Cyclotron-produced carbon-11 is a highly valuable radionuclide for the production of positron emission tomography (PET) radiotracers. It is typically produced as relatively unreactive carbon-11 carbon dioxide ([11 C]CO2 ), which is most commonly converted into a more reactive precursor for synthesis of PET radiotracers. The development of [11 C]CO2 fixation methods has more recently enabled the direct radiolabelling of a diverse array of structures directly from [11 C]CO2 , and the advantages afforded by the use of a loop-based system used in 11 C-methylation and 11 C-carboxylation reactions inspired us to apply the [11 C]CO2 fixation "in-loop." In this work, we developed and investigated a new ethylene tetrafluoroethylene (ETFE) loop-based [11 C]CO2 fixation method, enabling the fast and efficient, direct-from-cyclotron, in-loop trapping of [11 C]CO2 using mixed DBU/amine solutions. An optimised protocol was integrated into a proof-of-concept in-loop flow radiosynthesis of N,N'-[11 C]dibenzylurea. This reaction exhibited an average 78% trapping efficiency and a crude radiochemical purity of 83% (determined by radio-HPLC), giving an overall nonisolated radiochemical yield of 72% (decay-corrected) within just 3 minutes from end of bombardment. This proof-of-concept reaction has demonstrated that efficient [11 C]CO2 fixation can be achieved in a low-volume (150 μL) ETFE loop and that this can be easily integrated into a rapid in-loop flow radiosynthesis of carbon-11-labelled products. This new in-loop methodology will allow fast radiolabelling reactions to be performed using cheap/disposable ETFE tubing setup (ideal for good manufacturing practice production) thereby contributing to the widespread usage of [11 C]CO2 trapping/fixation reactions for the production of PET radiotracers.Entities:
Mesh:
Substances:
Year: 2017 PMID: 28977686 PMCID: PMC5900881 DOI: 10.1002/jlcr.3568
Source DB: PubMed Journal: J Labelled Comp Radiopharm ISSN: 0362-4803 Impact factor: 1.921
Figure 1Representative 3‐component [11C]CO2 trapping: trapping loop, vial, and [11C]CO2 trapping cartridge (ascarite)
Figure 2Effect of varying % benzylamine with fixed 10% DBU (v/v) in MeCN
Figure 3Effect of varying % DBU with fixed 10% benzylamine (v/v) in MeCN
Figure 4Schematic of in‐loop flow radiosynthetic setup showing the [11C]CO2 trapping loop as well as the additional reaction loop to allow Mitsunobu reaction to form N,N′‐[11C]dibenzylurea