Literature DB >> 28952929

Unambiguous Identification and Visualization of an Acoustically Active Catheter by Ultrasound Imaging in Real Time: Theory, Algorithm, and Phantom Experiments.

Viksit Kumar, Richard Liu, Randall R Kinnick, Adriana Gregory, Azra Alizad, Marek Belohlavek, Mostafa Fatemi.   

Abstract

OBJECTIVE: Ultrasound-guided biopsies and minimally invasive procedures have been used in numerous medical applications, including catheter guidance. The biggest challenge for catheter guidance by ultrasound lies in distinguishing the catheter from neighboring tissue, as well as the ability to differentiate the catheter body from its tip.
METHODS: In our previous work, we introduced a functional prototype of an acoustically active catheter, in which a miniature piezoelectric crystal allowed accurate localization of the catheter tip by pulsed wave (PW) Doppler imaging and Doppler spectrogram. In this paper, the theory behind the symmetric Doppler shift due to the interaction of ultrasound wave with a vibrating piezoelectric crystal is explained. The theory is validated in an experimental continuous flow phantom setup. A novel algorithm, symmetric frequency detection algorithm, is presented for identification and visualization of the catheter tip in real time along with B-mode and PW Doppler.
RESULTS: The catheter tip is identified with a distinct color differentiable from common Doppler colors with a frame rate varying from 22 to 50 Hz. The catheter tip can be visualized in a small region of 2.4 mm in the elevational direction.
CONCLUSION: The algorithm can be implemented in most clinical ultrasound machines with minor additions to the PW Doppler processing algorithm. The algorithm is optimized to be robust for a variety of blood flow velocities and is shown to perform well when the signal from the blood is on par in amplitude with the catheter signal. SIGNIFICANCE: Unambiguous and distinct visualization of catheter tip facilitates real-time tracking of the catheter and aids minimally invasive procedures.

Entities:  

Mesh:

Year:  2017        PMID: 28952929      PMCID: PMC5999572          DOI: 10.1109/TBME.2017.2749245

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  15 in total

1.  Scattering of sound by sound in the vicinity of the liquid-vapor critical point.

Authors:  N Mujica; R Wunenburger; S Fauve
Journal:  Phys Rev Lett       Date:  2003-06-12       Impact factor: 9.161

2.  Experimental study of the Doppler shift generated by a vibrating scatterer.

Authors:  Régis Wunenburger; Nicolás Mujica; Stéphan Fauve
Journal:  J Acoust Soc Am       Date:  2004-02       Impact factor: 1.840

3.  A system for ultrasonic beacon-guidance of catheters and other minimally-invasive medical devices.

Authors:  D Vilkomerson; D Lyons
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1997       Impact factor: 2.725

4.  Real-time three-dimensional transoesophageal echocardiography during percutaneous transcatheter occlusion of mitral periprosthetic paravalvular leak.

Authors:  Nikola Bogunovic; Lothar Faber; Werner Scholtz; Klaus Peter Mellwig; Dieter Horstkotte; Frank van Buuren
Journal:  Eur J Echocardiogr       Date:  2011-01-14

5.  Accurate guidance of a catheter by ultrasound imaging and identification of a catheter tip by pulsed-wave Doppler.

Authors:  Eileen M McMahon; Panupong Jiamsripong; Minako Katayama; Hari P Chaliki; Mostafa Fatemi; Marek Belohlavek
Journal:  Pacing Clin Electrophysiol       Date:  2011-11-06       Impact factor: 1.976

6.  Theory of ultrasound Doppler-spectra velocimetry for arbitrary beam and flow configurations.

Authors:  D Censor; V L Newhouse; T Vontz; H V Ortega
Journal:  IEEE Trans Biomed Eng       Date:  1988-09       Impact factor: 4.538

7.  The transponder system: a new method of precise catheter placement in the right atrium under echocardiographic guidance.

Authors:  J S Landzberg; J O Franklin; J J Langberg; J M Herre; M M Scheinman; N B Schiller
Journal:  J Am Coll Cardiol       Date:  1988-09       Impact factor: 24.094

Review 8.  Diagnostic and prognostic value of 3D NOGA mapping in ischemic heart disease.

Authors:  Mariann Gyöngyösi; Nabil Dib
Journal:  Nat Rev Cardiol       Date:  2011-05-17       Impact factor: 32.419

9.  Evaluation of left ventricular volumes and ejection fraction with a nonfluoroscopic endoventricular three-dimensional mapping technique.

Authors:  G Van Langenhove; J N Hamburger; P C Smits; M Albertal; E Onderwater; I P Kay; P W Serruys
Journal:  Am Heart J       Date:  2000-10       Impact factor: 4.749

10.  Localization of needle tip with color doppler during pericardiocentesis: In vitro validation and initial clinical application.

Authors:  G Armstrong; L Cardon; D Vilkomerson; D Lipson; J Wong; L L Rodriguez; J D Thomas; B P Griffin
Journal:  J Am Soc Echocardiogr       Date:  2001-01       Impact factor: 5.251

View more
  3 in total

1.  Real-Time Visualization of an Acoustically Active Injection Catheter With Ultrasound Imaging: Algorithm and In Vivo Validation in a Swine Model.

Authors:  Viksit Kumar; Minako Katayama; Rachael Peavler; Azra Alizad; Marek Belohlavek; Mostafa Fatemi
Journal:  IEEE Trans Biomed Eng       Date:  2019-03-01       Impact factor: 4.538

2.  A Real-time Color Doppler Marker for Echocardiographic Guidance of an Acoustically Active Extracorporeal Membrane Oxygenation Cannula.

Authors:  Marek Belohlavek; Minako Katayama; Veronica V Vaitkus; Viksit Kumar; Mostafa Fatemi; Jason Grabham; Bryan Sandweiss
Journal:  J Ultrasound Med       Date:  2018-11-12       Impact factor: 2.153

3.  Gap-filling method for suppressing grating lobes in ultrasound imaging: Experimental study with deep-learning approach.

Authors:  Viksit Kumar; Po-Yang Lee; Bae-Hyung Kim; Mostafa Fatemi; Azra Alizad
Journal:  IEEE Access       Date:  2020-04-21       Impact factor: 3.367

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.