Longitudinal Annular Systolic Displacement Compared to Global Strain in Normal Fetal Hearts and Those With Cardiac Abnormalities.

Greggory R DeVore1,2, Berthold Klas3, Gary Satou4, Mark Sklansky4.   

Abstract

OBJECTIVES: The purpose of this study was to compare a new technique that measures the midventricular basal-apical longitudinal diastolic and systolic lengths, computes the longitudinal displacement fractional shortening, and compares it to global strain.
METHODS: Two hundred control fetuses were examined between 20 and 40 weeks' gestation, in whom the longitudinal displacement fractional shortening was computed from end-diastolic and end-systolic lengths measured from the apex to the mid portion of the distance between the level of the basal lateral and septal walls using 2-dimnsional speckle tracking. In addition, global strain was computed using speckle tracking. A correlation analysis was used to compare the longitudinal displacement fractional shortening to global strain. The longitudinal displacement fractional shortening of the right ventricle (RV) and left ventricle (LV) was measured in 10 fetuses with heart abnormalities.
RESULTS: The longitudinal displacement fractional shortening for the RV (mean ± SD, 22.94% ± 4.73%) and LV (21.05% ± 4.21%) was independent of gestational age and other biometric growth parameters, as was global strain (RV, -22.7% ± 4.07%); LV, -22.93% ± 3.52%). The RV longitudinal displacement fractional shortening was greater than that of the LV (P < .024). The correlations between the longitudinal displacement fractional shortening and global strain were 0.95 for the RV and 0.97 for the LV. Comparing the longitudinal displacement fractional shortening and global strain in fetuses with abnormal cardiac findings showed concordant findings in 9 of 10 fetuses.
CONCLUSIONS: The RV and LV longitudinal displacement fractional shortening can be computed from 2-dimensional images of the 4-chamber view and correlated with global strain. The longitudinal displacement fractional shortening was significantly greater for the RV than the LV and was abnormal in fetuses with RV and LV cardiac abnormalities.
© 2017 by the American Institute of Ultrasound in Medicine.

Entities:  

Keywords:  annular displacement; congenital heart disease; fetal echocardiography; speckle tracking

Mesh:

Year:  2017        PMID: 29086430     DOI: 10.1002/jum.14454

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  3 in total

1.  Feasibility of 4D-Spatio Temporal Image Correlation (STIC) in the Comprehensive Assessment of the Fetal Heart Using FetalHQ®.

Authors:  Laura Nogué; Olga Gómez; Nora Izquierdo; Cristina Mula; Narcís Masoller; Josep M Martínez; Eduard Gratacós; Greggory Devore; Fàtima Crispi; Mar Bennasar
Journal:  J Clin Med       Date:  2022-03-04       Impact factor: 4.241

2.  Fetal myocardial deformation measured with two-dimensional speckle-tracking echocardiography: longitudinal prospective cohort study of 124 healthy fetuses.

Authors:  N H M van Oostrum; C M de Vet; S B Clur; D A A van der Woude; E R van den Heuvel; S G Oei; J O E H van Laar
Journal:  Ultrasound Obstet Gynecol       Date:  2022-04-06       Impact factor: 8.678

3.  Cardiac Measurements of Size and Shape in Fetuses With Absent or Reversed End-Diastolic Velocity of the Umbilical Artery and Perinatal Survival and Severe Growth Restriction Before 34 Weeks' Gestation.

Authors:  Greggory R DeVore; Percy Pacora Portella; Edgar Hernandez Andrade; Lami Yeo; Roberto Romero
Journal:  J Ultrasound Med       Date:  2020-10-30       Impact factor: 2.754

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.