms that lead to stent failure. This article first covers the pathophysiological mechanisms through which wall shear stress regulates arterial disease formation/neointima proliferation and the role of shear rate on stent thrombosis. Subsequently, the article reviews the current evidence on (1) the implications of stent design on the local hemodynamic forces, and (2) how stent/scaffold expansion can influence local flow, thereby affecting the risk of adverse events.
© 2017 American Heart Association, Inc.

Entities:  

Keywords:  hemodynamics; percutaneous coronary intervention; stents; thrombosis

Mesh:

Year:  2017        PMID: 29122816     DOI: 10.1161/ATVBAHA.117.309728

Source DB:  PubMed          Journal:  Arterioscler Thromb Vasc Biol        ISSN: 1079-5642            Impact factor:   8.311


  20 in total

1.  Hemodynamic alternations following stent deployment and post-dilation in a heavily calcified coronary artery: In silico and ex-vivo approaches.

Authors:  Peshala T Gamage; Pengfei Dong; Juhwan Lee; Yazan Gharaibeh; Vladislav N Zimin; Luis A P Dallan; Hiram G Bezerra; David L Wilson; Linxia Gu
Journal:  Comput Biol Med       Date:  2021-10-21       Impact factor: 4.589

Review 2.  Disturbed flow's impact on cellular changes indicative of vascular aneurysm initiation, expansion, and rupture: A pathological and methodological review.

Authors:  Kevin Sunderland; Jingfeng Jiang; Feng Zhao
Journal:  J Cell Physiol       Date:  2021-09-06       Impact factor: 6.384

3.  Semi-Automatic Reconstruction of Patient-Specific Stented Coronaries based on Data Assimilation and Computer Aided Design.

Authors:  Adrien Lefieux; Sara Bridio; David Molony; Marina Piccinelli; Claudio Chiastra; Habib Samady; Francesco Migliavacca; Alessandro Veneziani
Journal:  Cardiovasc Eng Technol       Date:  2022-01-07       Impact factor: 2.305

4.  Preclinical comparative assessment of a dedicated pediatric poly-L-lactic-acid-based bioresorbable scaffold with a low-profile bare metal stent.

Authors:  Kamel Shibbani; Luiza De Lima E Silva Bagno; Marie-France Poulin; Thomas Matella; Karim Diab; Clifford Kavinsky; Nagarajan Ramesh; Vinayak Bhat; Ziyad M Hijazi; Damien Kenny
Journal:  Catheter Cardiovasc Interv       Date:  2020-04-15       Impact factor: 2.692

Review 5.  Bioresorbable Scaffold-Based Controlled Drug Delivery for Restenosis.

Authors:  Belay Tesfamariam
Journal:  J Cardiovasc Transl Res       Date:  2018-10-26       Impact factor: 4.132

Review 6.  Patient-Specific Modeling of Stented Coronary Arteries Reconstructed from Optical Coherence Tomography: Towards a Widespread Clinical Use of Fluid Dynamics Analyses.

Authors:  Claudio Chiastra; Susanna Migliori; Francesco Burzotta; Gabriele Dubini; Francesco Migliavacca
Journal:  J Cardiovasc Transl Res       Date:  2017-12-27       Impact factor: 4.132

7.  Screening of biopolymeric materials for cardiovascular surgery toxicity-Evaluation of their surface relief with assessment of morphological aspects of monocyte/macrophage polarization in atherosclerosis patients.

Authors:  Natalia G Menzyanova; Svetlana А Pyatina; Elena D Nikolaeva; Alexander V Shabanov; Ivan V Nemtsev; Dmitry P Stolyarov; Dmitry B Dryganov; Eugene V Sakhnov; Ekaterina I Shishatskaya
Journal:  Toxicol Rep       Date:  2018-11-16

8.  Automatic segmentation of optical coherence tomography pullbacks of coronary arteries treated with bioresorbable vascular scaffolds: Application to hemodynamics modeling.

Authors:  Marco Bologna; Susanna Migliori; Eros Montin; Rajiv Rampat; Gabriele Dubini; Francesco Migliavacca; Luca Mainardi; Claudio Chiastra
Journal:  PLoS One       Date:  2019-03-14       Impact factor: 3.240

9.  Prediction of Plaque Progression in Coronary Arteries Based on a Novel Hemodynamic Index Calculated From Virtual Stenosis Method.

Authors:  Kyung Eun Lee; Sung Woong Shin; Gook Tae Kim; Jin Ho Choi; Eun Bo Shim
Journal:  Front Physiol       Date:  2019-05-09       Impact factor: 4.566

Review 10.  The Evolution of Data Fusion Methodologies Developed to Reconstruct Coronary Artery Geometry From Intravascular Imaging and Coronary Angiography Data: A Comprehensive Review.

Authors:  Yakup Kilic; Hannah Safi; Retesh Bajaj; Patrick W Serruys; Pieter Kitslaar; Anantharaman Ramasamy; Vincenzo Tufaro; Yoshinobu Onuma; Anthony Mathur; Ryo Torii; Andreas Baumbach; Christos V Bourantas
Journal:  Front Cardiovasc Med       Date:  2020-03-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.