Evaluation of the Reliability and Repeatability of Scheimpflug System Measurement in Keratoconus.

Beatriz de Luis Eguileor1, Julene Escudero Argaluza2, Jose Ignacio Pijoán Zubizarreta2,3, Alaitz Santamaria Carro1, Jaime Etxebarria Ecenarro1.   

Abstract

PURPOSE: To assess the reliability and repeatability of the parameters obtained using a Scheimpflug system (Pentacam HR-high resolution) for monitoring progression in eyes with keratoconus.
METHODS: A prospective study was conducted based on measurements taken with the Pentacam HR in 82 eyes with keratoconus. We calculated the intraclass correlation coefficient (ICC) and the repeatability limit for topographic and aberrometric parameters.
RESULTS: All the parameters analyzed had excellent ICCs, above 0.95 in all cases, except for the measurement of the anterior best-fit sphere, for which the ICC was 0.873. The key repeatability limits for the parameters analyzed were as follows: 1.54 diopters (D) for the maximum keratometry in the central cornea, 1.08 D for maximum keratometry, 32.6 degrees for the axis of corneal astigmatism, 11.9 degrees for the coma axis, and 14.2 μm for thinnest corneal thickness.
CONCLUSIONS: The level of repeatability of the measurements obtained with a Pentacam HR confirms the usefulness of this system for the diagnosis of keratoconus. Nevertheless, it has certain limitations for monitoring individual progression of keratoconus and planning intrastromal corneal ring segment insertion.

Entities:  

Mesh:

Year:  2018        PMID: 28957978     DOI: 10.1097/ICO.0000000000001373

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  4 in total

1.  Prospective 2-year study of accelerated pulsed transepithelial corneal crosslinking outcomes for Keratoconus.

Authors:  Mohammed Ziaei; Hans Vellara; Akilesh Gokul; Dipika Patel; Charles N J McGhee
Journal:  Eye (Lond)       Date:  2019-07-04       Impact factor: 3.775

2.  A novel analysis of Scheimpflug total corneal refractive power following corneal cross-linking in mild to moderate keratoconus.

Authors:  Chao Pan; Wei-Na Tan; Dan Chen; Yu Liu; Hao-Yu Wang; Deng-Feng Liang; Yan-Jun Hua; Xiao-Hua Lei; Qing-Yan Zeng; Shao-Zhen Zhao
Journal:  Int J Ophthalmol       Date:  2022-05-18       Impact factor: 1.779

3.  The Pentacam® AXL Wave provides a reliable wavefront-based objective refraction when compared to manifest subjective refraction: A prospective study.

Authors:  Kepa Balparda; Andrea Acevedo-Urrego; Laura Andrea Silva-Quintero; Tatiana Herrera-Chalarca
Journal:  Indian J Ophthalmol       Date:  2022-05       Impact factor: 2.969

4.  An inter-day assessment of the ABC parameters in the evaluation of progressive keratoconus.

Authors:  Ingemar Gustafsson; Tove Faxén; André Vicente; Anders Bergström; Anders Ivarsen; Jesper Østergaard Hjortdal
Journal:  Sci Rep       Date:  2021-08-06       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.