Literature DB >> 29108632

Chorionic vascular "fit" in the human placenta: Relationship to fetoplacental outcomes.

Carolyn M Salafia1, Ruchit G Shah2, Dawn P Misra3, Jennifer K Straughen4, Drucilla J Roberts5, Larry Troxler6, Simon P Morgan7, Barbara Eucker8, John M Thorp9.   

Abstract

BACKGROUND: Novel measures of the chorionic plate and vessels are used to test the hypothesis that variation in placental structure is correlated with reduced birth weight (BW) independent of placental weight (PW), suggesting functionally compromised placentas.
METHODS: 916 mothers recruited to the Pregnancy, Infection and Nutrition Study delivering singleton live born infants at >30 gestational weeks had placentas collected, digitally photographed and weighed prior to formalin fixation. The fetal-placental weight ratio (FPR) was calculated as birthweight/placental weight. Beta (beta) was calculated as ln(PW)/ln(BW). Chorionic disk perimeter was traced and chorionic surface shape (CS) area was calculated. "Fit" was defined as the ratio of the area of the vascular to the full chorionic surface area. The sites at which chorionic vessels dived beneath the chorionic surface were marked to calculate the chorionic surface vessel (CV) area. The centroids of shapes, the distance between centroids and other measures of shape irregularities were calculated. Principal components analysis (PCA) created three independent factors. Factors were used in regression analyses to explore relations to birth weight, trimmed placental weight, FPR, and beta. Specific measures of shape irregularity were also examined in regression analyses for interrelationships and to predict birth weight, placental weight, FPR, and beta.
RESULTS: Variables related to disk size (CS area, perimeter) were correlated with BW, GA, trimmed PW and beta. "Fit" (the ratio of CV area to CS area), measures of shape irregularities, and the distance between the cord insertion and the centroids of surface and vascular areas were also correlated with one or more of the clinical outcome variables. PCA yielded three factors that had independent effects on birth weight, placental weight, the fetal-placental weight ratio, and beta (each p < 0.0001). Addition of GA did not alter the factors' associations with outcomes. Chorionic "fit" (ratio of areas), also included within the factor analysis, was a positive predictor of birth weight (p = 0.005) and FPR (p = 0.002) and a negative predictor of beta (p = 0.01). Fit was statistically significantly associated with greater distances between the umbilical cord insertion site and the CS (p < 0.001) and CV centroids (p < 0.001), and to lesser displacement between CS and CV centroids (p < 0.001).
CONCLUSIONS: Measures of CS and CV account for variation in placental efficiency defined by beta, independent of GA. Macroscopic placenta measurements can identify suboptimal placental development.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Birth weight; Chorionic plate; Placenta efficiency; Placental weight

Mesh:

Year:  2017        PMID: 29108632      PMCID: PMC5806527          DOI: 10.1016/j.placenta.2017.08.008

Source DB:  PubMed          Journal:  Placenta        ISSN: 0143-4004            Impact factor:   3.481


  33 in total

1.  The reconstruction of Kleiber's law at the organ-tissue level.

Authors:  Z Wang; T P O'Connor; S Heshka; S B Heymsfield
Journal:  J Nutr       Date:  2001-11       Impact factor: 4.798

2.  Biological scaling and physics.

Authors:  A R P Rau
Journal:  J Biosci       Date:  2002-09       Impact factor: 1.826

3.  The breadth of the placental surface but not the length is associated with body size at birth.

Authors:  S H Alwasel; Z Abotalib; J S Aljarallah; C Osmond; S Y Al Omar; A Harrath; K Thornburg; D J P Barker
Journal:  Placenta       Date:  2012-05-29       Impact factor: 3.481

4.  The relationship between human placental morphometry and ultrasonic measurements of utero-placental blood flow and fetal growth.

Authors:  N Salavati; U Sovio; R Plitman Mayo; D S Charnock-Jones; G C S Smith
Journal:  Placenta       Date:  2015-12-12       Impact factor: 3.481

5.  Shape matching algorithm to validate the tracing protocol of placental chorionic surface vessel networks.

Authors:  R G Shah; C M Salafia; T Girardi; L Conrad; K Keaty; A Bartleotc
Journal:  Placenta       Date:  2015-05-12       Impact factor: 3.481

6.  Placental surface shape, function, and effects of maternal and fetal vascular pathology.

Authors:  C M Salafia; M Yampolsky; D P Misra; O Shlakhter; D Haas; B Eucker; J Thorp
Journal:  Placenta       Date:  2010-10-08       Impact factor: 3.481

7.  Is the placental disk really an ellipse?

Authors:  M Yampolsky; C M Salafia; D P Misra; O Shlakhter; J S Gill
Journal:  Placenta       Date:  2013-02-01       Impact factor: 3.481

8.  Non-linear and gender-specific relationships among placental growth measures and the fetoplacental weight ratio.

Authors:  D P Misra; C M Salafia; R K Miller; A K Charles
Journal:  Placenta       Date:  2009-10-29       Impact factor: 3.481

9.  Sex differences in regional specialisation across the placental surface.

Authors:  S H Alwasel; A H Harrath; W M Aldahmash; Z Abotalib; J R Nyengaard; C Osmond; M R Dilworth; S Y Al Omar; A A Jerah; D J P Barker
Journal:  Placenta       Date:  2014-03-14       Impact factor: 3.481

Review 10.  The Programming Power of the Placenta.

Authors:  Amanda N Sferruzzi-Perri; Emily J Camm
Journal:  Front Physiol       Date:  2016-03-14       Impact factor: 4.566

View more
  1 in total

Review 1.  Advances in Human Placental Biomechanics.

Authors:  R Plitman Mayo
Journal:  Comput Struct Biotechnol J       Date:  2018-08-24       Impact factor: 7.271

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.