Literature DB >> 29032817

Comparison of Alterations in the Surface Topographies of HyFlex CM and HyFlex EDM Nickel-titanium Files after Root Canal Preparation: A Three-dimensional Optical Profilometry Study.

Gülşah Uslu1, Taha Özyürek2, Koray Yılmaz3.   

Abstract

AIMS: The aims of the present study were to examine the surface topographies of intact HyFlex CM and HyFlex EDM nickel-titanium files and to compare alterations in the surface topographies of these files after root canal preparation of severely curved canals of molar teeth.
METHODS: Eight HyFlex CM (25/.08) and 8 HyFlex EDM (25/.08) files were included in the present study. In total, 64 severely curved canals of molar teeth, with curvature angles ranging between 50° and 70°, were prepared with HyFlex CM and EDM (n = 32 in each group). Quantitative and qualitative analyses of the files' surface deformation were performed by using three-dimensional optical profilometry before and after root canal preparation. The data were analyzed with the Student t test at the 5% significant level by using SPSS 21.0 software.
RESULTS: In the HyFlex EDM group, the qualitative evaluation revealed the presence of cracks and microcavities after use of the file for root canal preparation, whereas only minor surface deformation was observed in the HyFlex CM group. The average roughness, root mean square roughness, and peak to valley height values of the HyFlex EDM group were significantly higher than those of the HyFlex CM group before and after root canal preparation (P < .05). The surface roughness values were statistically significantly increased in the HyFlex CM group after root canal preparation (P < .05). In contrast, the increase in the HyFlex EDM group was not statistically significant (P > .5).
CONCLUSIONS: Within the limitations of the present study, the HyFlex CM files showed significantly higher surface alterations compared with the HyFlex EDM files after the preparation of severely curved root canals.
Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  HyFlex CM; HyFlex EDM; NiTi; profilometry; surface deformation

Mesh:

Substances:

Year:  2017        PMID: 29032817     DOI: 10.1016/j.joen.2017.05.023

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  3 in total

1.  Comparison and evaluation of surface deformation of Hyflex controlled memory and Hyflex electric discharge machining nickel titanium rotary files and cyclic fatigue resistance after instrumentation and heat sterilization - An in vitro study.

Authors:  Paramarshi Das; D V Swapna; Roopa R Nadig
Journal:  J Conserv Dent       Date:  2020-08-04

2.  A new method for assessment of nickel-titanium endodontic instrument surface roughness using field emission scanning electronic microscope.

Authors:  Khoa Van Pham; Canh Quang Vo
Journal:  BMC Oral Health       Date:  2020-08-31       Impact factor: 2.757

3.  In Vitro Analysis of the Fatigue Resistance of Four Single File Canal Preparation Instruments.

Authors:  Mohammad I Al-Obaida; Abdulmohsen A Alzuwayer; Saqer S Alanazi; Abdulrahman A Balhaddad
Journal:  Materials (Basel)       Date:  2022-01-17       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.