Literature DB >> 23823047

Superior versus anteroinferior plating of clavicle fractures.

Nathan Formaini1, Benjamin C Taylor, Jeffrey Backes, Thomas J Bramwell.   

Abstract

Plate fixation of displaced clavicle fractures has proven to be reliable and reproducible, leading to high union rates and a low rate of associated complications. However, the decision of whether to place the plate superiorly or anteroinferiorly on the clavicle has remained controversial. The authors performed a retrospective review on a consecutive series of patients who underwent plate fixation for a displaced midshaft clavicle fracture at a Level I urban trauma center. A review of surgical records identified 138 patients with a displaced midshaft clavicle fracture requiring operative stabilization. A total of 105 patients who met the inclusion criteria were included in the analysis. Both superior and anteroinferior techniques resulted in a similar time to radiographic union (12.6±4.8 vs 11.3±5.2 weeks, respectively) and identical union rates (95%). At final follow-up, patient-reported implant prominence was nearly double in patients with a retained superior plate (54% vs 29%, respectively; P=.04). No significant difference existed in mean visual analog scale score at a mean of 2.77 years postoperatively, although a significant difference existed in the Oxford Shoulder Score questionnaire, with a mean score of 41.4 in the superior group and 44.4 in the anteroinferior group (P=.008). Implant removal occurred more frequently after superior plating but was not significant. Both superior and anteroinferior clavicle plating are safe treatment methods for displaced clavicle fractures. Superior plating leads to an increased rate of patient-reported implant prominence and may prompt more requests for implant removal. Copyright 2013, SLACK Incorporated.

Entities:  

Mesh:

Year:  2013        PMID: 23823047     DOI: 10.3928/01477447-20130624-20

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  12 in total

1.  [Analysis of the accuracy of fit of five anatomically precontoured clavicle plate systems].

Authors:  Johannes Oppermann; Linda Ettmann; Carolin Meyer; Christian Ries; Gregor Stein; Christian Karl Spies; Lars Peter Müller; Christoph Faymonville
Journal:  Unfallchirurg       Date:  2018-06       Impact factor: 1.000

2.  [Clavicular fractures : Diagnostics, management and treatment].

Authors:  M Wurm; M Beirer; P Biberthaler; C Kirchhoff
Journal:  Unfallchirurg       Date:  2018-12       Impact factor: 1.000

3.  VA-LCP anterior clavicle plate: the anatomically precontoured fixation system with angular stability for clavicle shaft.

Authors:  G D J van Olden
Journal:  Musculoskelet Surg       Date:  2013-10-27

4.  A single centre experience of pre-contoured clavicle plates by an anterior approach.

Authors:  Eoin J Fahey; John G Galbraith; Ken Kaar
Journal:  J Orthop       Date:  2019-02-27

Review 5.  Anterior inferior plating versus superior plating for clavicle fracture: a meta-analysis.

Authors:  Jie Ai; Shun-Li Kan; Hai-Liang Li; Hong Xu; Yang Liu; Guang-Zhi Ning; Shi-Qing Feng
Journal:  BMC Musculoskelet Disord       Date:  2017-04-18       Impact factor: 2.362

6.  Superior versus anteroinferior plating of displaced midshaft clavicular fracture in patients older than 60 years.

Authors:  Minpeng Lu; Hao Qiu; Xin Zhou; Cody S Lee; Dianming Jiang; Jing Dong; Zhengxue Quan
Journal:  J Int Med Res       Date:  2017-03-21       Impact factor: 1.671

7.  Displaced midshaft clavicle fracture in athletes - should we operate?

Authors:  Neydson André Solposto Marques de Souza; Paulo Santoro Belangero; Eduardo Antônio de Figueiredo; Alberto de Casto Pochini; Carlos Vicente Andreoli; Benno Ejnisman
Journal:  Rev Bras Ortop       Date:  2018-02-15

8.  TREATMENT OF MIDSHAFT CLAVICLE FRACTURE WITH SUPERIOR PLATE PLACEMENT.

Authors:  Bekir Eray Kilinc; Yunus Oc; Ramazan Erden Erturer
Journal:  Acta Ortop Bras       Date:  2020 Mar-Apr       Impact factor: 0.513

9.  Five-Year Follow-up Results of a Randomized Controlled Study Comparing Intramedullary Nailing with Plate Fixation of Completely Displaced Midshaft Fractures of the Clavicle in Adults.

Authors:  Hendrik F S Fuglesang; Gunnar B Flugsrud; Per-Henrik Randsborg; Ola-Lars Hammer; Stein Erik Utvåg
Journal:  JB JS Open Access       Date:  2018-10-23

10.  Finite element analysis of spiral plate and Herbert screw fixation for treatment of midshaft clavicle fractures.

Authors:  Xiaojuan Zhang; Xiaodong Cheng; Bing Yin; Jianzhao Wang; Sheng Li; Guobin Liu; Zusheng Hu; Weiwei Wu; Yingze Zhang
Journal:  Medicine (Baltimore)       Date:  2019-08       Impact factor: 1.817

View more