Literature DB >> 16484412

Blood-flow volume quantification in internal carotid and vertebral arteries: comparison of 3 different ultrasound techniques with phase-contrast MR imaging.

S O Oktar1, C Yücel, D Karaosmanoglu, K Akkan, H Ozdemir, N Tokgoz, T Tali.   

Abstract

BACKGROUND AND
PURPOSE: Optimal estimation of cerebral blood-flow volume (BFV) may be an important indicator for better evaluation of the patients with cerebrovascular disorders. In this study, we compared the BFV values at bilateral internal carotid and vertebral arteries of healthy volunteers obtained with color Doppler, power Doppler, and B-flow ultrasound (US) studies and tried to determine which examination is more correlated with MR phase-contrast quantification.
METHODS: BFVs of the internal carotid and vertebral arteries of 40 healthy volunteers (19 men and 21 women; age range, 20-47 years) were measured by using color Doppler, power Doppler, B-flow US and MR phase-contrast imaging. The flow measurements obtained with the sonographic techniques were compared with MR phase contrast, which is accepted as the most reliable method for the estimation of cerebral BFV.
RESULTS: Quantification with power Doppler imaging showed the highest values among sonography techniques, followed by color Doppler imaging, B-flow imaging (BFI), and MR phase-contrast flow quantification. There was a statistically significant difference between the flow-volume values obtained with these 4 different techniques (P < .05). BFI yielded the closest values (internal carotid arteries, 238.84 mL/min; vertebral arteries, 51.16 mL/min) to MR phase-contrast flow quantification study with higher correlation rates.
CONCLUSION: Flow volumes obtained with BFI showed the highest correlation with MR phase-contrast imaging among 3 different sonography techniques. B-flow sonography may be a very effective and cost-efficient alternative for MR phase-contrast studies for the calculation of cerebral BFV.

Entities:  

Mesh:

Year:  2006        PMID: 16484412      PMCID: PMC8148782     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  25 in total

1.  The application of color power angiography to the longitudinal quantification of blood flow volume in the fetal middle cerebral arteries, ascending aorta, descending aorta, and renal arteries during gestation.

Authors:  J C Konje; K Abrams; S C Bell; R C de Chazal; D J Taylor
Journal:  Am J Obstet Gynecol       Date:  2000-02       Impact factor: 8.661

2.  [B-flow--a new method for detecting blood flow].

Authors:  H P Weskott
Journal:  Ultraschall Med       Date:  2000-04       Impact factor: 6.548

3.  Improved phase-contrast flow quantification by three-dimensional vessel localization.

Authors:  M Zhao; F T Charbel; N Alperin; F Loth; M E Clark
Journal:  Magn Reson Imaging       Date:  2000-07       Impact factor: 2.546

4.  Assessment of cerebral blood flow by means of blood-flow-volume measurement in the internal carotid artery: comparative study with a 133xenon clearance technique.

Authors:  J F Soustiel; T C Glenn; P Vespa; B Rinsky; C Hanuscin; N A Martin
Journal:  Stroke       Date:  2003-07-03       Impact factor: 7.914

5.  Flow quantification using fast cine phase-contrast MR imaging, conventional cine phase-contrast MR imaging, and Doppler sonography: in vitro and in vivo validation.

Authors:  V S Lee; C E Spritzer; B A Carroll; L G Pool; M A Bernstein; S K Heinle; J R MacFall
Journal:  AJR Am J Roentgenol       Date:  1997-10       Impact factor: 3.959

6.  Reference values for vertebral artery flow volume by duplex sonography in young and elderly adults.

Authors:  E Seidel; B M Eicke; B Tettenborn; F Krummenauer
Journal:  Stroke       Date:  1999-12       Impact factor: 7.914

7.  Accuracy and precision of time-averaged flow as measured by nontriggered 2D phase-contrast MR angiography, a phantom evaluation.

Authors:  C J Bakker; M Kouwenhoven; M J Hartkamp; R M Hoogeveen; W P Mali
Journal:  Magn Reson Imaging       Date:  1995       Impact factor: 2.546

8.  Combined use of color duplex ultrasonography and B-flow imaging for evaluation of patients with carotid artery stenosis.

Authors:  Muharrem Tola; Mehmet Yurdakul; Turhan Cumhur
Journal:  AJNR Am J Neuroradiol       Date:  2004 Nov-Dec       Impact factor: 3.825

9.  Clinical cerebrovascular applications of arterial ultrasound volume flow rate estimates.

Authors:  V A Knappertz; C H Tegeler; L G Myers
Journal:  J Neuroimaging       Date:  1996-01       Impact factor: 2.486

10.  Cerebrovascular disease assessed by color-flow and power Doppler ultrasonography. Comparison with digital subtraction angiography in internal carotid artery stenosis.

Authors:  B Griewing; C Morgenstern; F Driesner; G Kallwellis; M L Walker; C Kessler
Journal:  Stroke       Date:  1996-01       Impact factor: 7.914

View more
  39 in total

1.  ACCF/ACR/AHA/NASCI/SCMR 2010 expert consensus document on cardiovascular magnetic resonance: a report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents.

Authors:  W Gregory Hundley; David A Bluemke; J Paul Finn; Scott D Flamm; Mark A Fogel; Matthias G Friedrich; Vincent B Ho; Michael Jerosch-Herold; Christopher M Kramer; Warren J Manning; Manesh Patel; Gerald M Pohost; Arthur E Stillman; Richard D White; Pamela K Woodard
Journal:  Circulation       Date:  2010-05-17       Impact factor: 29.690

Review 2.  ACCF/ACR/AHA/NASCI/SCMR 2010 expert consensus document on cardiovascular magnetic resonance: a report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents.

Authors:  W Gregory Hundley; David A Bluemke; J Paul Finn; Scott D Flamm; Mark A Fogel; Matthias G Friedrich; Vincent B Ho; Michael Jerosch-Herold; Christopher M Kramer; Warren J Manning; Manesh Patel; Gerald M Pohost; Arthur E Stillman; Richard D White; Pamela K Woodard
Journal:  J Am Coll Cardiol       Date:  2010-06-08       Impact factor: 24.094

3.  In vivo assessment and visualization of intracranial arterial hemodynamics with flow-sensitized 4D MR imaging at 3T.

Authors:  S Wetzel; S Meckel; A Frydrychowicz; L Bonati; E-W Radue; K Scheffler; J Hennig; M Markl
Journal:  AJNR Am J Neuroradiol       Date:  2007-03       Impact factor: 3.825

4.  Haemodynamic alterations in cerebral blood vessels after carotid artery revascularisation: quantitative analysis using 2D phase-contrast MRI.

Authors:  Sung Won Youn; Ho Kyun Kim; Young Rok Do; Jin Kook Do; Oh Choon Kwon; Nahee Lee; Hui Joong Lee; Jongmin Lee
Journal:  Eur Radiol       Date:  2013-06-04       Impact factor: 5.315

5.  Dampening of blood-flow pulsatility along the carotid siphon: does form follow function?

Authors:  T Schubert; F Santini; A F Stalder; J Bock; S Meckel; L Bonati; M Markl; S Wetzel
Journal:  AJNR Am J Neuroradiol       Date:  2011-04-07       Impact factor: 3.825

6.  Optimal 4DFlow MR sequence parameters for the assessment of internal carotid artery stenosis: a simulation study.

Authors:  Myriam Edjlali; Catherine Oppenheim; Joseph Benzakoun; Pauline Roca; David Calvet; Olivier Naggara; Stéphanie Lion; Marie-Pierre Gobin-Metteil; Sylvain Charron; Victoria Cavero; Jean-François Meder
Journal:  Neuroradiology       Date:  2019-06-13       Impact factor: 2.804

7.  REPLY.

Authors:  R Doddasomayajula; C Putman; J R Cebral
Journal:  AJNR Am J Neuroradiol       Date:  2017-05-18       Impact factor: 3.825

8.  Quantitative Measurements of Cerebral Circulation in Spontaneously Regressing Traumatic Carotid-Cavernous Sinus Fistula with Velocity-Encoded Magnetic Resonance Imaging.

Authors:  Ho Kyun Kim; Sung Won Youn; Jongmin Lee
Journal:  Clin Neuroradiol       Date:  2014-04-10       Impact factor: 3.649

9.  Time-delayed contrast-enhanced MRI improves detection of brain metastases: a prospective validation of diagnostic yield.

Authors:  Or Cohen-Inbar; Zhiyuan Xu; Blair Dodson; Tanvir Rizvi; Christopher R Durst; Sugoto Mukherjee; Jason P Sheehan
Journal:  J Neurooncol       Date:  2016-08-27       Impact factor: 4.130

10.  In vivo visualization and analysis of 3-D hemodynamics in cerebral aneurysms with flow-sensitized 4-D MR imaging at 3 T.

Authors:  Stephan Meckel; Aurelien F Stalder; Francesco Santini; Ernst-Wilhelm Radü; Daniel A Rüfenacht; Michael Markl; Stephan G Wetzel
Journal:  Neuroradiology       Date:  2008-03-19       Impact factor: 2.804

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.