Literature DB >> 2899858

Near-infrared monitoring of cerebral oxygen sufficiency. I. Spectra of cytochrome c oxidase.

F F Jöbsis-VanderVliet1, C A Piantadosi, A L Sylvia, S K Lucas, H H Keizer.   

Abstract

Near-infrared (NIR) difference spectra were obtained for oxidized cytochrome c oxidase of isolated mitochondria in vitro and of cerebral tissue in situ observed through scalp and skull. The broad peaks of maximal absorption observed in both were not inconsistent with the customary assignment of an 830 nm peak. However, the ratios of the intensity of the NIR band to that of the visible peak (605 nm), which we found to be identical for in-vitro and in-situ spectra, were consistently and significantly higher than those of the various purified enzyme preparations reported in the literature. In addition the half-band widths of our in-vitro and in-situ preparations were narrower. Haemoglobin spectra in the NIR obtained in clear and in highly light-scattering media showed almost total absence of band distortion in this spectral region, suggesting that the differences observed are not due to scattering effects. Anoxia and the specific oxidase inhibitors, cyanide and carbon monoxide, caused the expected disappearance of the band in both the mitochondria in vitro and the cerebrum in situ. The 830 nm band observed in intact, well-oxygenated animal preparations was therefore identified with the NIR absorption band of oxidized cytochrome c oxidase, notwithstanding the differences with the observations on purified preparations. This points to the possibility of developing instrumentation and techniques for the non-invasive monitoring of the redox state of cytochrome c oxidase as an index to cerebral oxygen sufficiency, i.e. adequate delivery and utilization of oxygen to and by brain tissue.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 2899858     DOI: 10.1080/01616412.1988.11739809

Source DB:  PubMed          Journal:  Neurol Res        ISSN: 0161-6412            Impact factor:   2.448


  8 in total

1.  Correlated, simultaneous, multiple-wavelength optical monitoring in vivo of localized cerebrocortical NADH and brain microvessel hemoglobin oxygen saturation.

Authors:  I J Rampil; L Litt; A Mayevsky
Journal:  J Clin Monit       Date:  1992-07

Review 2.  Cerebral oxygen monitoring with near infrared spectroscopy: clinical application to neonates.

Authors:  J E Brazy
Journal:  J Clin Monit       Date:  1991-10

3.  Reflectance pulse oximetry at the forehead of newborns: the influence of varying pressure on the probe.

Authors:  A C Dassel; R Graaff; A Meijer; W G Zijlstra; J G Aarnoudse
Journal:  J Clin Monit       Date:  1996-11

4.  Comparison of 13 published cytochrome c oxidase near-infrared spectroscopy algorithms.

Authors:  R E Gagnon; F A Gagnon; A J Macnab
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1996

5.  The effect of pulsating arteries on reflectance pulse oximetry: measurements in adults and neonates.

Authors:  R Nijland; H W Jongsma; P P van den Berg; J G Nijhuis; B Oeseburg
Journal:  J Clin Monit       Date:  1995-03

Review 6.  Evaluation of intra-musclar oxygenation during exercise in humans.

Authors:  Fadɪl Ozyener
Journal:  J Sports Sci Med       Date:  2002-03-20       Impact factor: 2.988

7.  Noninvasive in vivo monitoring of cyanide toxicity and treatment using diffuse optical spectroscopy in a rabbit model.

Authors:  Jangwoen Lee; Kelly A Keuter; Jae Kim; Andrew Tran; Amit Uppal; David Mukai; Sari Brenner Mahon; Leopoldo C Cancio; Andriy Batchinsky; Bruce J Tromberg; Matthew Brenner
Journal:  Mil Med       Date:  2009-06       Impact factor: 1.437

8.  A model of brain circulation and metabolism: NIRS signal changes during physiological challenges.

Authors:  Murad Banaji; Alfred Mallet; Clare E Elwell; Peter Nicholls; Chris E Cooper
Journal:  PLoS Comput Biol       Date:  2008-11-07       Impact factor: 4.475