Literature DB >> 23347879

Effect of alveolar bone support on zygomatic implants: a finite element analysis study.

M Freedman1, M Ring, L F A Stassen.   

Abstract

The objective of this study was to investigate the influence of maxillary alveolar bone on the stress distribution of zygomatic implants. A three-dimensional finite element model was created of half of a skull. Two zygomatic implants were modelled, placed in the skull supported by the zygomatic bone and the maxillary alveolar bone and connected by a fixed bridge. This model was duplicated, and the area of the maxillary alveolar bone supporting the implants was removed. Occlusal and lateral forces were applied to both models and the maximum von Mises stresses were recorded. Higher maximum stresses were noted in the model with no alveolar support. Occlusal stresses were higher than lateral stresses in the model with no alveolar support. Low stresses were noted in the zygomatic bone in both models. In conclusion, maxillary alveolar bone support is beneficial in the distribution of forces for zygomatic implants.
Copyright © 2013. Published by Elsevier Ltd.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23347879     DOI: 10.1016/j.ijom.2012.12.006

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  6 in total

1.  Maxillary zygomatic hexagonal implant system (MZH system) for severe resorption: a new technique.

Authors:  Muñoz Ruben; Golaszewski Jose; Diaz Alvaro; Speranza Grace
Journal:  Oral Maxillofac Surg       Date:  2017-10-03

2.  Biomechanical 3-dimensional finite element analysis of obturator protheses retained with zygomatic and dental implants in maxillary defects.

Authors:  Canan Akay; Suat Yaluğ
Journal:  Med Sci Monit       Date:  2015-02-25

3.  Finite element analysis of 6 large PMMA skull reconstructions: A multi-criteria evaluation approach.

Authors:  Angela Ridwan-Pramana; Petr Marcián; Libor Borák; Nathaniel Narra; Tymour Forouzanfar; Jan Wolff
Journal:  PLoS One       Date:  2017-06-13       Impact factor: 3.240

4.  Stresses generated by two zygomatic implant placement techniques associated with conventional inclined anterior implants.

Authors:  Paulo H T Almeida; Sergio H Cacciacane; Fabiana M G França
Journal:  Ann Med Surg (Lond)       Date:  2018-04-21

5.  Surgical planning and finite element analysis for the neurocraneal protection in cranioplasty with PMMA: A case study.

Authors:  Freddy Patricio Moncayo-Matute; Pablo Gerardo Peña-Tapia; Efrén Vázquez-Silva; Paúl Bolívar Torres-Jara; Diana Patricia Moya-Loaiza; Gabriela Abad-Farfán; Andrés Fernando Andrade-Galarza
Journal:  Heliyon       Date:  2022-09-22

6.  Micromotion analysis of immediately loaded implants with Titanium and Cobalt-Chrome superstructures. 3D finite element analysis.

Authors:  Julio Tobar-Reyes; Luis Andueza-Castro; Antonio Jiménez-Silva; Roger Bustamante-Plaza; Juan Carvajal-Herrera
Journal:  Clin Exp Dent Res       Date:  2021-05-27
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.