Risk Factors for Earlier Reexposure of Glaucoma Drainage Devices.

Atalie C Thompson1, Varsha Manjunath, Kelly W Muir.   

Abstract

PURPOSE: The purpose of this study was to investigate factors associated with a second exposure of a glaucoma drainage device (GDD) following repair of an initial GDD exposure.
MATERIALS AND METHODS: This IRB-approved retrospective cohort study examined the incidence of a second exposure of a GDD following initial repair for exposure. Logistic regression was performed to assess the relationship between demographic and clinical characteristics and a second exposure of the GDD. Kaplan-Meier survival curves were plotted and Cox regression was performed to examine factors impacting the time to a second GDD exposure.
RESULTS: Ninety-four eyes of subjects that underwent initial revision for GDD exposure were reviewed. Approximately 44% (N=41/94) of subjects underwent surgical revision for a second exposure. Factors associated with reexposure in multivariate logistic regression included caucasian race (odds ratio, 2.99; P=0.02) and use of a nonscleral patch graft (odds ratio, 2.93; P=0.019). Time from revision of the initial exposure to reexposure was significantly shorter for those with a nonscleral patch graft (hazard ratio, 2.23; P=0.01) and caucasian race (hazard ratio, 2.08; P=0.04).
CONCLUSIONS: Caucasian race and use of a nonscleral patch graft during revision surgery was associated with a higher risk of experiencing a sooner reexposure of the GDD following revision of an initial exposure. Future studies should examine whether particular graft materials increase the risk of GDD reexposure.

Entities:  

Mesh:

Year:  2017        PMID: 29117009     DOI: 10.1097/IJG.0000000000000821

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  2 in total

1.  Tube Revision Outcomes for Exposure with Different Repair Techniques.

Authors:  Abeer Alawi; Ali AlBeshri; Konrad Schargel; Khabir Ahmad; Rizwan Malik
Journal:  Clin Ophthalmol       Date:  2020-10-02

2.  Electron Beam Irradiated Corneal Versus Gamma-Irradiated Scleral Patch Graft Erosion Rates in Glaucoma Drainage Device Surgery.

Authors:  Ross M Passo; Zachary B Hoskins; Khoa D Tran; Corrina Patzer; Beth Edmunds; John C Morrison; Mansi Parikh; Hana L Takusagawa; Shandiz Tehrani
Journal:  Ophthalmol Ther       Date:  2019-06-06
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.