Literature DB >> 28951636

Management of unstable pertrochanteric fractures with proximal femoral locking compression plates and affect of neck-shaft angle on functional outcomes.

Emrah Kovalak1, Cenk Ermutlu2, Tolga Atay1, Özgür Başal1.   

Abstract

BACKGROUND: Management of unstable pertrochanteric fractures remains a challenge with various implant choices. Intramedullary devices are usually preferred for the management of the unstable fractures. When nailing is unsuitable for the configuration of the fracture extra medullary procedures are preferred. PFLCP is a contact limited implant that allows multiple angularly stable fixations with preserving more bone stock after implantation as an extramedullary implant. There are only a few reports in the literature about the osteosynthesis of unstable trochanteric fractures with proximal femoral locking compression plates and their results are conflicting. In the present study we aimed to evaluate the functional and radiological outcomes of proksimal femoral locking compression plates in open reduction and internal fixation of AO/OTA 31A2-2 and 3 fractures.
METHODS: Patients older than 18 years of age with a minimum follow-up time of 1 year matching the inclusion criteria retrospectively evaluated. Patients' demographics, Singh index, intra and post-operative data, mobilization and union time gathered from the patients' files. Baumgaertner modified criteria of fracture reduction was used to assess the post-operative reduction quality. Early and last follow-up radiographs were used to evaluate malunion and change in neck- shaft angle. Final clinical outcome was assessed using the Harris Hip scoring system.
RESULTS: 18 male and 13 female patients with the mean age of 74 (46-88) met the inclusion criteria. Reduction quality according to Baumgaertner modified criteria was good in 25 patients and acceptable in 6. Mean union time was 21.53 ± 4.18 weeks. There was neither non-union nor malunion. The mean neck-shaft angle change was -3.1° ± 2.16°. The mean HHS was 77.90 ± 4.84 and there was no significance in HHS according to reduction quality and change in neck-shaft angle (p = 0.385, p = 0.0059). HHS was negatively correlated with age, mobilization time and, longer union time (p < 0.05). There was no correlation between Singh index and reduction quality (p = 0.865). Singh index was only correlated with the patient's age (p = 0.000, rho = -0.595). There were 2 infections and, 2 backing of the proximal screws.
CONCLUSION: Even though PFLCP is not the first choice in management of unstable pertrochanteric fractures, it must be kept in mind as an alternative to the other conventional plates and intramedullary implants with the properties of an increased stability by multiaxial screw locking and the results are satisfactory when appropriate settlement achieved.

Entities:  

Keywords:  Hip fractures; Locking compression plate; Pertrochanteric fracture; Proximal femoral locking compression plate; Unstable intertrochanteric fracture

Year:  2017        PMID: 28951636      PMCID: PMC5605743          DOI: 10.1016/j.jcot.2017.07.006

Source DB:  PubMed          Journal:  J Clin Orthop Trauma        ISSN: 0976-5662


  27 in total

1.  Is helical blade nailing superior to locked minimally invasive plating in unstable pertrochanteric fractures?

Authors:  Matthias Knobe; Wolf Drescher; Nicole Heussen; Richard Martin Sellei; Hans-Christoph Pape
Journal:  Clin Orthop Relat Res       Date:  2012-02-07       Impact factor: 4.176

2.  A comparison of proximal femoral locking plate versus 95-degree angled blade plate in the treatment of reverse intertrochanteric fractures.

Authors:  Ibrahim Azboy; Abdullah Demirtaş; Mehmet Gem; Idris Ahmet Cakır; Yılmaz Tutak
Journal:  Eklem Hastalik Cerrahisi       Date:  2014

3.  Reverse LISS plates for unstable proximal femoral fractures.

Authors:  Ching-Hou Ma; Yuan-Kun Tu; Shang-Won Yu; Cheng-Yo Yen; Jih-Hsi Yeh; Chin-Hsien Wu
Journal:  Injury       Date:  2010-05-14       Impact factor: 2.586

4.  Treatment of pertrochanteric fractures with a proximal femur locking compression plate.

Authors:  Guo-Chun Zha; Ze-Lin Chen; Xiao-Bo Qi; Jun-Ying Sun
Journal:  Injury       Date:  2011-02-26       Impact factor: 2.586

5.  Proximal femoral locking compression plate for proximal femoral fractures.

Authors:  Wei Ting Lee; Diarmuid Murphy; Fareed H Y Kagda; Joseph Thambiah
Journal:  J Orthop Surg (Hong Kong)       Date:  2014-12       Impact factor: 1.118

6.  What is the underlying mechanism for the failure mode observed in the proximal femoral locking compression plate? A biomechanical study.

Authors:  Kerstin Schneider; Jong-Keon Oh; Ivan Zderic; Karl Stoffel; R Geoff Richards; Stefan Wolf; Boyko Gueorguiev; Sean E Nork
Journal:  Injury       Date:  2015-05-21       Impact factor: 2.586

7.  Evaluation of proximal femoral locking plate in unstable extracapsular proximal femoral fractures: Surgical technique & mid term follow up results.

Authors:  Nishikant Kumar; Himanshu Kataria; Chandrashekhar Yadav; Bharath S Gadagoli; Rishi Raj
Journal:  J Clin Orthop Trauma       Date:  2014-09-10

8.  The lateral trochanteric wall: a key element in the reconstruction of unstable pertrochanteric hip fractures.

Authors:  Y Gotfried
Journal:  Clin Orthop Relat Res       Date:  2004-08       Impact factor: 4.176

Review 9.  A review of locking compression plate biomechanics and their advantages as internal fixators in fracture healing.

Authors:  Danielle L Miller; Tarun Goswami
Journal:  Clin Biomech (Bristol, Avon)       Date:  2007-09-27       Impact factor: 2.063

10.  Proximal femoral nail versus dynamic hip screw fixation for trochanteric fractures: a meta-analysis of randomized controlled trials.

Authors:  Xiao Huang; Frankie Leung; Zhou Xiang; Pei-Yong Tan; Jing Yang; Dai-Qing Wei; Xi Yu
Journal:  ScientificWorldJournal       Date:  2013-02-19
View more
  2 in total

1.  Functional and Radiological Outcomes of Unstable Proximal Femur Fractures Fixed With Anatomical Proximal Locking Compression Plate.

Authors:  Vamsee Krishna; Aakaash Venkatesan; Ayush Kumar Singh
Journal:  Cureus       Date:  2022-05-11

2.  Controlled study on Gamma nail and proximal femoral locking plate for unstable intertrochanteric femoral fractures with broken lateral wall.

Authors:  Lei Han; Jing-Jing Liu; Yun-Gen Hu; Ren-Fu Quan; Wei-Li Fang; Bo Jin; Wei-Long Lin
Journal:  Sci Rep       Date:  2018-07-24       Impact factor: 4.379

  2 in total