Literature DB >> 29071960

[Comparison of Protective Effect of Electroacupuncture on Myocardial Ischemia Injury Between Different Acupoint Formulas in Rats].

Jun Xie1, Ze-Bin Chen1, Song Wu1, Feng-Xia Liang1, Qing Hao1, Qian Chen1, Hua Wang2.   

Abstract

OBJECTIVE: To observe the different effects of electroacupucnture of "Neiguan" (PC 6) grouping with other acupoints on myocardial ischemia (MI) injury, so as to provide evidence for clinical acupoint formulas.
METHODS: Forty Wistar male rats were randomly divided into normal, model, EA 1[bilateral "Neiguan" (PC 6), bilateral "Zusanli" (ST 36),"Guanyuan" (CV 4)], and EA 2[bilateral "Neiguan" (PC 6), bilateral "Shenmen" (HT 7), "Danzhong" (CV 17)] groups, 10 rats in each group. The MI model was established by subcutaneous injection with ISO solution(5 mL/kg), once per day for 7 days. Both EA 1 and EA 2 groups were subjected to EA (2 Hz/100 Hz, 1 mA) for 10 min before subcutaneous injection, once daily for 21 days. Electrocardiogram (ECG) was recorded after treatment. Serum cTnT was detected by biochemistry. SOD, GSH-Px and MDA in myocardial tissues of left ventricular were measured by ELISA, and the ultrastructural changes of myocardial cells in the left ventricular were observed by electron microscope.
RESULTS: Compared with the normal group, the amplitude of S-T segment and HR of ECG, cTnT and MDA contents were significantly increased in the model group (P<0.01) accompanied with seriously destroyed ultrastructure in the myocardial tissue, while SOD and GSH-Px levels were lower than those in the normal group (P<0.01). However, EA treatments reversed all the abnormal changes in the model group (P<0.05). There was no significant difference between EA 1 and EA 2 groups in the amplitude of S-T segment and HR (P>0.05); cTnT and MDA levels in the EA 1 group were lower than those in the EA 2 group (P<0.05), while SOD and GSH-Px levels were higher than those in the EA 2 group (P<0.05), accompanied with lighter degree of ultrastructure damage in the myocardial tissue in the EA 1 group.
CONCLUSIONS: EA can prevent myocardial ischemic injury, and the effect of EA 1 treatment was better than that of EA 2.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 29071960

Source DB:  PubMed          Journal:  Zhen Ci Yan Jiu        ISSN: 1000-0607


  2 in total

1.  Heart Protective Effects of Electroacupuncture in an Animal Experimental Study with Delayed Fluid Resuscitation after Hemorrhagic Shock.

Authors:  Huan Wang; Zhen Liu; Yuanshi Liu; Zhanqi Tong; Yan Qian; Liping Chen; Bin Jiang; Mingxiong Lin; Tao Yang; Lu Gao; Mingjun Chen; Daniela Litscher; Lu Wang; Gerhard Litscher
Journal:  Evid Based Complement Alternat Med       Date:  2018-04-02       Impact factor: 2.629

2.  Effect of Electroacupuncture at Wushu Acupoints of the Cardiopulmonary Meridian on the Autophagy in Rats with Acute Myocardial Ischemia.

Authors:  Chao Zhu; Shengbing Wu; Xin Wu; Meiqi Zhou; Kun Wang; Shuai Cui; Jie Zhou
Journal:  Evid Based Complement Alternat Med       Date:  2022-03-21       Impact factor: 2.629

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.