[Who dictates the rhythm which must be followed? : Pacemakers and implantable cardioverter defibrillators in anesthesiology].

M Bischoff1, A Walther, C Serf.   

Abstract

The number of patients with implantable cardiac devices for the treatment of cardiac dysrhythmia is steadily climbing. Due to the increase in indications for implantation and the range of functions, an end to this development is not yet in sight. In order to provide safety in the everyday handling of these systems it is necessary to pay attention to various aspects prior to, during and after surgery or anesthesia.

Entities:  

Mesh:

Year:  2011        PMID: 21833755     DOI: 10.1007/s00101-011-1906-z

Source DB:  PubMed          Journal:  Anaesthesist        ISSN: 0003-2417            Impact factor:   1.041


  38 in total

1.  Early pacemaker twiddler syndrome.

Authors:  T Fahraeus; C J Höijer
Journal:  Europace       Date:  2003-07       Impact factor: 5.214

Review 2.  [Cardiac memory of the ECG following ventricular pacing].

Authors:  Siegfried H Recke
Journal:  Herz       Date:  2009-07-03       Impact factor: 1.443

3.  ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices): developed in collaboration with the American Association for Thoracic Surgery and Society of Thoracic Surgeons.

Authors:  Andrew E Epstein; John P DiMarco; Kenneth A Ellenbogen; N A Mark Estes; Roger A Freedman; Leonard S Gettes; A Marc Gillinov; Gabriel Gregoratos; Stephen C Hammill; David L Hayes; Mark A Hlatky; L Kristin Newby; Richard L Page; Mark H Schoenfeld; Michael J Silka; Lynne Warner Stevenson; Michael O Sweeney; Sidney C Smith; Alice K Jacobs; Cynthia D Adams; Jeffrey L Anderson; Christopher E Buller; Mark A Creager; Steven M Ettinger; David P Faxon; Jonathan L Halperin; Loren F Hiratzka; Sharon A Hunt; Harlan M Krumholz; Frederick G Kushner; Bruce W Lytle; Rick A Nishimura; Joseph P Ornato; Richard L Page; Barbara Riegel; Lynn G Tarkington; Clyde W Yancy
Journal:  Circulation       Date:  2008-05-15       Impact factor: 29.690

Review 4.  The effects of right ventricular apical pacing on ventricular function and dyssynchrony implications for therapy.

Authors:  Laurens F Tops; Martin J Schalij; Jeroen J Bax
Journal:  J Am Coll Cardiol       Date:  2009-08-25       Impact factor: 24.094

5.  Practice advisory for the perioperative management of patients with cardiac implantable electronic devices: pacemakers and implantable cardioverter-defibrillators: an updated report by the american society of anesthesiologists task force on perioperative management of patients with cardiac implantable electronic devices.

Authors: 
Journal:  Anesthesiology       Date:  2011-02       Impact factor: 7.892

6.  [Interaction of frequency-adaptive pacemakers and anesthetic management. Discussion of current literature and two case reports].

Authors:  G von Knobelsdorff; M Goerig; H Nägele; J Scholz
Journal:  Anaesthesist       Date:  1996-09       Impact factor: 1.041

7.  Strategies for the safe magnetic resonance imaging of pacemaker-dependent patients.

Authors:  J Rod Gimbel; Shane M Bailey; Patrick J Tchou; Paul M Ruggieri; Bruce L Wilkoff
Journal:  Pacing Clin Electrophysiol       Date:  2005-10       Impact factor: 1.976

8.  Acute hyperkalemia and failure of pacemaker stimulus.

Authors:  Roland N'Guetta; Nicolas Mansencal; Franck Digne; Olivier Dubourg
Journal:  Int J Cardiol       Date:  2009-09-17       Impact factor: 4.164

9.  High incidence of pacemaker syndrome in patients with sinus node dysfunction treated with ventricular-based pacing in the Mode Selection Trial (MOST).

Authors:  Mark S Link; Anne S Hellkamp; N A Mark Estes; E John Orav; Kenneth A Ellenbogen; Bassiema Ibrahim; Arnold Greenspon; Carlos Rizo-Patron; Lee Goldman; Kerry L Lee; Gervasio A Lamas
Journal:  J Am Coll Cardiol       Date:  2004-06-02       Impact factor: 24.094

10.  T-wave inversion: cardiac memory or myocardial ischemia?

Authors:  Carol Chen-Scarabelli; Tiziano M Scarabelli
Journal:  Am J Emerg Med       Date:  2009-09       Impact factor: 2.469

View more
  2 in total

Review 1.  [Anesthesiological aspects of deep brain stimulation : special features of implementation and dealing with brain pacemaker carriers].

Authors:  M Seemann; N Zech; M Lange; J Hansen; E Hansen
Journal:  Anaesthesist       Date:  2013-07       Impact factor: 1.041

2.  [Pacemaker, defibrillator and co : Perioperative handling of cardiac implantable electronic devices].

Authors:  K Ott; H Pressl; M Schramm; A Wutzl
Journal:  Anaesthesist       Date:  2017-10       Impact factor: 1.041