Literature DB >> 28944372

Accuracy of digital implant impressions with intraoral scanners. A systematic review.

Vygandas Rutkūnas, Agnė Gečiauskaitė, Darius Jegelevičius, Mantas Vaitiekūnas.   

Abstract

AIM: The use of intraoral scanners (IOS) for making digital implant impressions is increasing. However, there is a lack of evidence on the accuracy of IOS compared with conventional techniques. Therefore, the aim of this systematic review was to collect evidence on the accuracy of digital implant impression techniques, as well as to identify the main factors influencing the accuracy outcomes.
MATERIALS AND METHODS: Two reviewers searched electronic databases in November, 2016. Controlled vocabulary, free-text terms, and defined inclusion and exclusion criteria were used. Publications in English language evaluating the accuracy outcomes of digital implant impressions were identified. Pooled data were analysed qualitatively and pertinent data extracted.
RESULTS: In total, 16 studies fulfilled the inclusion criteria: one in vivo and 15 in vitro studies. The clinical study concluded that angular and distance errors were too large to be acceptable clinically. Less accurate findings were reported by several in vitro studies as well. However, all in vitro studies investigating the accuracy of newer generation IOS indicated equal or even better results compared with the conventional techniques. Data related to the influence of distance and angulation between implants, depth of placement, type of scanner, scanning strategy, characteristics of scanbody and reference scanner, operator experience, etc were analysed and summarised. Linear deviations (means) of IOS used in in vitro studies ranged from 6 to 337 µm. Recent studies indicated small angle deviations (0.07-0.3°) with digital impressions. Some studies reported that digital implant impression accuracy was influenced by implant angulation, distance between the implants, implant placement depth and operator experience.
CONCLUSIONS: According to the results of this systematic review and based on mainly in vitro studies, digital implant impressions offer a valid alternative to conventional impressions for single- and multi-unit implant-supported restorations. Further in vivo studies are needed to substantiate the use of currently available IOS, identify factors potentially affecting accuracy and define clinical indications for specific type of IOS. Data on Data on accuracy OF digital records, as well as accuracy of printed or milled models for implant-supported restorations, are of high relevance and are still lacking. Conflict-of-interest and funding statement: The authors state there is no conflict of interest.

Mesh:

Substances:

Year:  2017        PMID: 28944372

Source DB:  PubMed          Journal:  Eur J Oral Implantol        ISSN: 1756-2406            Impact factor:   3.123


  17 in total

Review 1.  Precision and practical usefulness of intraoral scanners in implant dentistry: A systematic literature review.

Authors:  Ignacio García-Gil; Jorge Cortés-Bretón-Brinkmann; Jaime Jiménez-García; Jesus Peláez-Rico; María-Jesús Suárez-García
Journal:  J Clin Exp Dent       Date:  2020-08-01

2.  In Vitro Comparison of Three Intraoral Scanners for Implant-Supported Dental Prostheses.

Authors:  Vitória Costa; António Sérgio Silva; Rosana Costa; Pedro Barreiros; Joana Mendes; José Manuel Mendes
Journal:  Dent J (Basel)       Date:  2022-06-15

3.  Accuracy of Digital Impression Taking with Intraoral Scanners and Fabrication of CAD/CAM Posts and Cores in a Fully Digital Workflow.

Authors:  Robert Leven; Alexander Schmidt; Roland Binder; Marian Kampschulte; Jonas Vogler; Bernd Wöstmann; Maximiliane Amelie Schlenz
Journal:  Materials (Basel)       Date:  2022-06-13       Impact factor: 3.748

4.  An Integrated Fully Digital Prosthetic Workflow for the Immediate Full-Arch Restoration of Edentulous Patients-A Case Report.

Authors:  Barbara Sobczak; Piotr Majewski
Journal:  Int J Environ Res Public Health       Date:  2022-03-31       Impact factor: 3.390

5.  Repeatability of Intraoral Scanners for Complete Arch Scan of Partially Edentulous Dentitions: An In Vitro Study.

Authors:  Jae-Hyun Lee; Je-Hyeon Yun; Jung-Suk Han; In-Sung Luke Yeo; Hyung-In Yoon
Journal:  J Clin Med       Date:  2019-08-08       Impact factor: 4.241

6.  Trueness of ten intraoral scanners in determining the positions of simulated implant scan bodies.

Authors:  Ryan Jin Young Kim; Goran I Benic; Ji-Man Park
Journal:  Sci Rep       Date:  2021-01-28       Impact factor: 4.379

7.  Accuracy of Digital and Conventional Full-Arch Impressions in Patients: An Update.

Authors:  Alexander Schmidt; Leona Klussmann; Bernd Wöstmann; Maximiliane Amelie Schlenz
Journal:  J Clin Med       Date:  2020-03-04       Impact factor: 4.241

8.  Accuracy of digital and conventional dental implant impressions for fixed partial dentures: A comparative clinical study.

Authors:  Agne Gedrimiene; Rimas Adaskevicius; Vygandas Rutkunas
Journal:  J Adv Prosthodont       Date:  2019-10-30       Impact factor: 1.904

9.  Dental implant location via surface scanner: a pilot study.

Authors:  Miao Zhou; Hui Zhou; Shu-Yi Li; Yuan-Ming Geng
Journal:  BMC Oral Health       Date:  2020-11-04       Impact factor: 2.757

10.  Accuracy of intraoral scanning in completely and partially edentulous maxillary and mandibular jaws: an in vitro analysis.

Authors:  Martin Schimmel; Norio Akino; Murali Srinivasan; Julia-Gabriela Wittneben; Burak Yilmaz; Samir Abou-Ayash
Journal:  Clin Oral Investig       Date:  2020-08-19       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.