Literature DB >> 28962207

Whole-brain CT perfusion imaging using increased sampling intervals: A pilot study.

Guoquan Cao1, Weijian Chen1, Houzhang Sun1, Xianzhong Guo1, Yunjun Yang1, Kun Tang1, Jinjin Liu1.   

Abstract

The aim of the present study was to investigate the feasibility of whole-brain perfusion imaging using the increased sampling interval protocol for 320-detector row dynamic-volume computed tomography (CT). A total of 12 volunteers were recruited. The novel protocols with 11 volumes (defined as protocol P11) and 15 volumes (defined as protocol P15) were performed on the volunteers to evaluate whether P11 and P15 are able to acquire comparable results to the standard protocol with 19 volumes (defined as protocol P19) according to the as-low-as-reasonably-achievable principle. All data were acquired using a dynamic-volume CT scanner with a 16 cm-wide detector with 320 rows. The scanned transverse images from volunteers were analyzed using the Volume-Engineered System workstation. The MedCalc software package was used for Bland-Altman analysis of all variables. The data inconsistency of mean transit time (MTT), cerebral blood volume (CBV), cerebral blood flow (CBF), and time to peak (TTP) between P11/P15 and P19 were all <5%, and the data were trustworthy. The mean differences of MTT, CBV, CBF and TTP between P15 and P19 were less than those between P11 and P19. The consistencies of perfusion parameters acquired with protocols P15 and P19 were higher compared with those acquired with P11. In whole-brain perfusion, the new protocol P15 has higher consistency with P19 than P11, and the radiation dose may be reduced by ~16% without degradation of perfusion parameters. Therefore, P15 should be recommended as a routine procedure in whole-brain perfusion imaging.

Entities:  

Keywords:  320-detector row CT; computed tomography perfusion; radiation dose; sampling interval

Year:  2017        PMID: 28962207      PMCID: PMC5609205          DOI: 10.3892/etm.2017.4816

Source DB:  PubMed          Journal:  Exp Ther Med        ISSN: 1792-0981            Impact factor:   2.447


  16 in total

1.  Comparison of the accuracy of subtraction CT angiography performed on 320-detector row volume CT with conventional CT angiography for diagnosis of intracranial aneurysms.

Authors:  Zhuren Luo; Dan Wang; Xilin Sun; Tong Zhang; Fang Liu; Dandan Dong; Nicholas K Chan; Baozhong Shen
Journal:  Eur J Radiol       Date:  2011-05-31       Impact factor: 3.528

2.  Whole-brain perfusion CT patterns of brain arteriovenous malformations: a pilot study in 18 patients.

Authors:  D J Kim; T Krings
Journal:  AJNR Am J Neuroradiol       Date:  2011-09-01       Impact factor: 3.825

3.  Cerebral blood flow determination by rapid-sequence computed tomography: theoretical analysis.

Authors:  L Axel
Journal:  Radiology       Date:  1980-12       Impact factor: 11.105

4.  Detection of pulsation in ruptured and unruptured cerebral aneurysms by electrocardiographically gated 3-dimensional computed tomographic angiography with a 320-row area detector computed tomography and evaluation of its clinical usefulness.

Authors:  Motoharu Hayakawa; Shingo Maeda; Akiyo Sadato; Teppei Tanaka; Takafumi Kaito; Natsuki Hattori; Tsukasa Ganaha; Shigeta Moriya; Kazuhiro Katada; Kazuhiro Murayama; Yoko Kato; Yuichi Hirose
Journal:  Neurosurgery       Date:  2011-10       Impact factor: 4.654

5.  Detection and classification of cranial dural arteriovenous fistulas using 4D-CT angiography: initial experience.

Authors:  P W A Willems; P A Brouwer; J J Barfett; K G terBrugge; T Krings
Journal:  AJNR Am J Neuroradiol       Date:  2010-10-21       Impact factor: 3.825

6.  Can sufficient preoperative information of intracranial aneurysms be obtained by using 320-row detector CT angiography alone?

Authors:  Eri Hayashida; Akira Sasao; Toshinori Hirai; Kiyotoshi Hamasaki; Toru Nishi; Daisuke Utsunomiya; Seitaro Oda; Yasuhiko Iryo; Joji Urata; Yasuyuki Yamashita
Journal:  Jpn J Radiol       Date:  2013-06-16       Impact factor: 2.374

7.  Dynamic 320-section CT angiography in cranial arteriovenous shunting lesions.

Authors:  P A Brouwer; T Bosman; M A A van Walderveen; T Krings; A A Leroux; P W A Willems
Journal:  AJNR Am J Neuroradiol       Date:  2009-10-29       Impact factor: 3.825

8.  Pulsatility of an intracavernous aneurysm demonstrated by dynamic 320-detector row CTA at high temporal resolution.

Authors:  T Krings; P Willems; J Barfett; M Ellis; N Hinojosa; J Blobel; S Geibprasert
Journal:  Cent Eur Neurosurg       Date:  2009-10-22

9.  Whole brain CT perfusion in acute anterior circulation ischemia: coverage size matters.

Authors:  B J Emmer; M Rijkee; J M Niesten; M J H Wermer; B K Velthuis; M A A van Walderveen
Journal:  Neuroradiology       Date:  2014-09-17       Impact factor: 2.804

10.  The use of 4D-CTA in the diagnostic work-up of brain arteriovenous malformations.

Authors:  Peter W A Willems; Patamintita Taeshineetanakul; Barry Schenk; Patrick A Brouwer; Karel G Terbrugge; Timo Krings
Journal:  Neuroradiology       Date:  2011-04-05       Impact factor: 2.804

View more
  1 in total

1.  Effect of prolonged acquisition intervals for CT-perfusion analysis methods in patients with ischemic stroke.

Authors:  Fasco van Ommen; Frans Kauw; Edwin Bennink; Jan Willem Dankbaar; Max A Viergever; Hugo W A M de Jong
Journal:  Med Phys       Date:  2019-05-27       Impact factor: 4.071

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.