Literature DB >> 28975421

Maxillary zygomatic hexagonal implant system (MZH system) for severe resorption: a new technique.

Muñoz Ruben1, Golaszewski Jose2, Diaz Alvaro2, Speranza Grace2.   

Abstract

INTRODUCTION: The biomechanical demands of the severely resorbed maxilla have prompted the search for alternative points of anchorage for zygomatic implants that allows stabilizing a prosthesis in young patients (30 years old or more) for restitution of function and form. The purpose of this study is to describe the protocol of zygomatic hexagonal implants in patients with severe maxillary bone resorption.
MATERIALS AND METHODS: Ten patients with severe maxillary resorption were treated with hexagonal implants system, they were evaluated at the preoperative and the postoperative periods for a minimal of 24 months, and the evaluation was clinical and trough conventional radiographs and CT scans. Six implants according to prosthetic prior planning were placed in each patient. Anteroposterior severely resorbed maxilla was evidence. Patients were rehabilitated with immediate provisional prosthesis. Ten days after surgery, definitive prosthesis metal structures were designed and adapted.
RESULTS: Force distribution and load concentration were balanced; adjustment of the metal bar was passive. Correction of skeletal relationship was evident. No fatigue in the later additions in controls was observable. No complications were found in the immediate postoperative period and late (6-24 months), no patients dropped out from the study, and all were followed up to 24 months.
CONCLUSIONS: The zygomatic hexagonal implants' protocol guarantees barrier function, biomechanical stability, load distribution, and preventing fatigue bone/implant interface, which allows distributing of the forces through the pillars, anterior masticatory load reduction, and correcting the skeletal class III type which occurs in patients with severe resorption.

Entities:  

Keywords:  Hexagonal systems; Reabsorbed maxilla; Zygomatic implants

Mesh:

Year:  2017        PMID: 28975421     DOI: 10.1007/s10006-017-0654-x

Source DB:  PubMed          Journal:  Oral Maxillofac Surg        ISSN: 1865-1550


  7 in total

Review 1.  Application of finite element analysis in implant dentistry: a review of the literature.

Authors:  J P Geng; K B Tan; G R Liu
Journal:  J Prosthet Dent       Date:  2001-06       Impact factor: 3.426

2.  Modified technique using multiple zygomatic implants in reconstruction of the atrophic maxilla: a technical note.

Authors:  Stefan Bothur; Goran Jonsson; Lars Sandahl
Journal:  Int J Oral Maxillofac Implants       Date:  2003 Nov-Dec       Impact factor: 2.804

3.  Anatomic site evaluation of the zygomatic bone for dental implant placement.

Authors:  Emeka Nkenke; Michael Hahn; Michael Lell; Jörg Wiltfang; Stefan Schultze-Mosgau; Beate Stech; Martin Radespiel-Tröger; Friedrich Wilhelm Neukam
Journal:  Clin Oral Implants Res       Date:  2003-02       Impact factor: 5.977

4.  Three-dimensional finite elemental analysis of zygomatic implants in craniofacial structures.

Authors:  K Ujigawa; Y Kato; Y Kizu; M Tonogi; G-Y Yamane
Journal:  Int J Oral Maxillofac Surg       Date:  2007-05-22       Impact factor: 2.789

5.  Biomechanical three-dimensional finite-element analysis of maxillary prostheses with implants. Design of number and position of implants for maxillary prostheses after hemimaxillectomy.

Authors:  S Miyamoto; K Ujigawa; Y Kizu; M Tonogi; G-Y Yamane
Journal:  Int J Oral Maxillofac Surg       Date:  2010-07-11       Impact factor: 2.789

6.  Effect of alveolar bone support on zygomatic implants: a finite element analysis study.

Authors:  M Freedman; M Ring; L F A Stassen
Journal:  Int J Oral Maxillofac Surg       Date:  2013-01-21       Impact factor: 2.789

7.  Clinical application of zygomatic implants for rehabilitation of the severely resorbed maxilla: a clinical report.

Authors:  Hidetaka Nakai; Yasuhiro Okazaki; Minoru Ueda
Journal:  Int J Oral Maxillofac Implants       Date:  2003 Jul-Aug       Impact factor: 2.804

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.