Literature DB >> 29018871

[Pacemaker, defibrillator and co : Perioperative handling of cardiac implantable electronic devices].

K Ott1, H Pressl2, M Schramm2, A Wutzl2.   

Abstract

The number of patients treated with cardiac implantable electronic devices (CIED) is continously increasing. Knowledge of the medical indications and technical mode of functioning of these devices is a basic prerequisite for the safe perioperative care of this patient cohort. The CIEDs are subjected to a multitude of disturbing influences in the perioperative setting. This can result in potentially dangerous complications, such as exit block and oversensing. The safe performance of interventions is possible as long as some basic rules are followed. An interdisciplinary approach involving all participating disciplines is necessary in order to adequately deal with the high demands placed on the logistics.

Entities:  

Keywords:  CIED; Exit block; Magnet; Oversensing; Pacemaker

Mesh:

Year:  2017        PMID: 29018871     DOI: 10.1007/s00101-017-0373-6

Source DB:  PubMed          Journal:  Anaesthesist        ISSN: 0003-2417            Impact factor:   1.041


  21 in total

1.  The revised NASPE/BPEG generic code for antibradycardia, adaptive-rate, and multisite pacing. North American Society of Pacing and Electrophysiology/British Pacing and Electrophysiology Group.

Authors:  Alan D Bernstein; Jean-Claude Daubert; Ross D Fletcher; David L Hayes; Berndt Lüderitz; Dwight W Reynolds; Mark H Schoenfeld; Richard Sutton
Journal:  Pacing Clin Electrophysiol       Date:  2002-02       Impact factor: 1.976

Review 2.  Perioperative management of patients with cardiac implantable electronic devices.

Authors:  M E Stone; B Salter; A Fischer
Journal:  Br J Anaesth       Date:  2011-12       Impact factor: 9.166

Review 3.  Creating an Anesthesiologist-run Pacemaker and Defibrillator Service: Closing the Perioperative Care Gap for These Patients.

Authors:  Marc A Rozner; Peter M Schulman
Journal:  Anesthesiology       Date:  2015-11       Impact factor: 7.892

4.  Inhibition of a pacemaker during nerve stimulation for regional anaesthesia.

Authors:  L Engelhardt; J Grosse; J Birnbaum; T Volk
Journal:  Anaesthesia       Date:  2007-10       Impact factor: 6.955

Review 5.  [Who dictates the rhythm which must be followed? : Pacemakers and implantable cardioverter defibrillators in anesthesiology].

Authors:  M Bischoff; A Walther; C Serf
Journal:  Anaesthesist       Date:  2011-08       Impact factor: 1.041

Review 6.  2017 HRS expert consensus statement on magnetic resonance imaging and radiation exposure in patients with cardiovascular implantable electronic devices.

Authors:  Julia H Indik; J Rod Gimbel; Haruhiko Abe; Ricardo Alkmim-Teixeira; Ulrika Birgersdotter-Green; Geoffrey D Clarke; Timm-Michael L Dickfeld; Jerry W Froelich; Jonathan Grant; David L Hayes; Hein Heidbuchel; Salim F Idriss; Emanuel Kanal; Rachel Lampert; Christian E Machado; John M Mandrola; Saman Nazarian; Kristen K Patton; Marc A Rozner; Robert J Russo; Win-Kuang Shen; Jerold S Shinbane; Wee Siong Teo; William Uribe; Atul Verma; Bruce L Wilkoff; Pamela K Woodard
Journal:  Heart Rhythm       Date:  2017-05-11       Impact factor: 6.343

7.  North American Society of Pacing and Electrophysiology policy statement. The NASPE/BPEG defibrillator code.

Authors:  A D Bernstein; A J Camm; J D Fisher; R D Fletcher; R H Mead; A W Nathan; V Parsonnet; A F Rickards; N P Smyth; R Sutton
Journal:  Pacing Clin Electrophysiol       Date:  1993-09       Impact factor: 1.976

Review 8.  Management of Patients With Cardiovascular Implantable Electronic Devices in Dental, Oral, and Maxillofacial Surgery.

Authors:  James Tom
Journal:  Anesth Prog       Date:  2016

Review 9.  ST-elevation myocardial infarction in the presence of biventricular paced rhythm.

Authors:  Keerthana Karumbaiah; Bassam Omar
Journal:  J Emerg Med       Date:  2013-06-12       Impact factor: 1.484

Review 10.  Magnetic resonance imaging safety in pacemaker and implantable cardioverter defibrillator patients: how far have we come?

Authors:  Peter Nordbeck; Georg Ertl; Oliver Ritter
Journal:  Eur Heart J       Date:  2015-03-21       Impact factor: 29.983

View more