| Literature DB >> 28936256 |
Takaki Hiwasa1, Xiao-Meng Zhang1, Risa Kimura1, Mikiko Ohno2, Po-Min Chen2, Eiichiro Nishi2, Koh Ono2, Takeshi Kimura2, Ikuo Kamitsukasa3, Takeshi Wada4, Akiyo Aotsuka4, Seiichiro Mine5,6, Hirotaka Takizawa7, Koichi Kashiwado8, Minoru Takemoto9, Kazuki Kobayashi9, Harukiyo Kawamura9, Ryoichi Ishibashi9, Koutaro Yokote9, Rika Nakamura1,10, Go Tomiyoshi1,10, Natsuko Shinmen1,10, Hideyuki Kuroda10.
Abstract
Adiponectin secreted from the adipocytes plays pleiotropic, anti-atherosclerotic roles, such as enhancement of insulin secretion and an increase in energy expenditure. The measurement of levels of circulating adiponectin is useful to evaluate the progression of atherosclerosis-related diseases, such as coronary artery disease (CAD), cerebral infarction (CI) and diabetes mellitus (DM). We examined the serum antibody levels against recombinant adiponectin protein via the amplified luminescent proximity homogeneous assay-linked immunosorbent assay (AlphaLISA) method. The results revealed that the antibody levels were significantly higher in patients with CAD, CI and type 2 DM, than in healthy donors. Receiver operating curve analysis showed that the sensitivity was in a range of 41-48% for CAD, CI and DM. Thus, the serum anti-adiponectin antibody levels could be a common marker for atherosclerosis-related diseases.Entities:
Keywords: Antibody Biomarker; Atherosclerosis; Cardiovascular Disease; Cerebral Infarction; Diabetes Mellitus
Year: 2016 PMID: 28936256 PMCID: PMC5548317 DOI: 10.5772/63218
Source DB: PubMed Journal: J Circ Biomark ISSN: 1849-4544
Figure 1.Comparison of serum adiponectin antibodies (adiponectin-Ab) levels between the healthy donor (HD) subjects and patients with coronary artery disease (CAD). Serum antibody levels examined by AlphalLISA are shown by a box-whisker plot (a). The box plots display the 10th, 20th, 50th, 80th and 90th percentiles. P values as compared to the HD specimens are shown. Receiver operating curve (ROC) analysis was carried out for assessing the ability of adiponectin-Abs to detect CAD (b). Numbers in the curves indicate cut-off values of marker levels and those in parentheses indicate sensitivity (left) and specificity (right). P values of ROC analysis, areas under the curve (AUC) and a 95% confidence interval (CI) are also shown.
Comparison of serum anti-adiponectin antibody levels between the HD subjects and ACI, age-matched ACI, CAD, age-matched AMI and age-matched type 2 DM patients, examined by AlphaLISA. The table shows averages, SDs, cut-off values (average + 2SD), total sample numbers, the numbers of positive sera of which antibody levels were higher than the cut-off value and the positive rates (%) of the HD subjects; averages, SDs, total sample numbers, numbers of positive sera of which the antibody levels were higher than the cut-off value and the positive rates (%) of patients; and P values of the statistical comparison between the HD subjects and patients.
| CAD | AMI, age-matched | ACI | ACI, age-matched | DM, age-matched | ||
|---|---|---|---|---|---|---|
| HD | Average | 2,526 | 1,310 | 2,535 | 2,492 | 959 |
| SD | 640 | 455 | 368 | 383 | 673 | |
| Cut-off Value | 3,805 | 2,219 | 3,272 | 3,257 | 2,306 | |
| Total No. | 191 | 127 | 72 | 44 | 128 | |
| Positive No. | 13 | 6 | 2 | 2 | 6 | |
| Positive Rate (%) | 6.8% | 4.7% | 2.8% | 4.5% | 4.7% | |
| Patient | Average | 3,087 | 1,679 | 3,045 | 2,813 | 1,392 |
| SD | 1,368 | 550 | 1,078 | 896 | 1,076 | |
| Total No. | 378 | 128 | 286 | 54 | 128 | |
| Positive No. | 67 | 18 | 87 | 11 | 12 | |
| Positive Rate (%) | 17.7% | 14.1% | 30.4% | 20.4% | 9.4% | |
| P value | (Patient vs. HD) | 6.2E-11 | 1.6E-08 | 1.5E-10 | 2.4E-02 | 1.5E-04 |
Figure 2.Comparison of serum adiponectin-Ab levels between the HD subjects and patients with acute cerebral infarction (ACI). Serum antibody levels examined by AlphalLISA are shown by a box-whisker plot as described in the legend to Figure 1. The results were also evaluated by ROC analysis (b).
Figure 3.Comparison of serum adiponectin-Ab levels between the HD subjects and patients with type 2 diabetes mellitus (DM). Serum adiponectin-Ab levels examined by AlphalLISA are shown by a box-whisker plot as described in the legends of Figure 1 (a). The results were also evaluated by ROC analysis (b).