BACKGROUND: The use of non-sterile gloves (NSG) has become routine in the delivery of health care, often for procedures for which they are not required; their use may increase the risk of cross contamination and is generally not integrated into hand hygiene audit. This paper describes a small-scale application and validation of an observational audit tool devised to identify inappropriate use of NSG and potential for cross contamination. METHODS: Two observers simultaneously observed the use of NSG during episodes of care in an acute hospital setting. The inter-rater reliability (IRR) of the audit tool was measured corrected for chance agreement using Kappa. RESULTS: A total of 22 episodes of care using NSG were observed. In 68.6% (24/35) of procedures there was no contact with blood/body fluid; in 54.3% (19/35) NSG-use was inappropriate. The IRR was 100% for eight of 12 components of the tool. For hand hygiene before and after NSG removal it was 82% (Kappa = 0.72) and 95% (Kappa = 0.87). CONCLUSIONS: In this small-scale application of a glove-use audit tool we demonstrated over-use and misuse of NSG and potential for cross transmission on gloved hands. The audit tool provides an effective mechanism for integrating glove use into the audit of hand hygiene behaviour.
BACKGROUND: The use of non-sterile gloves (NSG) has become routine in the delivery of health care, often for procedures for which they are not required; their use may increase the risk of cross contamination and is generally not integrated into hand hygiene audit. This paper describes a small-scale application and validation of an observational audit tool devised to identify inappropriate use of NSG and potential for cross contamination. METHODS: Two observers simultaneously observed the use of NSG during episodes of care in an acute hospital setting. The inter-rater reliability (IRR) of the audit tool was measured corrected for chance agreement using Kappa. RESULTS: A total of 22 episodes of care using NSG were observed. In 68.6% (24/35) of procedures there was no contact with blood/body fluid; in 54.3% (19/35) NSG-use was inappropriate. The IRR was 100% for eight of 12 components of the tool. For hand hygiene before and after NSG removal it was 82% (Kappa = 0.72) and 95% (Kappa = 0.87). CONCLUSIONS: In this small-scale application of a glove-use audit tool we demonstrated over-use and misuse of NSG and potential for cross transmission on gloved hands. The audit tool provides an effective mechanism for integrating glove use into the audit of hand hygiene behaviour.
Keywords:
Behaviour; hand hygiene; infection control; standard precautions
Authors: H P Loveday; J A Wilson; R J Pratt; M Golsorkhi; A Tingle; A Bak; J Browne; J Prieto; M Wilcox Journal: J Hosp Infect Date: 2014-01 Impact factor: 3.926
Authors: R J Pratt; C M Pellowe; J A Wilson; H P Loveday; P J Harper; S R L J Jones; C McDougall; M H Wilcox Journal: J Hosp Infect Date: 2007-02 Impact factor: 3.926
Authors: Graham M Snyder; Kerri A Thom; Jon P Furuno; Eli N Perencevich; Mary-Claire Roghmann; Sandra M Strauss; Giora Netzer; Anthony D Harris Journal: Infect Control Hosp Epidemiol Date: 2008-07 Impact factor: 3.254
Authors: Giorgia Gon; Said M Ali; Robert Aunger; Oona M Campbell; Mícheál de Barra; Marijn de Bruin; Mohammed Juma; Stephen Nash; Amour Tajo; Johanna Westbrook; Susannah Woodd; Wendy J Graham Journal: Glob Health Sci Pract Date: 2020-12-23
Authors: Giorgia Gon; Marijn de Bruin; Mícheál de Barra; Said M Ali; Oona M Campbell; Wendy J Graham; Mohammed Juma; Stephen Nash; Claire Kilpatrick; Loveday Penn-Kekana; Sandra Virgo; Susannah Woodd Journal: Am J Infect Control Date: 2018-10-04 Impact factor: 2.918
Authors: S A Müller; A O K Diallo; R Wood; M Bayo; T Eckmanns; O Tounkara; M Arvand; M Diallo; M Borchert Journal: Antimicrob Resist Infect Control Date: 2020-05-14 Impact factor: 4.887
Authors: Eric Farfour; Marion Lecuru; Laurent Dortet; Morgan Le Guen; Charles Cerf; Françoise Karnycheff; Rémy A Bonnin; Marc Vasse; Philippe Lesprit Journal: Am J Infect Control Date: 2020-10-02 Impact factor: 2.918