Literature DB >> 28962495

Is there a role for upper-extremity intra-aortic balloon counterpulsation as a bridge-to-recovery or a bridge-to-transplant in the treatment of end-stage heart failure?

Nnamdi Nwaejike1, Andre Y Son2, Carmelo A Milano1, Mani A Daneshmand1.   

Abstract

A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was: Is there a role for upper-extremity intra-aortic balloon pump counterpulsation (UE-IABP) in the treatment of end-stage heart failure? Altogether 230 papers were found using the reported search, of which 6 papers represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. Of the 163 bridge-to-transplantation (BTT) patients, 141 (86.5%) were successfully transplanted and of the 9 bridge-to-recovery (BTR) patients, 6 (66.7%) were successfully weaned from the device. Length of support ranged from 3 to 152 days, and the most frequent complications were device malfunction or migration necessitating exchange or repositioning, occurring at a collective rate of 37.3%. UE-IABP is a minimally invasive and cost-effective strategy that provides haemodynamic support while preserving both the mediastinum and the functional status in BTR and BTT patients who may not tolerate more invasive modes of mechanical circulatory support. We conclude that UE-IABP can be used as a bridge-to-recovery (BTR) or transplant (BTT) in patients with end-stage heart failure.
© The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Entities:  

Keywords:  Bridge to recovery; Bridge to transplant; Counterpulsation; Heart failure; Intra-aortic balloon pump

Mesh:

Year:  2017        PMID: 28962495     DOI: 10.1093/icvts/ivx165

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  3 in total

Review 1.  Acute Mechanical Circulatory Support for Cardiogenic Shock.

Authors:  Kartik S Telukuntla; Jerry D Estep
Journal:  Methodist Debakey Cardiovasc J       Date:  2020 Jan-Mar

2.  Intra-Aortic Balloon Pump Bridging to Heart Transplantation: Impact of the 2018 Allocation Change.

Authors:  Lauren V Huckaby; Laura M Seese; Michael A Mathier; Gavin W Hickey; Arman Kilic
Journal:  Circ Heart Fail       Date:  2020-08-06       Impact factor: 8.790

Review 3.  Bridge to transplantation from mechanical circulatory support: a narrative review.

Authors:  Alice L Zhou; Eric W Etchill; Katherine A Giuliano; Benjamin L Shou; Kavita Sharma; Chun W Choi; Ahmet Kilic
Journal:  J Thorac Dis       Date:  2021-12       Impact factor: 2.895

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.