| Literature DB >> 28934833 |
Alireza Mohammadkarim1, Manijhe Mokhtari-Dizaji1, Ali Kazemian2, Hazhir Saberi3.
Abstract
PURPOSE: The aim of this study was to assess vascular changes and blood flow abnormalities in the common carotid arteries of patients with head and neck cancers after external radiotherapy, using color Doppler ultrasonography.Entities:
Keywords: Blood flow volume; Carotid artery, common; Radiotherapy; Ultrasonography
Year: 2017 PMID: 28934833 PMCID: PMC5769949 DOI: 10.14366/usg.17016
Source DB: PubMed Journal: Ultrasonography ISSN: 2288-5919
General characteristics of patients
| Characteristic | No. (%) |
|---|---|
| Age, mean土SD (yr) | 57±15 |
| Male sex | 15 (62.5) |
| Female sex | 9 (37.5) |
| Vascular disease | 4 (16.7) |
| High cholesterol | 4 (16.7) |
| Hypertension | 3 (12.5) |
| Tobacco use | 5 (20.8) |
| Chemotherapy | 9 (37.5) |
Cancer characteristics and radiation doses
| Patient characteristics | Patient | Dose (Gy) |
|---|---|---|
| Tumor site | ||
| Oral cavity | 9 (25.0) | 57±7 |
| Larynx | 8 (20.8) | 70±0 |
| Parotid | 2 (8.3) | 50±14 |
| Lymphoma | 2 (8.3) | 40±0 |
| Oropharyngeal region | 1 (4.2) | 70±0 |
| Glomus | 1 (4.2) | 50±0 |
| Thyroid | 1 (4.2) | 20±0 |
| Mean dose of all subjects | 59±11 |
Values are presented as number (%) or mean±SD.
Fig. 1.Color Doppler ultrasonography of the common carotid artery with a blood velocity spectrum.
The diameter of the common carotid artery was determined for each subject. The peak systolic velocity (Vp), end diastolic velocity (Ve), and mean velocity (VM) of the common carotid artery were extracted from the color Doppler examination.
Fig. 2.Instantaneous changes in the internal diameter of the common carotid artery throughout three cardiac cycles, evaluated using the computational method.
The peak systolic diameter (dp), end diastolic diameter (de), and mean value diameter (dM) of each lumen were determined from sequential ultrasonic images throughout three cardiac cycles.
Lumen diameter and blood flow velocity parameters of the common carotid arteries before and after external radiotherapy
| Parameter | Pre-irradiation | Post-irradiation | P-value |
|---|---|---|---|
| Peak systolic velocity (cm/sec) | 47.80±9.72 | 55.26±13.24 | 0.12 |
| End diastolic velocity (cm/sec) | 12.83±2.68 | 11.09±3.64 | 0.025 |
| Mean velocity (cm/sec) | 22.88±4.57 | 23.3±5.18 | 0.035 |
| Pulsatility index | 1.58±0.37 | 1.78±0.43 | 0.027 |
| Resistive index | 0.73±0.06 | 0.79±0.05 | <0.001 |
| Systolic to diastolic velocity ratio | 4.04±0.98 | 4.88±1.31 | 0.010 |
| dmeas (mm) | 6.12±0.54 | 5.26±0.52 | <0.001 |
| dp (mm) | 6.42±0.67 | 5.63±0.67 | <0.001 |
| de (mm) | 5.56±0.58 | 4.92±0.55 | <0.001 |
| dM (mm) | 6.05±0.64 | 5.29±0.60 | <0.001 |
Lumen diameter parameters were obtained by two methods: a clinical investigation (dmeas) and the automated diameter that was calculated using the image processing procedure (dp, de, dM).
Blood VF before and after external radiotherapy obtained using two methods: clinical investigations (VFmeas) and calculated using the image processing (VFp, VFe, and VFM)
| Ultrasonic parameter | Pre-irradiation | Post-irradiation | P-value |
|---|---|---|---|
| Blood VFmeas (mL/min) | 395.20±36.39 | 313.79±101.10 | <0.001 |
| Blood VFp (mL/min) | 926.18±218.42 | 778.16±266.20 | 0.003 |
| Blood VFe (mL/min) | 187.62±52.61 | 125.63±46.11 | <0.001 |
| Blood VFM (mL/min) | 387.94±105.80 | 306.39±85.48 | <0.001 |
VF, volume flow.