Literature DB >> 28940974

Efficacy of constant load verification testing to confirm VO2 max attainment.

Todd A Astorino1, Jamie DeRevere1,2.   

Abstract

Although maximal oxygen uptake (VO2 max) has been measured for almost 100 years, it is unknown when 'true' VO2 max is attained. Primary (the VO2 plateau) and secondary criteria are used to confirm VO2 max incidence, but frequency of the VO2 plateau varies, and secondary criteria are relatively invalid. The verification test (VER) seems to elicit similar estimates of VO2 max versus the incremental value (INC), yet existing data are limited by small populations and use of inadequate criteria to confirm 'true' VO2 max. We investigated the efficacy of VER by analysing data from 109 participants who underwent INC followed by VER at 105% or 110% of peak power output (PPO). Differences in VO2 max between VER and INC were analysed, and intraclass correlation coefficient (ICC), standard error of the mean (SEM) and minimum difference (MD) were computed. Results showed that VO2 max was significantly higher (2%, P<0·05) in INC versus VER, VO2 max was highly related between protocols (ICC = 0·99) and SEM and MD were low. However, 11% of participants did not reveal 'true' VO2 max as the verification value was higher than INC by 3·0% - 3·3%. Fitness level altered the difference in VO2 max between INC and VER in study one, as lower fitness individuals showed a larger difference in VO2 max between protocols, although gender did not affect the difference in VO2 max between protocols. Our data show that VER does not verify 'true' VO2 max in all individuals, which may be related to their fitness level.
© 2017 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  constant load exercise; cycle ergometry; heart rate; intraclass correlation coefficient; maximal oxygen uptake

Mesh:

Year:  2017        PMID: 28940974     DOI: 10.1111/cpf.12474

Source DB:  PubMed          Journal:  Clin Physiol Funct Imaging        ISSN: 1475-0961            Impact factor:   2.273


  5 in total

1.  Supra-Versus Submaximal Cycle Ergometer Verification of VO2max in Males and Females.

Authors:  Brandon J Sawyer; Nicholas McMahon; Kirsten L Thornhill; Brett R Baughman; Jenny M Mahoney; Kai L Pattison; Kaitlin A Freeberg; Ryan T Botts
Journal:  Sports (Basel)       Date:  2020-12-12

2.  Verification-phase tests show low reliability and add little value in determining [Formula: see text]O2max in young trained adults.

Authors:  Jonathan Wagner; Max Niemeyer; Denis Infanger; Timo Hinrichs; Clement Guerra; Christopher Klenk; Karsten Königstein; Christian Cajochen; Arno Schmidt-Trucksäss; Raphael Knaier
Journal:  PLoS One       Date:  2021-01-11       Impact factor: 3.240

3.  Temporal Skin Temperature as an Indicator of Cardiorespiratory Fitness Assessed with Selected Methods.

Authors:  Agnieszka Danuta Jastrzębska; Rafal Hebisz; Paulina Hebisz
Journal:  Biology (Basel)       Date:  2022-06-21

Review 4.  The Oxygen Uptake Plateau-A Critical Review of the Frequently Misunderstood Phenomenon.

Authors:  Max Niemeyer; Raphael Knaier; Ralph Beneke
Journal:  Sports Med       Date:  2021-04-29       Impact factor: 11.136

5.  Verification of Maximal Oxygen Uptake in Active Military Personnel During Treadmill Running.

Authors:  Peter S Figueiredo; David P Looney; J Luke Pryor; Elizabeth M Doughty; Holly L McClung; Sai V Vangala; William R Santee; Beth A Beidleman; Adam W Potter
Journal:  J Strength Cond Res       Date:  2022-04-01       Impact factor: 3.775

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.