A hand-held robotic device for peripheral intravenous catheterization.

Zhuoqi Cheng1, Brian L Davies1,2, Darwin G Caldwell1, Giacinto Barresi1, Qinqi Xu3, Leonardo S Mattos1.   

Abstract

Intravenous catheterization is frequently required for numerous medical treatments. However, this process is characterized by a high failure rate, especially when performed on difficult patients such as newborns and infants. Very young patients have small veins, and that increases the chances of accidentally puncturing the catheterization needle directly through them. In this article, we present the design, development and experimental evaluation of a novel hand-held robotic device for improving the process of peripheral intravenous catheterization by facilitating the needle insertion procedure. To our knowledge, this design is the first hand-held robotic device for assisting in the catheterization insertion task. Compared to the other available technologies, it has several unique advantages such as being compact, low-cost and able to reliably detect venipuncture. The system is equipped with an electrical impedance sensor at the tip of the catheterization needle, which provides real-time measurements used to supervise and control the catheter insertion process. This allows the robotic system to precisely position the needle within the lumen of the target vein, leading to enhanced catheterization success rate. Experiments conducted to evaluate the device demonstrated that it is also effective to deskill the task. Naïve subjects achieved an average catheterization success rate of 88% on a 1.5 mm phantom vessel with the robotic device versus 12% with the traditional unassisted system. The results of this work prove the feasibility of a hand-held assistive robotic device for intravenous catheterization and show that such device has the potential to greatly improve the success rate of these difficult operations.

Entities:  

Keywords:  Hand-held robotic device; electrical impedance; pediatric catheterization; robot-assisted catheterization; venipuncture detection

Mesh:

Year:  2017        PMID: 29059005     DOI: 10.1177/0954411917737328

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  3 in total

1.  Examining the Effect of Haptic Factors for Vascular Palpation Skill Assessment Using an Affordable Simulator.

Authors:  Zhanhe Liu; Joseph Bible; Jared Wells; Deepak Vadivalagan; Ravikiran Singapogu
Journal:  IEEE Open J Eng Med Biol       Date:  2020-08-17

2.  Design and Integration of Electrical Bio-impedance Sensing in Surgical Robotic Tools for Tissue Identification and Display.

Authors:  Zhuoqi Cheng; Diego Dall'Alba; Simone Foti; Andrea Mariani; Thibaud Chupin; Darwin G Caldwell; Giancarlo Ferrigno; Elena De Momi; Leonardo S Mattos; Paolo Fiorini
Journal:  Front Robot AI       Date:  2019-07-17

3.  Retrospective Study of the Application Value Analysis of Ultrasound-Guided Technology in Peripheral Deep Venous Catheterization of Neonates.

Authors:  Tingting Yin; Yuan Huo; Yang Zhao; Weiyang Li; Hongxia Gao
Journal:  Dis Markers       Date:  2022-07-23       Impact factor: 3.464

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.