Literature DB >> 29122761

Effect of an Arm Traction Device on Image Quality and Radiation Exposure during Neck CT: A Prospective Study.

Y J Choi1, J H Lee2, D H Yoon3, H J Kim4, K J Seo1, K-H Do1, J H Baek1.   

Abstract

BACKGROUND AND
PURPOSE: The image quality of neck CT is frequently disturbed by streak artifact from the shoulder girdles. Our aim was to determine the effects of an arm traction device on image quality and radiation exposure in neck CT.
MATERIALS AND METHODS: Patients with lymphoma with complete remission who were scheduled to undergo 2 consecutive follow-up neck CT scans for surveillance within a 1-year interval were enrolled in this prospective study. They underwent 2 consecutive neck CT scans (intervention protocol: patients with an arm traction device; standard protocol: no positioning optimization) on the same CT system. The primary outcome measures were image noise in the lower neck and dose-length product. Secondary outcomes were streak artifacts in the supraclavicular fossa, volume CT dose index, and the extent of the biacromial line shift.
RESULTS: Seventy-three patients were enrolled and underwent 2 consecutive CT scans with a mean interval of 155 days. In the intervention protocol, a mean noise reduction in the lower neck of 25.2%-28.5% (P < .001) was achieved, and a significant decrease in dose-length product (413 versus 397, P < .001) was observed. The intervention protocol significantly decreased streak artifacts (P < .001) and volume CT dose index (13.9 versus 13.4, P < .001) and could lower the biacromial line an average of 2.1 cm.
CONCLUSIONS: An arm traction device can improve image quality and reduce radiation exposure during neck CT. The device can be simply applied in cooperative patients with suspected lower neck lesions, and the approach offers distinct advantages over the conventional imaging protocol.
© 2018 by American Journal of Neuroradiology.

Entities:  

Mesh:

Year:  2017        PMID: 29122761     DOI: 10.3174/ajnr.A5418

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  2 in total

1.  Comparison of the image quality and radiation dose of different scanning modes in head-neck CT angiography.

Authors:  Tianle Zhang; Xue Geng; Dongxue Li; Yize Xu; Yongxia Zhao
Journal:  Dentomaxillofac Radiol       Date:  2021-01-06       Impact factor: 3.525

Review 2.  2021 Korean Thyroid Imaging Reporting and Data System and Imaging-Based Management of Thyroid Nodules: Korean Society of Thyroid Radiology Consensus Statement and Recommendations.

Authors:  Eun Ju Ha; Sae Rom Chung; Dong Gyu Na; Hye Shin Ahn; Jin Chung; Ji Ye Lee; Jeong Seon Park; Roh-Eul Yoo; Jung Hwan Baek; Sun Mi Baek; Seong Whi Cho; Yoon Jung Choi; Soo Yeon Hahn; So Lyung Jung; Ji-Hoon Kim; Seul Kee Kim; Soo Jin Kim; Chang Yoon Lee; Ho Kyu Lee; Jeong Hyun Lee; Young Hen Lee; Hyun Kyung Lim; Jung Hee Shin; Jung Suk Sim; Jin Young Sung; Jung Hyun Yoon; Miyoung Choi
Journal:  Korean J Radiol       Date:  2021-10-26       Impact factor: 3.500

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.