Literature DB >> 2908900

Transpedicular screw fixation.

J M Moran1, W S Berg, J L Berry, J M Geiger, A D Steffee.   

Abstract

Spinal fixation employing transpedicular screws has recently been the focus of increased attention at various institutions throughout the world, but concerns about the safety and efficacy of transpedicular screws linger. This study was undertaken to address some of these concerns. The study included evaluation of the internal and external morphology of the vertebral pedicles, which revealed that adequate bone stock is generally available at T2, T7, T12, and L1-L5 spinal levels to accept screws in the 4-7-mm diameter range. The pedicle was observed to be composed of abundant cancellous bone internally with relatively thick cortical walls. The method of pilot hole preparation for pedicle screws was also examined. Screws inserted in pilot holes prepared with a 3.4-mm blunt probe (ganglion knife) resulted in higher pullout forces in eight of 10 trials as compared with those with pilot holes prepared using a 3.2-mm drill. Furthermore, the probes afford greater control of hole depth and alignment. Fatigue studies on three screw designs revealed a graduation of strength between a 7.0-mm pedicle screw, a 5.5-mm pedicle screw, and a modified 6.5-mm cancellous lag screw. The modified cancellous lag screw has an inherent stress riser that affected fatigue life. It was noted that extreme care must be exercised to prevent bending of the pedicle screws during implantation. If bending occurs one can expect a 50% reduction in the number of cycles to failure.

Entities:  

Mesh:

Year:  1989        PMID: 2908900     DOI: 10.1002/jor.1100070115

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  10 in total

1.  Prediction equations for human thoracic and lumbar vertebral morphometry.

Authors:  Maria E Kunkel; Hendrik Schmidt; Hans-Joachim Wilke
Journal:  J Anat       Date:  2009-12-21       Impact factor: 2.610

2.  Biomechanical testing of three newly developed transpedicular multisegmental fixation systems.

Authors:  S Eggli; F Schläpfer; M Angst; P Witschger; M Aebi
Journal:  Eur Spine J       Date:  1992-09       Impact factor: 3.134

3.  Complexity of the thoracic spine pedicle anatomy.

Authors:  M M Panjabi; J D O'Holleran; J J Crisco; R Kothe
Journal:  Eur Spine J       Date:  1997       Impact factor: 3.134

4.  Analysis of stress induced by screws in the vertebral fixation system.

Authors:  Sarah Fakher Fakhouri; Marcos Massao Shimano; Cleudmar Amaral de Araújo; Helton Luiz Aparecido Defino; Antônio Carlos Shimano
Journal:  Acta Ortop Bras       Date:  2014       Impact factor: 0.513

5.  New means in spinal pedicle hook fixation. A biomechanical evaluation.

Authors:  U Berlemann; P Cripton; L P Nolte; K Lippuner; F Schläpfer
Journal:  Eur Spine J       Date:  1995       Impact factor: 3.134

6.  Pedicles of lumbar vertebrae.

Authors:  C Maillot; R Wolfram-Gabel
Journal:  Surg Radiol Anat       Date:  1993       Impact factor: 1.246

Review 7.  Pedicle screw fixation in spinal disorders: a European view.

Authors:  N Boos; J K Webb
Journal:  Eur Spine J       Date:  1997       Impact factor: 3.134

8.  Treatment of thoracolumbar burst fractures by short-segment pedicle screw fixation using a combination of two additional pedicle screws and vertebroplasty at the level of the fracture: a finite element analysis.

Authors:  Jen-Chung Liao; Weng-Pin Chen; Hao Wang
Journal:  BMC Musculoskelet Disord       Date:  2017-06-15       Impact factor: 2.362

9.  Regional distribution of computed tomography attenuation across the lumbar endplate.

Authors:  Kazuyuki Segami; Alejandro A Espinoza Orías; Hiroe Miyamoto; Koji Kanzaki; Howard S An; Nozomu Inoue
Journal:  PLoS One       Date:  2021-10-27       Impact factor: 3.240

10.  Micro-computed tomography analysis of the lumbar pedicle wall.

Authors:  Tomoyo Y Irie; Tohru Irie; Alejandro A Espinoza Orías; Kazuyuki Segami; Norimasa Iwasaki; Howard S An; Nozomu Inoue
Journal:  PLoS One       Date:  2021-07-08       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.