Literature DB >> 28954243

The effects of cyclic tensile and stress-relaxation tests on porcine skin.

D Remache1, M Caliez2, M Gratton3, S Dos Santos4.   

Abstract

When a living tissue is subjected to cyclic stretching, the stress-strain curves show a shift down with the increase in the number of cycles until stabilization. This phenomenon is referred to in the literature as a preconditioning and is performed to obtain repeatable and predictable measurements. Preconditioning has been routinely performed in skin tissue tests; however, its effects on the mechanical properties of the material such as viscoelastic response, tangent modulus, sensitivity to strain rate, the stress relaxation rate, etc….remain unclear. In addition, various physical interpretations of this phenomenon have been proposed and there is no general agreement on its origin at the microscopic or mesoscopic scales. The purpose of this study was to investigate the effect of the cyclical stretching and the stress-relaxation tests on the mechanical properties of the porcine skin. Cyclic uniaxial tensile tests at large and constant strain were performed on different skin samples. The change in the reaction force, and skin's tangent modulus as a function of the number of cycles, as well as the strain rate effect on the mechanical behavior of skin samples after cycling were investigated. Stress-relaxation tests were also performed on skin samples. The change in the reaction force as a function of relaxation time and the strain rate effect on the mechanical behavior of skin samples after the stress-relaxation were investigated. The mechanical behavior of a skin sample under stress-relaxation test was modeled using a combination of hyperelasticity and viscoelasticity. Overall, the results showed that the mechanical behavior of the skin was strongly influenced by cycling and stress relaxation tests. Indeed, it was observed that the skin's resistance decreased by about half for two hours of cycling; the tangent modulus degraded by nearly 30% and skin samples became insensitive to the strain rates and accumulated progressively an inelastic deformation over time during cycling. Finally, the hysteresis loops became very narrow at the end of cycling and after relaxation process.
Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

Keywords:  Cyclic uniaxial tensile test; Damage; Mechanical skin behavior; Preconditioning; Stress-relaxation test; Viscoplastic behavior

Mesh:

Year:  2017        PMID: 28954243     DOI: 10.1016/j.jmbbm.2017.09.009

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  5 in total

1.  A method to analyze the influence of mechanical strain on dermal collagen morphologies.

Authors:  Maximilian Witte; Michael Rübhausen; Sören Jaspers; Horst Wenck; Frank Fischer
Journal:  Sci Rep       Date:  2021-04-07       Impact factor: 4.379

2.  Effect of collagen fibre orientation on the Poisson's ratio and stress relaxation of skin: an ex vivo and in vivo study.

Authors:  Krashn Kumar Dwivedi; Piyush Lakhani; Sachin Kumar; Navin Kumar
Journal:  R Soc Open Sci       Date:  2022-03-23       Impact factor: 2.963

Review 3.  Exploring the Mechanical Properties and Performance of Type-I Collagen at Various Length Scales: A Progress Report.

Authors:  Shirsha Bose; Simin Li; Elisa Mele; Vadim V Silberschmidt
Journal:  Materials (Basel)       Date:  2022-04-08       Impact factor: 3.748

4.  Experimental investigations of the human oesophagus: anisotropic properties of the embalmed mucosa-submucosa layer under large deformation.

Authors:  Ciara Durcan; Mokarram Hossain; Grégory Chagnon; Djordje Perić; Georges Karam; Lara Bsiesy; Edouard Girard
Journal:  Biomech Model Mechanobiol       Date:  2022-08-28

5.  The use of a suture retention device to enhance tissue expansion and healing in the repair of scalp and lower leg wounds.

Authors:  Collin M Blattner; Benjamin Perry; John Young; William Lear
Journal:  JAAD Case Rep       Date:  2018-08-08
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.