Literature DB >> 24650379

A comparison of proximal femoral locking plate versus 95-degree angled blade plate in the treatment of reverse intertrochanteric fractures.

Ibrahim Azboy1, Abdullah Demirtaş, Mehmet Gem, Idris Ahmet Cakır, Yılmaz Tutak.   

Abstract

OBJECTIVES: This study aims to compare the results of the proximal femoral locking plate (PFLP) and the 95°-angled blade plate in the treatment of AO/OTA 31-A3 reverse intertrochanteric fractures with fracture line extending to the greater trochanter. PATIENTS AND METHODS: Forty-four patients with reverse intertrochanteric fracture which fracture line extending to the greater trochanter were retrospectively analyzed. Of those, 20 were treated with PFLP (PFLP group) and 24 were treated with ABP (ABP group). The AO/OTA classification was used for the classification of the fractures. Patients were assessed clinically and radiologically for the union at the fracture site and implant-related complications. Hip functions were evaluated with the Harris hip score.
RESULTS: The mean time to union was 17 weeks (range 14-28) and 18 weeks (range 16-32) in the PFLP group and ABP group, respectively. Implant failure and/or nonunion was observed in two patients (10%) in the PFLP group and in three patients (12%) in the ABP group. There was no statistically significant difference between the groups with regard to the Harris hip scores, time to union, need for reoperation due to mechanical problems, and complication rates (p>0.05).
CONCLUSION: Our study results show that these two fixation methods seem to produce similar results in the treatment of reverse intertrochanteric fractures with greater trochanteric comminution. However, we suggest that ABP still remains as a good choice with less expense in such fractures.

Entities:  

Mesh:

Year:  2014        PMID: 24650379     DOI: 10.5606/ehc.2014.04

Source DB:  PubMed          Journal:  Eklem Hastalik Cerrahisi


  5 in total

1.  Management of unstable pertrochanteric fractures with proximal femoral locking compression plates and affect of neck-shaft angle on functional outcomes.

Authors:  Emrah Kovalak; Cenk Ermutlu; Tolga Atay; Özgür Başal
Journal:  J Clin Orthop Trauma       Date:  2017-07-15

2.  Numerical Optimization of the Position in Femoral Head of Proximal Locking Screws of Proximal Femoral Nail System; Biomechanical Study.

Authors:  Mehmet Nuri Konya; Özgür Verim
Journal:  Balkan Med J       Date:  2017-04-06       Impact factor: 2.021

3.  Clinical and radiological results of using proximal femoral locking compression plate and proximal femoral nail antirotation for subtrochanteric fractures.

Authors:  Mehryar Khadem; Ali Torkaman; Karim Pisoudeh; Milad Bahari; Parsa Torkaman
Journal:  Eur J Transl Myol       Date:  2022-05-12

Review 4.  Poor relation between biomechanical and clinical studies for the proximal femoral locking compression plate.

Authors:  Bjarke Viberg; Katrine M V Rasmussen; Søren Overgaard; Cecilia Rogmark
Journal:  Acta Orthop       Date:  2017-03-13       Impact factor: 3.717

5.  Total hip arthroplasty for intertrochanteric fracture fixation failure.

Authors:  Liyun Liu; Yongqiang Sun; Linlin Wang; Qiankun Gao; Ang Li; Jialin Wang; Yanzheng Gao
Journal:  Eur J Med Res       Date:  2019-12-27       Impact factor: 2.175

  5 in total