Literature DB >> 29041239

Subcutaneous veins depth measurement using diffuse reflectance images.

C M Goh, R Subramaniam, N M Saad, S A Ali, F Meriaudeau.   

Abstract

Intravenous (IV) procedures are often difficult due to the poor visualization of subcutaneous veins. Because existing vein locators lack the ability to assess depth, and also because mis-punctures and poor vascular access remain problematic, we propose an imaging system that employs diffuse reflectance images at three isosbestic wavelengths to measure both the depth and thickness of subcutaneous veins. This paper describes the proposed system as well as proof-of-principle experimental demonstrations. We initially introduce the working principle and structure of the system. All measurements were based on the Monte Carlo (MC) method and accomplished by referring an optical density (OD) ratio to a multi-layer diffuse reflectance model. Results were all validated by comparative ultrasound measurements. Experimental trials included 11 volunteers who were subjected to both ultrasound measurements and the proposed optical process to validate the system's applicability. However, the unreliability of the "thickness" measurement of the vein may be due to the fact that the veins have collapsible walls - so excess pressure by the transducer will give a false thickness.

Entities:  

Mesh:

Year:  2017        PMID: 29041239     DOI: 10.1364/OE.25.025741

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  5 in total

1.  FPGA-Based Two-Dimensional Matched Filter Design for Vein Imaging Systems.

Authors:  Wenxin Xiang; Deliang Li; Jiabing Sun; Jiawei Liu; Guowei Zhou; Yuan Gao; Xiaoyu Cui
Journal:  IEEE J Transl Eng Health Med       Date:  2021-10-14       Impact factor: 3.316

Review 2.  Vein Pattern Locating Technology for Cannulation: A Review of the Low-Cost Vein Finder Prototypes Utilizing near Infrared (NIR) Light to Improve Peripheral Subcutaneous Vein Selection for Phlebotomy.

Authors:  Cheng-Tang Pan; Mark D Francisco; Chung-Kun Yen; Shao-Yu Wang; Yow-Ling Shiue
Journal:  Sensors (Basel)       Date:  2019-08-16       Impact factor: 3.576

3.  SIMPA: an open-source toolkit for simulation and image processing for photonics and acoustics.

Authors:  Janek Gröhl; Kris K Dreher; Melanie Schellenberg; Tom Rix; Niklas Holzwarth; Patricia Vieten; Leonardo Ayala; Sarah E Bohndiek; Alexander Seitel; Lena Maier-Hein
Journal:  J Biomed Opt       Date:  2022-04       Impact factor: 3.758

4.  The "Bloodless" Blood Test: Intradermal Prick Nanoelectronics for the Blood Extraction-Free Multiplex Detection of Protein Biomarkers.

Authors:  Nimrod Harpak; Ella Borberg; Adva Raz; Fernando Patolsky
Journal:  ACS Nano       Date:  2022-08-25       Impact factor: 18.027

5.  Competitive Real-Time Near Infrared (NIR) Vein Finder Imaging Device to Improve Peripheral Subcutaneous Vein Selection in Venipuncture for Clinical Laboratory Testing.

Authors:  Mark D Francisco; Wen-Fan Chen; Cheng-Tang Pan; Ming-Cheng Lin; Zhi-Hong Wen; Chien-Feng Liao; Yow-Ling Shiue
Journal:  Micromachines (Basel)       Date:  2021-03-30       Impact factor: 2.891

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.