Flash Glucose Monitoring: Differences Between Intermittently Scanned and Continuously Stored Data.

Stefan Pleus1, Ulrike Kamecke1, Manuela Link1, Cornelia Haug1, Guido Freckmann1.   

Abstract

The flash glucose monitoring system FreeStyle Libre (Abbott Diabetes Care Ltd., Witney, UK) measures interstitial glucose concentrations and continuously stores measurement values every 15 minutes. To obtain a current glucose reading, users have to scan the sensor with the reader. In a clinical trial, 5% of the scanned data showed relative differences of more than ±10% compared with continuously stored data points (median -0.5%). Such differences might impact results of studies using this system. It should be indicated whether scanned or continuously stored data were used for analyses. Health care professionals might have to differentiate between data reports from clinical software and the scanned data their patients are provided with. Additional information on these differences and their potential impact on therapeutic decisions would be helpful.

Entities:  

Keywords:  FreeStyle Libre; continuous glucose monitoring; flash glucose monitoring; interstitial glucose

Mesh:

Substances:

Year:  2017        PMID: 28990438      PMCID: PMC5851226          DOI: 10.1177/1932296817733095

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  9 in total

1.  Novel glucose-sensing technology and hypoglycaemia in type 1 diabetes: a multicentre, non-masked, randomised controlled trial.

Authors:  Jan Bolinder; Ramiro Antuna; Petronella Geelhoed-Duijvestijn; Jens Kröger; Raimund Weitgasser
Journal:  Lancet       Date:  2016-09-12       Impact factor: 79.321

2.  Accuracy evaluation of five blood glucose monitoring systems: the North American comparator trial.

Authors:  Solveig Halldorsdottir; Mary Ellen Warchal-Windham; Jane F Wallace; Scott Pardo; Joan Lee Parkes; David A Simmons
Journal:  J Diabetes Sci Technol       Date:  2013-09-01

3.  Accuracy Evaluation of Four Blood Glucose Monitoring Systems in Unaltered Blood Samples in the Low Glycemic Range and Blood Samples in the Concentration Range Defined by ISO 15197.

Authors:  Guido Freckmann; Stefan Pleus; Manuela Link; Annette Baumstark; Christina Schmid; Josef Högel; Cornelia Haug
Journal:  Diabetes Technol Ther       Date:  2015-05-19       Impact factor: 6.118

4.  Flash Glucose Monitoring Improves Outcomes in a Type 1 Diabetes Clinic.

Authors:  Anna R Dover; Roland H Stimson; Nicola N Zammitt; Fraser W Gibb
Journal:  J Diabetes Sci Technol       Date:  2016-07-28

5.  Head-to-head comparison between flash and continuous glucose monitoring systems in outpatients with type 1 diabetes.

Authors:  B Bonora; A Maran; S Ciciliot; A Avogaro; G P Fadini
Journal:  J Endocrinol Invest       Date:  2016-06-10       Impact factor: 4.256

6.  The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System.

Authors:  Timothy Bailey; Bruce W Bode; Mark P Christiansen; Leslie J Klaff; Shridhara Alva
Journal:  Diabetes Technol Ther       Date:  2015-07-14       Impact factor: 6.118

7.  A Clinical Trial of the Accuracy and Treatment Experience of the Flash Glucose Monitor FreeStyle Libre in Adults with Type 1 Diabetes.

Authors:  Arndís F Ólafsdóttir; Stig Attvall; Ulrika Sandgren; Sofia Dahlqvist; Aldina Pivodic; Stanko Skrtic; Elvar Theodorsson; Marcus Lind
Journal:  Diabetes Technol Ther       Date:  2017-03-06       Impact factor: 6.118

8.  Performance of the FreeStyle Libre Flash glucose monitoring system in patients with type 1 and 2 diabetes mellitus.

Authors:  M J Fokkert; P R van Dijk; M A Edens; S Abbes; D de Jong; R J Slingerland; H J G Bilo
Journal:  BMJ Open Diabetes Res Care       Date:  2017-02-17

9.  Flash Glucose-Sensing Technology as a Replacement for Blood Glucose Monitoring for the Management of Insulin-Treated Type 2 Diabetes: a Multicenter, Open-Label Randomized Controlled Trial.

Authors:  Thomas Haak; Hélène Hanaire; Ramzi Ajjan; Norbert Hermanns; Jean-Pierre Riveline; Gerry Rayman
Journal:  Diabetes Ther       Date:  2016-12-20       Impact factor: 2.945

  9 in total
  6 in total

1.  Comparative Accuracy Analysis of a Real-time and an Intermittent-Scanning Continuous Glucose Monitoring System.

Authors:  Manuela Link; Ulrike Kamecke; Delia Waldenmaier; Stefan Pleus; Arturo Garcia; Cornelia Haug; Guido Freckmann
Journal:  J Diabetes Sci Technol       Date:  2019-12-17

2.  Measurement Performance of Two Continuous Tissue Glucose Monitoring Systems Intended for Replacement of Blood Glucose Monitoring.

Authors:  Guido Freckmann; Manuela Link; Stefan Pleus; Antje Westhoff; Ulrike Kamecke; Cornelia Haug
Journal:  Diabetes Technol Ther       Date:  2018-08       Impact factor: 6.118

3.  Performance of the Freestyle Libre flash glucose monitoring (flash GM) system in individuals with type 1 diabetes: A secondary outcome analysis of a randomized crossover trial.

Authors:  Othmar Moser; Max L Eckstein; Olivia McCarthy; Rachel Deere; Jason Pitt; David M Williams; Jennifer Hayes; Harald Sourij; Stephen C Bain; Richard M Bracken
Journal:  Diabetes Obes Metab       Date:  2019-08-05       Impact factor: 6.577

4.  Time in range-A1c hemoglobin relationship in continuous glucose monitoring of type 1 diabetes: a real-world study.

Authors:  Marina Valenzano; Ivan Cibrario Bertolotti; Adriano Valenzano; Giorgio Grassi
Journal:  BMJ Open Diabetes Res Care       Date:  2021-01

5.  Differences Between Flash Glucose Monitor and Fingerprick Measurements.

Authors:  Odd Martin Staal; Heidi Marie Umbach Hansen; Sverre Christian Christiansen; Anders Lyngvi Fougner; Sven Magnus Carlsen; Øyvind Stavdahl
Journal:  Biosensors (Basel)       Date:  2018-10-17

6.  The Accuracy and Precision of the Continuously Stored Data from Flash Glucose Monitoring System in Type 2 Diabetes Patients during Standard Meal Tolerance Test.

Authors:  Rengna Yan; Huiqin Li; Xiaocen Kong; Xiaofang Zhai; Maoyuan Chen; Yixuan Sun; Lei Ye; Xiaofei Su; Jianhua Ma
Journal:  Int J Endocrinol       Date:  2020-01-04       Impact factor: 3.257

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.