PURPOSE: Artificial tear formulations typically contain a water-soluble polymer to enhance residence time, moisture retention, and binding to the mucin coat of the ocular surface, which facilitate corneal healing. This study investigated the potential advantages of combining carboxymethylcellulose (CMC) and hyaluronic acid (HA) polymers in a single formulation. MATERIALS AND METHODS: Individual CMC and HA solutions were prepared and tested for bulk viscosity in comparison to a solution that combined CMC and HA. Rheometry determined the differences between solutions at increasing shear rates, simulating eye movement and blinking. RESULTS: The bulk viscosity of the individual 0.5% CMC and 0.1% HA solutions was 2.5 and 5.7 cP, respectively. The viscosity of the combined solution (13.1 cP) was 60% higher than predicted by additive effects. Rheometry revealed shear rates between 10/second (open eye) and 10,000/second (blinking eye). At these rates, viscosity ranged from 2.7 to 3.5 cP for 0.5% CMC, 2.8 to 6.8 cP for 0.1% HA, and 5.2 to 15.3 cP for the 0.5% CMC-0.1% HA combination. Low-shear viscosity of the CMC-HA combination increased 48% over the sum of the individual solutions, but high-shear viscosity remained virtually unchanged. Data from CMC and HA solutions at higher concentrations were consistent with these results. CONCLUSION: Combining CMC and HA polymers produced a synergistic increase in low-shear viscosity (which cannot be fully explained by simple molecular entanglement), while the high-shear viscoelasticity of the combined solution remained unaffected. These data suggest that CMC-HA combinations have properties that may be used to formulate artificial tears that optimize ocular retention (through higher low-shear viscosity), while minimizing blur and stickiness during blinking (through lower high-shear viscosity).
PURPOSE: Artificial tear formulations typically contain a water-soluble polymer to enhance residence time, moisture retention, and binding to the mucin coat of the ocular surface, which facilitate corneal healing. This study investigated the potential advantages of combining carboxymethylcellulose (CMC) and hyaluronic acid (HA) polymers in a single formulation. MATERIALS AND METHODS: Individual CMC and HA solutions were prepared and tested for bulk viscosity in comparison to a solution that combined CMC and HA. Rheometry determined the differences between solutions at increasing shear rates, simulating eye movement and blinking. RESULTS: The bulk viscosity of the individual 0.5% CMC and 0.1% HA solutions was 2.5 and 5.7 cP, respectively. The viscosity of the combined solution (13.1 cP) was 60% higher than predicted by additive effects. Rheometry revealed shear rates between 10/second (open eye) and 10,000/second (blinking eye). At these rates, viscosity ranged from 2.7 to 3.5 cP for 0.5% CMC, 2.8 to 6.8 cP for 0.1% HA, and 5.2 to 15.3 cP for the 0.5% CMC-0.1% HA combination. Low-shear viscosity of the CMC-HA combination increased 48% over the sum of the individual solutions, but high-shear viscosity remained virtually unchanged. Data from CMC and HA solutions at higher concentrations were consistent with these results. CONCLUSION: Combining CMC and HA polymers produced a synergistic increase in low-shear viscosity (which cannot be fully explained by simple molecular entanglement), while the high-shear viscoelasticity of the combined solution remained unaffected. These data suggest that CMC-HA combinations have properties that may be used to formulate artificial tears that optimize ocular retention (through higher low-shear viscosity), while minimizing blur and stickiness during blinking (through lower high-shear viscosity).
Dry eye disease is a common ocular condition that has a high impact on the quality of life of affected patients, owing to discomfort and/or visual disability.1 It is a multifactorial disease associated with tear film hyperosmolarity and inflammation of the ocular surface, which can cause mild to incapacitating symptoms, such as itching, burning, blurred vision, mucous discharge, and photophobia.1–3Artificial tear solutions are the mainstay of care for patients with mild dry eye symptoms, providing relief that can minimize corneal damage. Unpreserved formulations (which reduce the risk of developing preservative-associated side effects) are also often used concomitantly with prescribed therapies in patients with moderate to severe disease.3–5 Artificial tear formulations typically contain a water-soluble polymer6 to provide enhanced residence time, retention of moisture, and binding to the mucin coat of the ocular surface, which facilitate corneal healing. Carboxymethylcellulose (CMC; also known as carmellose)7 is a polymer (Figure 1A) that has been used as an active ingredient in artificial tear solutions for many years.8 Its clinical efficacy, binding capacity to ocular surface cells, and enhancement of corneal wound healing have been demonstrated in various model systems.7,9–17 Hyaluronic acid (HA), also a polymer (Figure 1B), is used as an artificial tear ingredient because of its favorable hydrating, viscoelastic, and wound-healing properties.5,18–27 These polymers, available in a range of molecular weights representing varying chain lengths, are generally dissolved in a dilute aqueous solution for use as a lubricant eyedrop, along with appropriate excipients, such as buffers, tonicity agents, and preservatives.
Figure 1
Structure of CMC and HA.
Notes: (A) In solution, CMC forms a relatively short linear polymer (n~400); (B) compared with CMC, HA is a much longer polymer (n>5,000) that forms a random, globular coil in solution, rather than being linear.
Abbreviations: CMC, carboxymethylcellulose; HA, hyaluronic acid.
Given the distinct biochemical, biophysical, and therapeutic properties of CMC and HA, we investigated combining them in a single artificial tear formulation. We compared the properties of a formulation containing both CMC and HA with those of each polymer individually, focusing on viscosity because it can increase retention time, hence improving moisture retention and clinical outcomes.13 Multiple combinations were assessed based on concentrations of the polymers, with the goal of selecting formulas for subsequent clinical development.
Materials and methods
Solutions containing 0.5% or 1.0% CMC (low-viscosity type, approximately 90 kDa; Ashland Specialty Ingredients, Wilmington, DE, USA), 0.1%, 0.15%, or 0.25% HA (high molecular weight, >1,000 kDa; HTL Biotechnology, Javené, France), plus the combinations 0.5% CMC + 0.1% HA, 0.5% CMC + 0.15% HA, or 1.0% CMC + 0.25% HA were prepared in phosphate-buffered saline or a buffered solution (pH 7.2) containing glycerin, sodium borate, boric acid, sodium citrate, erythritol, L-carnitine, KCl, MgCl2, CaCl2, and stabilized oxychloro complex (Purite) as a preservative (similar to marketed artificial tear formulations). The solubilization process involved standard pharmaceutical methods. Briefly, buffers and tonicity agents were dissolved at moderate temperatures (40°C–50°C), and the polymers were added sequentially with rapid and sustained mixing to ensure complete dissolution. A combination of heat and filter sterilization techniques were then utilized to prepare final solutions for testing or clinical use.The viscoelastic properties of each solution were assessed at low (10/second) and high (10,000/second) shear rates (to simulate eye movement and blinking, respectively) using a programmable rheometer (AR2000; TA Instruments, New Castle, DE, USA). Measurements were taken every 60 seconds using plate and cone geometry (5° angle, 60 mm steel cone). CMC and HA solutions were also tested for bulk viscosity at a fixed shear rate (60 rpm, or approximately 79.2/second) using a Brookfield viscometer and SC4-18 spindle (Brookfield Engineering, Middleboro, MA, USA), and compared with formulations combining both CMC and HA. All measurements were performed at 25°C in ≥3 replicates.
Results
CMC and HA polymers both exhibited shear thinning (ie, viscoelastic behavior) under shear strain when analyzed individually on the rheometer. Although each polymer exhibited a characteristic curve owing to its specific molecular properties, viscosity at a given shear rate was affected by polymer concentration in both cases (Figure 2). For CMC 0.5% and 1.0%, viscosity varied from 3.5 cP (at 10/second) to 2.7 cP (at 10,000/second) and 5.8 cP (at 10/second) to 4.7 cP (at 10,000/second), respectively. For HA 0.1%, 0.15%, and 0.25%, viscosity at the same two shear rates were 6.8 and 2.8 cP, 14.4 and 3.4 cP, and 47.6 and 5.2 cP, respectively.
Figure 2
Rheological analysis of combinations of low (A), medium (B), and high (C) concentrations of CMC and HA polymers.
Notes: Data points represent mean ± standard deviation. Viscosity and shear rate are presented on a log scale.
Abbreviations: CMC, carboxymethylcellulose; HA, hyaluronic acid.
In a rheological analysis of combinations of CMC and HA polymers at 0.5% + 0.1%, 0.5% + 0.15%, and 1.0% + 0.25%, viscosity varied from 15.3 cP (at 10/second) to 5.2 cP (at 10,000/second), 25.0 cP (at 10/second) to 5.8 cP (at 10,000/second), and 127.5 cP (at 10/second) to 11.9 cP (at 10,000/second), respectively. Low (Figure 2A), medium (Figure 2B), and high (Figure 2C) concentrations of CMC and HA consistently demonstrated higher viscosity (observed values) than predicted by additive effects (theoretical values) in the 10–10,000/second shear rate range. The effect was greatest at lower levels of shear force, and decreased at higher levels. For example, the combination of 0.5% CMC and 0.1% HA had observed viscosity of 15.3 cP at 10/second, which is 48% higher than the sum of the individual polymer viscosities.Bulk viscosity measurements on the Brookfield viscometer confirmed that the viscosity of the combined solution (observed) was substantially higher than predicted (theoretical) by the sum of the individual solution viscosities. The measured value (SD) of the 0.5% CMC–0.1% HA combination was 13.1 (1.9) cP, compared with the predicted value of 8.2 cP, representing a 60% increase (Figure 3).
Figure 3
Bulk viscosity of the combined solution of 0.5% CMC and 0.1% HA was higher than predicted by additive effects.
Note: Data represent mean ± standard deviation Brookfield viscosity at 60 rpm (approximately equivalent to 79.2/second).
Abbreviations: CMC, carboxymethylcellulose; HA, hyaluronic acid.
Additional results obtained at the approximate temperature of the tear film (ie, 35°C) revealed similar properties of the combined solution at 35°C and 25°C, despite a slight reduction in absolute viscosity values.
Discussion
Consistent with published reports, rheological testing showed that, individually, CMC and HA (in their native form, not cross-linked or chemically modified) exhibit viscoelastic properties that are affected by total polymer concentration and relative shear force.28,29 In comparison, observed results were higher than expected from additive effects when testing solutions combining CMC and HA. Indeed, rheological findings indicated that this combination of polymers exhibited higher viscosity than predicted from the sum of their individual formulation values, except at the highest shear rate tested (10,000/second), suggesting a synergistic effect, or cooperative interactions, between CMC and HA. This synergy at low shear force could potentially be explained (at least in part) by the fact that the relationship between viscosity and concentration is typically logarithmic, rather than additive,30 but cannot be fully explained by simple molecule entanglement because the increase in low-shear viscosity occurs immediately upon mixing CMC and HA polymers and is readily reversible (data not shown). Both CMC and HA are anionic at physiological pH, exposing multiple hydroxyl and carboxyl water-binding sites that create a net negative charge and generate intra/interchain repulsion, thereby reducing chain–chain binding. It is this electrorepulsion that limits interactions between HA and CMC molecules to weaker, nonionic, fully reversible forces.While the high molecular weight HApolymer (>1,000 kDa) is predicted to form globular random coiled structures31 (referred to as “time-average spheres”)32 that include ions and small molecules but exclude macromolecules such as proteins,33 short/low molecular weight HA chains cannot coil and remain somewhat extended and flexible in aqueous solution.31 Similarly, the CMC polymer is not known to coil and is mostly linear/extended in solution.34 In both cases, extension occurs because electrorepulsion at adjacent anionic sites increases as the backbone bends, causing chain rigidity. It is also worth noting that the CMC polymer used in this study was significantly shorter/smaller (approximately 30 times) than the HApolymer. With a CMC:HA weight ratio of 5:1, the CMC:HA molar ratio was >100:1. Nonetheless, CMC is largely excluded from HA spheres (due to its relatively large size compared with water and ions), which likely contributes to the macromolecular interactions between the two anionic polymers and forms the basis for the observed rheological synergy.Solutes cannot occupy the same space at the same time, and their associated hydration shells may not only control a larger volume than the size of the solute itself but also behave differently than the bulk solution.35 In this “bridged matrix” model, spheres composed of individual HA molecules occupy a greater volume because of their shape and total hydration space, explaining why (at least in part) HA is responsible for the majority of the solution viscosity in the CMC–HA combination, despite the greater amount of CMC by weight and total number of molecules. These HA spheres allow relatively free movement of water, ions, and small molecules, yet exclude CMC, owing to its size and anionic repulsion forces.33,34,36 The partitioning of HA and CMC molecules, occurring to a greater degree than predicted under conditions of low shear (ie, “at rest”), may thus explain the unexpected rheological properties of the CMC–HA combination. High molecular weight HA will swell and occupy nearly all available volume at 0.1%, the concentration at which HA–HA entanglement has been reported.37 If CMC is excluded from the HA spheres, its concentration in the available space will be increased,35 and given that HA and CMC are both negatively charged, any entanglement that occurs will be limited and reversible, despite the proximity of the molecules. In this model, the excluded CMC molecules residing around the HA spheres (more so at rest) provide a stiffening component to the mixture by bridging physical forces between adjacent HA molecules.38 Under conditions of high shear force, compression and elongation of HA are expected to occur, and CMC–HA entanglement/weak binding would be broken as a consequence.The effectiveness of the CMC–HA combination at 0.5%/0.1% concentrations (Optive Fusion; Allergan plc, Dublin, Ireland) has been reported recently in two multicenter, randomized clinical trials involving patients with mild to severe dry eye.39,40 The effects of this combination on dry eye symptoms that develop after cataract surgery have also been investigated in a randomized study.41 Moreover, preservative-free and multidose preserved formulations with this combination of polymers have now become available. In these formulations, the salt content is significantly lower than in the majority of HA-based products. Osmotic balance is achieved by using organic osmolytes or other compatible solutes, without addition of sodium chloride.29,42 The reduction/absence of Na+ ions in solution increases the availability of anionic binding sites that attract and hold water, further increasing the hydration sphere around the CMC and HApolymer chains and, consequently, increasing viscosity and delivering water to the ocular surface.29,42 Increased viscosity at low shear, such as exists between blinks, should improve retention of each eyedrop instilled in the eye and thus optimize hydration and protection of the ocular surface. On the other hand, reduced viscosity at high shear, such as occurs during blinking, should improve ocular comfort and reduce symptoms of stickiness and blur associated with some eyedrop formulations. Whether formulations such as CMC 1.0% + HA 0.25% may be too concentrated for therapeutic use or better suited for nighttime treatment (when blurred vision is not a concern) remains to be determined. Overall, however, the CMC–HA combination of polymers does produce a synergistic effect that enhances its low-shear viscosity above what would be expected, allowing for greater retention on the ocular surface without increasing the total concentration of the polymers. Above a certain point, the increase in low-shear viscosity does lead to less desirable effects, as previously shown,39 and the more viscous product does not perform as well for a broad range of dry eyepatients. Therefore, an optimum formulation of the combination of CMC and HA should consider the resultant viscosity and the target patient population.
Authors: Ashley Behrens; John J Doyle; Lee Stern; Roy S Chuck; Peter J McDonnell; Dimitri T Azar; Harminder S Dua; Milton Hom; Paul M Karpecki; Peter R Laibson; Michael A Lemp; David M Meisler; Juan Murube Del Castillo; Terrence P O'Brien; Stephen C Pflugfelder; Maurizio Rolando; Oliver D Schein; Berthold Seitz; Scheffer C Tseng; Gysbert van Setten; Steven E Wilson; Samuel C Yiu Journal: Cornea Date: 2006-09 Impact factor: 2.651