Andrew Scarsbrook1,2,3, Gillian Ward4, Patrick Murray5, Rebecca Goody5, Karen Marshall6,7, Garry McDermott7,4, Robin Prestwich5, Ganesh Radhakrishna8.
Abstract
BACKGROUND: To assess the feasibility and potential impact on target delineation of respiratory-gated (4D) contrast-enhanced 18Fluorine fluorodeoxyglucose (FDG) positron emission tomography - computed tomography (PET-CT), in the treatment planning position, for a prospective cohort of patients with lower third oesophageal cancer.Entities:
Keywords: FDG pet-Ct; Four-dimensional CT; Oesophageal carcinoma; Radiotherapy treatment planning; Target volume definition
Mesh:
Substances:
Year: 2017 PMID: 28978306 PMCID: PMC5628433 DOI: 10.1186/s12885-017-3659-9
Source DB: PubMed Journal: BMC Cancer ISSN: 1471-2407 Impact factor: 4.430
Fig. 1Screenshot illustrating specialised software (RTx, Mirada Medical) used to contour 4D PET and CT datasets
Fig. 2A comparison of PTV contours derived using i) 4D CT data, ii) 4D CT co-registered to 3D PET-CT and iii) 4D CT and 4D PET
Baseline characteristics of the 7 patients studied
| Characteristic | Number |
|---|---|
| Mean age in years (range) | 71 (68–74) |
| Histology | |
|
| 6 (85.7%) |
|
| 1 (14.3%) |
| Stage (TNM) | |
| T2 N0 M0 | 2 (28.6%) |
| T3 N0 M0 | 2 (28.6%) |
| T3 N1 M0 | 2 (28.6%) |
| T3 N3 M1 | 1 (14.3%) |
| Nodal disease at baseline | |
| Yes | 3 (42.9%) |
| No | 4 (57.1%) |
| Mean primary tumour SUVmax (Range) | 12.8 (5.5–26.2) |
Volumetric and length comparison of GTV, ITV and PTV structures; there were no statistically significant differences (Mann-Whitney Test) between the volumes/lengths when comparing structures from the 3D PET-CT to the 4D CT and structures from the 4D PET-CT to the 4D CT
| Volume (cm3) | Length (cm) | |||||
|---|---|---|---|---|---|---|
| GTV | ITV | PTV | GTV | ITV | PTV | |
| 4D CT | 108.1 | 271.8 | 528.4 | 5.4 | 10.0 | 10.9 |
| 3D PET-CT | 82.6 | 239.8 | 472.5 | 6.4 | 10.1 | 11.1 |
|
| 0.89 | 0.95 | 0.95 | 0.52 | 0.8 | 0.7 |
| 4D PET-CT | 88.3 | 236.0 | 480.6 | 5.1 | 9.6 | 10.6 |
|
| 0.85 | 0.57 | 0.75 | 0.95 | 0.7 | 0.85 |
GTV gross tumour volume, ITV internal target volume, PTV planning target volume
Comparison of PTV4DCT and PTV4DPETCT structures
| Patient | DICE | Se.Idx | Inc.Idx | CGD (mm) | MDC (mm) |
|---|---|---|---|---|---|
| 1 | 0.9 | 0.91 | 0.89 | 1.73 | 5.23 |
| 2 | 0.8 | 0.74 | 0.87 | 9.25 | 12.8 |
| 3 | 0.89 | 0.85 | 0.94 | 5.19 | 11.45 |
| 4 | 0.85 | 0.79 | 0.93 | 1.64 | 10.03 |
| 5 | 0.69 | 0.65 | 0.74 | 27.29 | 22.56 |
| 6 | 0.89 | 0.92 | 0.87 | 2.9 | 5.94 |
| 7 | 0.82 | 0.77 | 0.88 | 9.33 | 10.68 |
| Median | 0.85 | 0.79 | 0.88 | 5.19 | 10.68 |
DICE Dice index, Se.Idx sensitivity index, Inc.Idx inclusiveness index, CGD centre of gravity distance, MDC mean distance to conformity, SD standard deviation
Comparison of PTV3DPET4DCT and PTV4DPETCT structures
| Patient | DICE | Se.Idx | Inc.Idx | CGD (mm) | MDC (mm) |
|---|---|---|---|---|---|
| 1 | 0.9 | 0.89 | 0.92 | 2.91 | 5.19 |
| 2 | 0.9 | 0.92 | 0.88 | 3.25 | 8.35 |
| 3 | 0.9 | 0.98 | 0.83 | 6.44 | 6.46 |
| 4 | 0.88 | 0.83 | 0.93 | 5.49 | 7.41 |
| 5 | 0.79 | 0.68 | 0.95 | 3.1 | 7.57 |
| 6 | 0.82 | 0.94 | 0.73 | 3.52 | 7.4 |
| 7 | 0.81 | 0.75 | 0.87 | 7.78 | 10.76 |
| Median | 0.88 | 0.89 | 0.88 | 3.52 | 7.41 |
DICE Dice index, Se.Idx sensitivity index, Inc.Idx inclusiveness index, CGD centre of gravity distance, MDCmean distance to conformity, SD standard deviation
Comparison of PTV4DCT and PTV3DPET4DCT structures
| Patient | DICE | Se.Idx | Inc.Idx | CGD (mm) | MDC (mm) |
|---|---|---|---|---|---|
| 1 | 0.87 | 0.9 | 0.85 | 4.02 | 5.89 |
| 2 | 0.77 | 0.7 | 0.86 | 11.23 | 15.44 |
| 3 | 0.85 | 0.76 | 0.98 | 4.97 | 10.11 |
| 4 | 0.9 | 0.88 | 0.92 | 7.03 | 9.15 |
| 5 | 0.65 | 0.72 | 0.59 | 28.17 | 22.94 |
| 6 | 0.85 | 0.78 | 0.94 | 4.19 | 6.8 |
| 7 | 0.9 | 0.91 | 0.89 | 1.61 | 5.04 |
| Median | 0.85 | 0.78 | 0.89 | 4.97 | 9.15 |
DICE Dice index, Se.Idx sensitivity index, Inc.Idx inclusiveness index, CGD centre of gravity distance, MDC mean distance to conformity, SD standard deviation
Positional metric analysis; there were no statistically significant differences (Friedman Test) between the 5 metrics comparing PTV structures between 3D PET-CT to 4D CT, 4D PET-CT to 4D CT and 3D PET-CT to 4D PET-CT
| Positional Metric | p-value |
|---|---|
| DICE | 0.62 |
| Se.Idx | 0.87 |
| Inc.Idx | 0.90 |
| CGD | 0.37 |
| MDC | 0.37 |
DICE Dice index, Se.Idx sensitivity index, Inc.Idx inclusiveness index, CGD centre of gravity distance, MDC mean distance to conformity, PTV planning target volume