Bleeding risk of submuscular ICD implantation with continued oral anticoagulation versus heparin bridging therapy.

Simon Pecha1, Ayhan Ayikli2, Iris Wilke3, Samer Hakmi4, Yalin Yildirim4, Nils Gosau2, Hermann Reichenspurner4, Stephan Willems2, Muhammet Ali Aydin3.   

Abstract

Recent studies have shown that subcutaneous or subfascial pacemaker- and ICD implantation with continued oral anticoagulation therapy is associated with lower risk for bleeding complications, when compared to heparin bridging strategies. However, ICD generators are often implanted submuscularly. We therefore compared the bleeding risk with continued phenprocoumon therapy vs. heparin bridging in patients receiving submuscular ICD implantation. Between 01/2013 and 12/2013, 104 patients with need for oral anticoagulation received submuscular ICD or CRT-D implantation in our institution. 46 patients were implanted under continued phenprocoumon therapy while 58 patients received heparin bridging for implantation procedure. All ICD generators were placed submuscularly. The primary outcome of the study was clinically significant bleeding or device pocket hematoma with need for surgical revision. Mean patients age was 63.7 years, 72.1% were male. In patients with heparin bridging therapy, preoperative INR prior to ICD implantation was 1.2 ± 0.31 while in the group of patients on continued phenprocoumon therapy, mean pre-OP INR was 2.4 ± 0.47. In heparin bridging group, 8 (13.8%) patients experienced a clinically relevant pocket hematoma, while only 1 (2.2%) patient on continued phenprocoumon therapy needed surgical revision for pocket hematoma (P = 0.04). No further bleeding complications or clinically relevant pericardial effusion was observed in any of the groups and no perioperative thromboembolic event occurred. Submuscular ICD implantation under continued phenprocoumon therapy was safe and feasible. Compared to patients with heparin bridging therapy, those with continued phenprocoumon therapy had a lower incidence of clinically relevant bleeding complications.

Entities:  

Keywords:  CRT-D; Heparin bridging; ICD; Oral anticoagulation; Submuscular ICD implantation

Mesh:

Substances:

Year:  2017        PMID: 29030709     DOI: 10.1007/s00380-017-1064-6

Source DB:  PubMed          Journal:  Heart Vessels        ISSN: 0910-8327            Impact factor:   2.037


  23 in total

1.  Evaluation of a new standardized protocol for the perioperative management of chronically anticoagulated patients receiving implantable cardiac arrhythmia devices.

Authors:  Oscar Cano; Begoña Muñoz; David Tejada; Joaquín Osca; María-José Sancho-Tello; José Olagüe; José E Castro; Antonio Salvador
Journal:  Heart Rhythm       Date:  2011-10-12       Impact factor: 6.343

Review 2.  Meta-analysis of bleeding complications associated with cardiac rhythm device implantation.

Authors:  Michael L Bernard; Matthew Shotwell; Paul J Nietert; Michael R Gold
Journal:  Circ Arrhythm Electrophysiol       Date:  2012-04-24

Review 3.  Oral anticoagulation continuation compared with heparin bridging therapy among high risk patients undergoing implantation of cardiac rhythm devices: a meta-analysis.

Authors:  Lei Feng; Yang Li; Jian Li; Bo Yu
Journal:  Thromb Haemost       Date:  2012-10-10       Impact factor: 5.249

4.  Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure.

Authors:  Gust H Bardy; Kerry L Lee; Daniel B Mark; Jeanne E Poole; Douglas L Packer; Robin Boineau; Michael Domanski; Charles Troutman; Jill Anderson; George Johnson; Steven E McNulty; Nancy Clapp-Channing; Linda D Davidson-Ray; Elizabeth S Fraulo; Daniel P Fishbein; Richard M Luceri; John H Ip
Journal:  N Engl J Med       Date:  2005-01-20       Impact factor: 91.245

5.  Perioperative anticoagulation management in patients on chronic oral anticoagulant therapy undergoing cardiac devices implantation: a meta-analysis.

Authors:  Ling Du; Yong Zhang; Weizong Wang; Yinglong Hou
Journal:  Pacing Clin Electrophysiol       Date:  2014-09-19       Impact factor: 1.976

6.  Perioperative Bridging Anticoagulation in Patients with Atrial Fibrillation.

Authors:  James D Douketis; Alex C Spyropoulos; Scott Kaatz; Richard C Becker; Joseph A Caprini; Andrew S Dunn; David A Garcia; Alan Jacobson; Amir K Jaffer; David F Kong; Sam Schulman; Alexander G G Turpie; Vic Hasselblad; Thomas L Ortel
Journal:  N Engl J Med       Date:  2015-06-22       Impact factor: 91.245

7.  Pocket hematoma after pacemaker or implantable cardioverter defibrillator surgery: influence of patient morbidity, operation strategy, and perioperative antiplatelet/anticoagulation therapy.

Authors:  Uwe K H Wiegand; Dominik LeJeune; Frank Boguschewski; Hendrik Bonnemeier; Frank Eberhardt; Heribert Schunkert; Frank Bode
Journal:  Chest       Date:  2004-10       Impact factor: 9.410

8.  Aesthetic subpectoral placement of implantable cardioverter defibrillators.

Authors:  Paolo Persichetti; Beniamino Brunetti; Barbara Cagli; Matteo Jacopo Manzo; Carlo Pignalberi; Gerardo Ansalone
Journal:  Ann Plast Surg       Date:  2014-02       Impact factor: 1.539

9.  Safety of pacemaker and implantable cardioverter-defibrillator implantation during uninterrupted warfarin treatment--the FinPAC study.

Authors:  K E Juhani Airaksinen; Petri Korkeila; Juha Lund; Antti Ylitalo; Pasi Karjalainen; Vesa Virtanen; Pekka Raatikainen; Ulla-Maija Koivisto; Juhani Koistinen
Journal:  Int J Cardiol       Date:  2013-07-09       Impact factor: 4.164

10.  Wound haematoma following defibrillator implantation: incidence and predictors in the Shockless Implant Evaluation (SIMPLE) trial.

Authors:  Simona Masiero; Stuart J Connolly; David Birnie; Jörg Neuzner; Stefan H Hohnloser; Xavier Vinolas; Josef Kautzner; Gilles O'Hara; Lieselot VanErven; Fredrik Gadler; Jia Wang; Philippe Mabo; Michael Glikson; Valentina Kutyifa; David J Wright; Vidal Essebag; Jeff S Healey
Journal:  Europace       Date:  2017-06-01       Impact factor: 5.214

View more