Use of N-acetylcysteine plus simethicone to improve mucosal visibility during upper GI endoscopy: a double-blind, randomized controlled trial.

Hugo Monrroy1, Jose Ignacio Vargas1, Esteban Glasinovic2, Roberto Candia1, Emilio Azúa3, Camila Gálvez3, Camila Rojas3, Natalia Cabrera3, Josefa Vidaurre3, Natalia Álvarez4, Jessica González4, Alberto Espino1, Robinson González1, Adolfo Parra-Blanco5.   

Abstract

BACKGROUND AND AIM: Upper GI endoscopy (UGE) is essential for the diagnosis of gastrointestinal diseases. Mucus and bubbles may decrease mucosal visibility. The use of mucolytics could improve visualization. Our aim was to determine whether premedication with simethicone or simethicone plus N-acetylcysteine is effective in improving visibility during UGE.
METHODS: This was a randomized, double-blinded, placebo-controlled trial with 2 control groups: no intervention and water 100 mL (W); and 3 intervention groups: simethicone 200 mg (S); S + N-acetylcysteine (NAC) 500 mg (S+NAC500); and S + NAC 1000 mg (S+NAC1000). The solution was ingested 20 minutes before UGE. Gastric visibility was evaluated in 4 segments with a previously described scale. A score of less than 7 points was defined as adequate visibility (AV). Water volume was used to improve visibility, and adverse reactions were evaluated as a secondary outcome. Multiple group comparison was performed using non-parametric one-way analysis of variance (ANOVA).
RESULTS: Two hundred thirty patients were included in the study, 68% female, mean age 49 years. The most common indication for UGE was epigastric pain/dyspepsia (33%). AV was more frequent in the S+NAC500 and S+NAC1000 groups (65% and 67%) compared with no intervention (44%, P = .044) and water (41%, P = .022). The gastric total visibility scale (TVS) was significantly better in the S+NAC500 and S+NAC1000 groups compared with water (P = .03 and P = .008). Simethicone was not different from no intervention and water. S+NAC1000 required less water volume to improve visibility. No adverse reactions from the study drugs were observed.
CONCLUSIONS: Premedication with S+NAC500 and S+NAC1000 improves visibility during UGE. The use of simethicone did not show improvements in gastric visibility. TVS was worse in patients using water alone. (Clinical trial registration number: NCT 01653171.).
Copyright © 2018 American Society for Gastrointestinal Endoscopy. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 29037773     DOI: 10.1016/j.gie.2017.10.005

Source DB:  PubMed          Journal:  Gastrointest Endosc        ISSN: 0016-5107            Impact factor:   9.427


  11 in total

1.  Repetitive Position Change Improves Gastric Cleanliness for Magnetically Controlled Capsule Gastroscopy.

Authors:  Yuan-Chen Wang; Jun Pan; Xi Jiang; Xiao-Ju Su; Wei Zhou; Wen-Bin Zou; Yang-Yang Qian; Yi-Zhi Chen; Xiao Liu; Jin Yu; Xiao-Nan Yan; An-Jing Zhao; Zhao-Shen Li; Zhuan Liao
Journal:  Dig Dis Sci       Date:  2018-12-17       Impact factor: 3.199

Review 2.  AGA Clinical Practice Update on the Diagnosis and Management of Atrophic Gastritis: Expert Review.

Authors:  Shailja C Shah; M Blanca Piazuelo; Ernst J Kuipers; Dan Li
Journal:  Gastroenterology       Date:  2021-08-26       Impact factor: 33.883

Review 3.  Molecular mechanisms underlying the action of carcinogens in gastric cancer with a glimpse into targeted therapy.

Authors:  Elham Patrad; Solmaz Khalighfard; Taghi Amiriani; Vahid Khori; Ali Mohammad Alizadeh
Journal:  Cell Oncol (Dordr)       Date:  2022-09-23       Impact factor: 7.051

4.  Simethicone and N-acetyl cysteine combination as premedication before esophagogastroduodenoscopy: Double-blind randomized controlled trial.

Authors:  Veeraraghavan Krishnamurthy; Abel Joseph; Shreyas Venkataraman; George Kurian
Journal:  Endosc Int Open       Date:  2022-05-13

5.  Improving the mucosal visualization at gastroscopy: a systematic review and meta-analysis of randomized, controlled trials reporting the role of Simethicone ± N-acetylcysteine.

Authors:  Muhammad Shafique Sajid; Saad Rehman; Fergus Chedgy; Krishna K Singh
Journal:  Transl Gastroenterol Hepatol       Date:  2018-05-19

Review 6.  Quality indicators in diagnostic upper gastrointestinal endoscopy.

Authors:  Wladyslaw Januszewicz; Michal F Kaminski
Journal:  Therap Adv Gastroenterol       Date:  2020-05-15       Impact factor: 4.409

7.  The effect of using simethicone with or without N-acetylcysteine before gastroscopy: A meta-analysis and systemic review.

Authors:  Yuanfa Li; Fangjuan Du; Dou Fu
Journal:  Saudi J Gastroenterol       Date:  2019 Jul-Aug       Impact factor: 2.485

Review 8.  Does Premedication with Mucolytic Agents Improve Mucosal Visualization during Oesophagogastroduodenoscopy: A Systematic Review and Meta-Analysis.

Authors:  Eoghan Burke; Patricia Harkins; Frank Moriarty; Ibrahim Ahmed
Journal:  Surg Res Pract       Date:  2021-01-22

Review 9.  Detection and Characterization of Early Gastric Cancer.

Authors:  Carlos Noronha Ferreira; Juliana Serrazina; Rui Tato Marinho
Journal:  Front Oncol       Date:  2022-07-22       Impact factor: 5.738

10.  Effect of pre-endoscopy intake of simethicone solution on endoscopic mucosal visibility: A single blinded, placebo control, randomized trial.

Authors:  Bader Faiyaz Zuberi; Majid Ahmed Shaikh; Faiza Sadaqat Ali; Tazeen Rasheed; Zunaira Nawaz
Journal:  Pak J Med Sci       Date:  2020 Jan-Feb       Impact factor: 1.088

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.