Literature DB >> 28929022

Development and evaluation of rapid novel isothermal amplification assays for important veterinary pathogens: Chlamydia psittaci and Chlamydia pecorum.

Martina Jelocnik1, Md Mominul Islam1, Danielle Madden1, Cheryl Jenkins2, James Branley3, Scott Carver4, Adam Polkinghorne1.   

Abstract

BACKGROUND: Chlamydia psittaci and Chlamydia pecorum are important veterinary pathogens, with the former also being responsible for zoonoses, and the latter adversely affecting koala populations in Australia and livestock globally. The rapid detection of these organisms is still challenging, particularly at the point-of-care (POC). In the present study, we developed and evaluated rapid, sensitive and robust C. psittaci-specific and C. pecorum-specific Loop Mediated Isothermal Amplification (LAMP) assays for detection of these pathogens. METHODS AND MATERIALS: The LAMP assays, performed in a Genie III real-time fluorometer, targeted a 263 bp region of the C. psittaci-specific Cps_0607 gene or a 209 bp region of a C. pecorum-specific conserved gene CpecG_0573, and were evaluated using a range of samples previously screened using species-specific quantitative PCRs (qPCRs). Species-specificity for C. psittaci and C. pecorum LAMP targets was tested against DNA samples from related chlamydial species and a range of other bacteria. In order to evaluate pathogen detection in clinical samples, C. psittaci LAMP was evaluated using a total of 26 DNA extracts from clinical samples from equine and avian hosts, while for C. pecorum LAMP, we tested a total of 63 DNA extracts from clinical samples from koala, sheep and cattle hosts. A subset of 36 C. pecorum samples was also tested in a thermal cycler (instead of a real-time fluorometer) using newly developed LAMP and results were determined as an end point detection. We also evaluated rapid swab processing (without DNA extraction) to assess the robustness of these assays.
RESULTS: Both LAMP assays were demonstrated to species-specific, highly reproducible and to be able to detect as little as 10 genome copy number/reaction, with a mean amplification time of 14 and 24 min for C. psittaci and C. pecorum, respectively. When testing clinical samples, the overall congruence between the newly developed LAMP assays and qPCR was 92.3% for C. psittaci (91.7% sensitivity and 92.9% specificity); and 84.1% for C. pecorum (90.6% sensitivity and 77.4% specificity). For a subset of 36 C. pecorum samples tested in a thermal cycler using newly developed LAMP, we observed 34/36 (94.4%) samples result being congruent between LAMP performed in fluorometer and in thermal cycler. Rapid swab processing method evaluated in this study also allows for chlamydial DNA detection using LAMP. DISCUSSION: In this study, we describe the development of novel, rapid and robust C. psittaci-specific and C. pecorum-specific LAMP assays that are able to detect these bacteria in clinical samples in either the laboratory or POC settings. With further development and a focus on the preparation of these assays at the POC, it is anticipated that both tests may fill an important niche in the repertoire of ancillary diagnostic tools available to clinicians.

Entities:  

Keywords:  Chlamydia pecorum; Chlamydia psittaci; Clinical samples; Diagnostics; LAMP; Rapid tests

Year:  2017        PMID: 28929022      PMCID: PMC5592900          DOI: 10.7717/peerj.3799

Source DB:  PubMed          Journal:  PeerJ        ISSN: 2167-8359            Impact factor:   2.984


Introduction

The obligatory intracellular bacteria, Chlamydia psittaci and Chlamydia pecorum, are globally widespread veterinary pathogens that cause disease in an astonishing range of hosts. C. psittaci, the causative agent of psittacosis or wasting bird disease, is regarded as a major economically relevant poultry and pet bird pathogen (Knittler & Sachse, 2015; Szymanska-Czerwinska & Niemczuk, 2016). Globally, C. psittaci infections are also sporadically reported in other animal species such as pigs, cattle, sheep and horses, resulting in asymptomatic shedding, acute respiratory disease and, in the case of horses, reproductive loss (Reinhold, Sachse & Kaltenboeck, 2011; Knittler & Sachse, 2015; Jelocnik et al., 2017). Importantly, this pathogen continues to pose risks to public health through zoonotic transmission events that may lead to severe pneumonia (Gaede et al., 2008; Laroucau et al., 2015; Branley et al., 2016). This zoonotic risk is typically associated with direct contact with C. psittaci infected birds, although indirect contact through exposure to environmental contamination has been suggested (Branley et al., 2014; Branley et al., 2016). C. pecorum is perhaps best known as the major pathogen of the iconic Australian native species, the koala. These infections are most commonly asymptomatic but can also result in serious inflammatory ocular and/or urogenital disease, affecting almost all Australia’s mainland koala populations (Polkinghorne, Hanger & Timms, 2013; Gonzalez-Astudillo et al., 2017). C. pecorum is also an important livestock pathogen causing a range of debilitating diseases such as sporadic bovine encephalomyelitis, polyarthritis, pneumonia and conjunctivitis, with faecal shedding as a constant feature of these infections (Lenzko et al., 2011; Reinhold, Sachse & Kaltenboeck, 2011; Walker et al., 2015). In livestock, chlamydial pathogens such as C. pecorum and C. psittaci may be found as co-infections, raising the possibility of a synergistic pathogenic effect (Lenzko et al., 2011; Reinhold, Sachse & Kaltenboeck, 2011; Knittler & Sachse, 2015). The reports of chlamydial infections in novel hosts and their recognised pathogenic potential (Jelocnik et al., 2015b; Burnard & Polkinghorne, 2016; Taylor-Brown & Polkinghorne, 2017), further highlight the need for faster detection and molecular discrimination of infecting strains. Whilst significant progress has been made in understanding the molecular epidemiology of C. psittaci and C. pecorum infections (Jelocnik et al., 2015a; Branley et al., 2016), the diagnosis and detection of these pathogens is still difficult, laborious and costly, challenging efforts to manage and treat infected hosts. A variety of traditional (cell culture, antigen detection, and serology) and molecular (conventional and real-time quantitative PCR (qPCR)) diagnostic options are used to detect chlamydial infections and diagnose chlamydiosis (Sachse et al., 2009). For both C. psittaci and C. pecorum, nucleic acid amplification tests (NAATs) are presently considered the diagnostic “gold standard” due to their specificity and sensitivity, however the use of these assays is mainly restricted to research and/or diagnostic laboratories. In the absence of standardised gene target(s) for these organisms, numerous single or nested species-specific qPCR assays have been proposed and/or are used for C. psittaci (Madico et al., 2000; Geens et al., 2005; Menard et al., 2006; Branley et al., 2008) and C. pecorum (Marsh et al., 2011; Higgins et al., 2012; Wan et al., 2011; Walker et al., 2016) diagnosis. The development and use of low-cost molecular diagnostic tools performed at the point-of-care (POC) which fulfil the World Health Organization “ASSURED” criteria of affordable, sensitive, specific, user-friendly, rapid, equipment-free, and deliverable to those in need to be tested, are on the exponential rise (Maffert et al., 2017). While POC testing is not necessarily required when considering most chlamydial infections of veterinary concern, the ability to provide a rapid detection of infections becomes of increasing significance when veterinarians and other animal workers may be at risk of being exposed to C. psittaci infections in field or farm settings. POC testing is also particularly relevant for Chlamydia screening in wild animals where laboratory testing is not accessible either due to logistics associated with field sampling or that services are not routinely available for testing of samples from wildlife. The latter problem is particularly acute for diagnosing infections in koalas, with the recent decision to stop the production of a commercially viable solid-phase ELISA leaving wildlife hospitals unable to diagnose and successfully treat asymptomatic C. pecorum infections (Hanger et al., 2013). While there are many options for molecular POC diagnostics, Loop Mediated Isothermal Amplification (LAMP) assays developed for use in pathogen diagnostics are popular as they offer significant advantages over PCR and/or serology testing (Maffert et al., 2017). Rapid, simple, highly specific, easy to interpret, and carried out at a constant temperature, LAMP assays can provide a diagnosis in 30 min, in either laboratory or field setting (Mansour et al., 2015; Notomi et al., 2015). Rapid isothermal LAMP assays that could be performed at the POC targeting human C. pneumoniae (Kawai et al., 2009) and C. trachomatis (Jevtusevskaja et al., 2016; Choopara et al., 2017) infections have been proposed for use in chlamydial diagnostics. Development of a C. pecorum LAMP, in particular, would meet immediate demand for koala C. pecorum infections diagnostics, providing an alternative solution for the current laboratory diagnostics. A recent outbreak of psittacosis in veterinary staff and students in contact with a C. psittaci-infected and sick neonatal foal (Chan et al., 2017; Jelocnik et al., 2017), further demonstrates the need for POC assays such as LAMP to rapidly diagnose C. psittaci. In the present study, we describe the development and evaluation of rapid and robust C. psittaci-specific and C. pecorum-specific LAMP assays for detection of these organisms in either laboratory or POC settings.

Materials and Methods

Bacterial cultures and clinical samples used in this study

C. psittaci LAMP assay was evaluated using: (1) 12 DNA samples extracted from previously characterised C. psittaci isolates (10 human, two parrot and one equine) (Table S1); (2) DNA extracted from 21 placental, foetal, nasal, lung and rectal swabs, and 1 each placental and foetal tissue sample taken from 20 equine hosts; and (3) three pigeon liver DNA extracts (Table S2). All samples were collected and submitted as part of routine diagnostic testing by field or district veterinarians to the State Veterinary Diagnostic Laboratory (SVDL), Elizabeth Macarthur Agricultural Institute (EMAI), Menangle, NSW, Australia, and as such do not require special animal ethics approval. DNA extracts from these samples were kindly provided by Dr. Cheryl Jenkins, and Dr. James Branley. The use of these swabs was considered by the University of The Sunshine Coast (USC) Animal Ethics Committee and the need for further ethics consideration was waived under exemption AN/E/17/19. C. pecorum LAMP was evaluated using a: (1) 18 DNA samples extracted from previously characterised koala (n = 7), sheep (n = 4), cattle (n = 4) and pig C. pecorum (n = 3) cultures (Table S1); (2) 16 sheep and 13 cattle ocular, rectal, and tissue swab DNA samples; and (3) 34 ocular and urogenital (UGT) koala swab DNA samples (Table S3), all available in our collection. The use of these swabs, also collected by qualified veterinarians as a part of routine diagnostic testing, was considered and approved for exemption by the University of The Sunshine Coast (USC) Animal Ethics Committee (AN/E/14/01 and AN/E/14/31). We also evaluated the specificity of the assays against DNA samples extracted from previously characterised (i) chlamydial isolates (koala C. pneumoniae LPColN, C. abortus S26/3, C. suis S45, C. trachomatis serovar D, C. murridarum Nigg, C. caviae GPIC) and uncultured Chlamydiales (Fritschea spp.); (ii) Gram negative Escherichia coli and Prevotella bivia; Gram positive Fusobacterium nucleatum, Staphylococcus epidermidis, S. aureus, Streptococcus spp., and Enterococcus faecalis; and (iii) commercially available human gDNA (Promega, Alexandria, NSW 2015), all available in our laboratory (Table S1). In order to evaluate rapid swab processing, 18 ocular, cloacal and UGT (14 dry and four RNA-Later) clinical swabs taken from 14 koalas with presumptive chlamydiosis were used for testing without DNA extraction. Briefly, RNA-Later and dry swabs with added 500 µL TE buffer were vortexed vigorously for 5 min. 300 µL aliquots were then heated to 98 °C for 15 min to lyse DNA, following LAMP testing. The use of these swabs, collected as a part of routine diagnostic testing, is also under Animal Ethics approval exemption (AN/E/14/01). An aliquot of 50 µL of the swab suspension was used for LAMP and qPCR assays, while from the remaining volume of the swab suspension was used for DNA extraction, in order to compare swab suspension and its paired extracted DNA as a template in the assays.

LAMP assays design

For the C. psittaci-specific LAMP gene target, we targeted a previously described conserved single-copy C. psittaci-specific CDS, encoding for hypothetical protein and denoted Cpsit_0607 in the representative C. psittaci 6BC strain (Genbank accession number NC_015470.1) (Voigt, Schöfl & Saluz, 2012). This gene was also previously proposed as a target for molecular diagnosis of C. psittaci infections (Opota et al., 2015). The C. pecorum-specific candidate LAMP gene target, encoding for a single-copy conserved hypothetical protein and denoted CpecG_0573 in the C. pecorum MC/Marsbar koala type strain (GenBank accession number NZ_CM002310.1), was selected based on a comparative genomics analysis of published koala and livestock C. pecorum genomes (Jelocnik et al., 2015a). For the purposes of this study, we will refer to it as Cpec_HP. Both candidate gene sequences were aligned to the corresponding allele from other publicly available C. psittaci or C. pecorum strains using Clustal X (as implemented in Geneious 9 (Kearse et al., 2012)), and analysed in blastn against the nucleotide collection nr/nt database to assess intra-species sequence identity, and inter-species specificity. For C. ps_0607 alignment, besides 6BC, we used the gene alleles from strains 84/55 (CP003790.1), 02DC15 (CP002806.1), 01DC11 (CP002805.1), WC (CP003796.1), 01DC12 (HF545614.1), NJ1 (CP003798.1), CR009 (LZRX01000000), Ho Re upper (LZRE01000000) and PoAn (LZRG01000000). For C. pec _HP alignment, besides MC/Marsbar, we used the gene alleles from E58 (CP002608.1), P787 (CP004035.1), W73 (CP004034.1), IPA (NZ_CM002311.1), NSW/Bov/SBE (NZ_JWHE00000000.1), L71 (LFRL01000000), L17 (LFRK01000001), L1 (LFRH00000000), DBDeUG (NZ_CM002308.1), SA/K2/UGT (SRR1693792), Nar/S22/Rec (SRR1693794) and Mer/Ovi1/Jnt (SRR1693791). Species-specific LAMP primers were designed using the target sequences with the open-source Primer Explorer v5 software (Eiken Chemical Co., Tokyo, Japan) and licensed LAMP Designer 1.15 software (Premier Biosoft, Palo Alto, CA, USA). For both C. pecorum and C. psittaci, Primer Explorer v5 yielded five sets of four LAMP primers including two outer (forward F3 and backward B3) primers and two inner (forward inner FIP and backward inner BIP) primers targeting different regions of the target gene, while LAMP Designer yielded single best set of six LAMP primers including two outer primers (forward F3 and backward B3), two inner primers (forward inner FIP and backward inner BIP) and two loop primers (forward loop LF and backwards loop LB). All primers (as single or paired) were tested in silico, including analysing primer sequences in blast for species specificity and OligoAnalyser 3.1 (available from http://sg.idtdna.com/calc/analyzer) for primer dimerization, hairpins and melting temperatures. After in silico and in LAMP reaction testing, a set of four primers designed by PrimerExplorer v5 and targeting a 209 bp region of the C. pec_HP gene (spanning from position 22 to 230) was selected for C. pecorum LAMP assays performed in this study. Additional loop primers (LF/LB) were also designed to accelerate amplification time and increase sensitivity. For C. psittaci, a set of six primers designed with LAMP Designer and targeting a 263 bp region of the C. ps_0607 gene (spanning from position 286 to 548) was selected for LAMP assays performed in this study. The specificity of primer sequences was assessed in silico using discontiquousBLAST analyses. Amplicons generated by conventional PCR using outer F3 and B3 primers for both C. psittaci and C. pecorum were gel excised, purified using Roche High Pure purification kit, and sent to Australian Genome Research Facility (AGRF) for Sanger sequencing for sequence identity confirmation.

LAMP assay optimisation

Both C. psittaci and C. pecorum LAMP assays were carried out in a 25 µL reaction volume. The reaction mixture consisted of 15 µL Isothermal Master Mix ISO001 (Optigene, Horsham, UK), 5 µL six primers mix (at 0.2 µM F3 and B3, 0.8 µM FIP and BIP, and 0.4 µM LF and LB) and 5 µL template, following LAMP assay run at 65 °C in the Genie III real-time fluorometer (Optigene, Horsham, UK), as per manufacturer instructions. Following determination of the most optimal conditions (fastest amplification time, fluorescence and annealing temperature), C. psittaci LAMP assays were run at 65 °C for 30 min followed by annealing step of 98–80 °C at a rate of 0.05 °C/s, while C. pecorum LAMP assays were run using the same temperature and annealing conditions, however for 45 min. A negative control (LAMP mix only) was included in each run. Both C. psittaci and C. pecorum LAMP assays were performed on a thermal cycle heating block at 65 °C for 30 min, following detection of amplicons by electrophoresis on a 1.5% ethidium bromide agarose gel and visualisation under UV. In addition, several C. pecorum LAMP assays were conducted using the four primer set, two outer (F3 and B3) and two inner (FIP and BIP) primers, on a heating block at 65 °C for 45 min. After the assay optimisation, LAMP testing was evaluated using previously tested clinical samples, previously characterised isolates and untested new samples. C. pecorum-presumptive samples were simultaneously tested using our in-house C. pecorum–specific qPCR assay (Marsh et al., 2011), while C. psittaci-presumptive samples were tested using a pan-Chlamydiales qPCR assay with primers 16SIGF and 16SIGR targeting the 298 bp 16S rRNA fragment (Everett, Bush & Andersen, 1999). Amplicon sequencing was used for the latter assay to confirm species identity. The qPCR assays were carried out in a 20 µL total volume, consisting of 10 µL SYBR™ Green PCR Master Mix (Life Technologies Australia Pty Ltd., Scoresby, Victoria, Australia), 1 µL of each 10 µM forward and reverse primer, 3 µL miliqH2O, and 5 µL DNA template. The qPCR assays were run for 35 cycles (Ct), and in each qPCR assay a positive (cultured C. pecorum and/or C. psittaci DNA) and negative (miliqH2O) controls were included. Based on the qPCR standard curve and the number of running cycles, samples amplifying at >30 Ct (and/or equivalent detected genome copy number) were considered negative. The 23 C. psittaci-presumptive equine samples were also tested with a C. psittaci-specific qPCR assay targeting the 16S rRNA gene/16S-23S rRNA spacer gene (Madico et al., 2000) at the State Veterinary Diagnostic Laboratory (SVDL), Elizabeth Macarthur Agricultural Institute (EMAI), Menangle, NSW, Australia. Samples amplifying at >39 Ct were considered negative. LAMP testing was performed in a blind fashion, by two different operators, unaware of qPCR results.

Statistical analyses

For each assay, we compared the performance of two tests evaluated in the same population by calculating Kappa and overall agreement, as well as estimated sensitivity and specificity (with specified Clopper–Pearson (exact) confidence limits) of LAMP compared to the known reference (gold standard) qPCR test using EpiTools online (Sergeant, 2017). It is suggested the Kappa value be interpreted as follows: values ≤0 as indicating no agreement and 0.01–0.20 as none to slight, 0.21–0.40 as fair, 0.41–0.60 as moderate, 0.61–0.80 as substantial, and 0.81–1.00 as almost perfect agreement.

Results and Discussion

With the emergence of new spill-over threats posed by C. psittaci (Laroucau et al., 2015; Jelocnik et al., 2017), there is an increasing need for rapid diagnostic tools for this pathogen, particularly for those that may have practical application in the field or clinical setting. There are specific needs for C. pecorum POC tests as well in both the veterinary care and treatment of infected domesticated and native animals, particularly in settings where veterinary diagnostic testing is logistically challenging. In the present study, to the best of our knowledge, we describe the first development of novel, rapid and robust C. psittaci-specific and C. pecorum-specific LAMP assays that are able to detect these bacteria in clinical samples in either the laboratory or POC settings.

C. psittaci and C. pecorum LAMP development

A C. psittaci-specific gene (C.ps_0607) was previously characterised as a conserved gene sequence present only in C. psittaci genomes, and absent from all other related chlamydial species (Voigt, Schöfl & Saluz, 2012). BLAST analyses and alignment of the C.ps_0607 gene sequences, including those from recently described human, bird and equine Australian isolates, confirmed species specificity and sequence conservation. Between 0 and 13 single nucleotide polymorphisms (SNPs) were observed amongst strains (100–95.1% sequence identity) based on a 263 bp alignment of C.ps_0607 gene sequences, including that from the most distant C. psittaci NJ1 taxon (Fig. S1A). Similarly, the C. pecorum HP gene (denoted CpecG_0573 locus in Marsbar strain) was determined as a highly conserved species-specific sequence following BLAST analysis against publicly available sequences. Using an alignment of HP gene sequences from 14 publicly available C. pecorum genomes, there were only two SNPs in the 209 bp region to be targeted by LAMP (Fig. S1B). Although multiple LAMP primer sets were predicted, LAMP primer sets denoted in Fig. 1 were chosen for further assay development. For C. psittaci assays, a set designed using LAMP Explorer was utilised while, for C. pecorum, we used a set designed with PrimerExplorer (Table 1). After initial testing, some of the predicted primer sets were discarded due to (i) potential cross-amplification associated with a lack of specificity of the target primer; (ii) not achieving an amplification signal in the fluorometer; and (iii) amplifying non-specific targets, including positive amplification in negative controls (data not shown). While we achieved initial amplification of a C. psittaci single copy dilution in a 30 min assay using the designed LAMP primer set, initial reaction times for a C. pecorum single copy amplification averaged 50 min. In order to accelerate amplification times for C. pecorum, we additionally designed a pair of Loop primers for the C. pecorum set which decreased the amplification of a single copy to 30 min.
Figure 1

LAMP primer sequences and positions in the target gene regions.

(A) C. psittaci LAMP primer set; and (B) C. pecorum LAMP primer set. Outer F3 and B3 primers are indicated in green, inner FIP and BIP in blue, and loop LF and BL in pink colour.

Table 1

LAMP primers set used in this study.

NameSequence 5′–3′PositionLength
C. psittaciLAMP primers
F3AGAACCGGATTAGGAGTCTT28620
B3GCTGCTAAAGCGAGTATTGA54820
FIP(F1c + F2)TCCGCAGTTTGTTCCATCACCCAA GGGTTATTCGACAACTACT43
BIP(B1c + B2)ACTATGGATCGGCCACACATGGG TATGTTGCTTTGAATGGG41
LoopFTTCAGGTAATCACGCACTTGA35021
LoopBTTCCCCACACTATTAAACAGCA43122
F2CAAGGGTTATTCGACAACTACT30722
F1cTCCGCAGTTTGTTCCATCACC38721
B2GGTATGTTGCTTTGAATGGG47220
B1cACTATGGATCGGCCACACATG41021
C. pecorumLAMP primers
F3ATCGGGACCTTCTCATCG2218
B3GCTGTTGTAAGGAAGACTCC23020
FIP(F1c + F2)GACTAACAGTATAAGCAGTGCTG TTAGTCTGCTGTCCAACTACA44
BIP(B1c + B2)TTATCTCTCGTTGCAATGATAGGAG CCAACAGGATCAAACCAACTT46
LoopFCTGAATTCGTTGAC9314
LoopBTACTGTCTTCACC16512
F2AGTCTGCTGTCCAACTACA4719
F1cGACTAACAGTATAAGCAGTGCTGTT12925
B2CAACAGGATCAAACCAACTT21020
B1cTTATCTCTCGTTGCAATGATAGGAGC13026

LAMP primer sequences and positions in the target gene regions.

(A) C. psittaci LAMP primer set; and (B) C. pecorum LAMP primer set. Outer F3 and B3 primers are indicated in green, inner FIP and BIP in blue, and loop LF and BL in pink colour. Species-specificity for C. psittaci and C. pecorum LAMP targets was tested in the developed LAMP assays using DNA extracts from 12 C. psittaci and 18 C. pecorum cultured isolates, DNA extracts from other chlamydial species and a range of DNA extracts from other bacteria. Positive amplification as assessed by the presence of an observable amplification curve characterised by a specific melt was observed only for the target species in their respective assays (Table S1). No amplification curves were observed for any of the non-targeted chlamydial species or other bacteria included in our specificity assays (Table S1). The C. pecorum and C. psittaci LAMP assays did not amplify either the related chlamydial species or other bacteria included in our specificity assays. In this study, in contrast, a previously described “C. pecorum-specific” qPCR assay (Marsh et al., 2011; Wan et al., 2011) showed positive amplification and melt for C. psittaci and C. pneumoniae DNA samples. The choice to use the C. ps_0607 gene as a LAMP target was straight forward since it had been suggested for such a purpose in previous studies (Voigt, Schöfl & Saluz, 2012; Opota et al., 2015), For C. pecorum, however, we utilised our ongoing comparative genomics to select C. pecorum-specific and conserved C.pec_HP gene described in this study for the first time. In silico analyses and assay development confirmed species-specificity of this gene and its suitability for use in diagnostic assays. Previously published C. pecorum diagnostic assays targeted highly polymorphic genes such as ompA (Higgins et al., 2012; Yang et al., 2014), which may require the use of probes due to sequence variation, prolonging the detection time and increasing diagnostic costs. Our routinely used in house C. pecorum-specific assay which targets a 204 bp 16S rRNA fragment (Marsh et al., 2011; Wan et al., 2011) was simpler to use, however we have shown that this assay may cross-react with other related chlamydial species due to a lack of sufficient sequence variation in the region of the 16S rRNA gene targeted (Bachmann, Polkinghorne & Timms, 2014). For koala diagnostics where C. pecorum is the most abundant and prevalent chlamydial organism (Polkinghorne, Hanger & Timms, 2013), this cross-reactivity may not be of a big concern. For the veterinary diagnosis of infections in livestock where co-infections with several chlamydial species are common (Lenzko et al., 2011; Reinhold, Sachse & Kaltenboeck, 2011), this assay may be less suitable. Using the C. pecorum-specific HP gene as a target in different diagnostic assays would hence seem promising.

Performance of the C. psittaci and C. pecorum LAMP assays

The sensitivity of the LAMP assays was evaluated using 5 µL cultured C. psittaci and C. pecorum gDNA in 10-fold serial dilutions as a template in assays performed in triplicate in separate runs. The limits of detection of the LAMP assays were conservatively 10 copies for C. psittaci, with 3/3 (100%) positive amplification for 10 copy dilutions for C. psittaci, and one copy for C. pecorum, with 3/3 (100%) positive amplifications for a single copy dilution of C. pecorum DNA (Tables 2 and 3). In the final and optimised LAMP assays, the mean amplification time detecting the lower limit (a single copy) for C. psittaci was 14.23 min with an average 84.45 °C melt (Table 2) while, for C. pecorum, it was 24 min with an average 83.42 °C melt (Table 3). Comparing the two newly developed assays, C. psittaci LAMP had the faster run time than that of C. pecorum LAMP. This difference in assays kinetics could be attributed to the improved C. psittaci LAMP primers design, as they were predicted by the LAMP Designer software (Nagamine, Hase & Notomi, 2002). As we additionally designed Loop primers for C. pecorum, we can anticipate an improvement in the C. pecorum assay kinetics by re-designing the loop primers (e.g., extending the sequence to 20–22 bp), as well as testing LAMP mixes in different ratios and with improved polymerases.
Table 2

C. psittaci LAMP assay sensitivity.

DilutiondTime to amplify (min)Melt (°C)Time (Mean + SD)Melt (Mean + SD)
1065.1584.435.10, 0.0984.49, 0.08
1065.0084.46
1065.1584.58
1056.3084.346.30, 0.1584.37, 0.06
1056.4584.33
1056.1584.43
1047.1584.597.25, 0.0984.56, 0.04
1047.3084.58
1047.3084.51
1038.4584.468.25, 0.17384.44, 0.01
1038.1584.43
1038.1584.44
1009.1584.489.30, 0.1584.46, 0.06
1009.3084.39
1009.4584.51
1012.0084.4111.33, 0.5884.38, 0.03
1011.0084.35
1011.0084.39
116.0084.4414.23, 2.5184.34, 0.14
10.000
112.4584.24
0.125.2584.20
0.1b84.20
0.184.20c

Notes.

The assay was performed in Genie III Real-time fluorometer, with the amplification times and annealing temperatures recorded at the end of each run. The samples were tested in three different runs.

No amplification detected.

No amplification, but melt and annealing curve recorded.

Template was serially diluted C. psittaci CR009 gDNA which genome copy number was determined by qPCR.

Table 3

C. pecorum LAMP assay sensitivity.

DilutionfTime to amplify (min)Melt (°C)Time (Mean + SD)Melt (Mean + SD)
107ka10.0083.2310.23, 0.3283.30, 0.1
107k10.4583.37
106k13.1583.5712.92, 0.4083.51, 0.16
106sb13.1583.33
106cc12.4583.62
105k14.0083.5214.10, 0.1783.48, 0.11
105s14.0083.35
105c14.3083.57
104k15.4583.5616.30, 0.7883.44, 0.11
104s16.4583.33
104c17.0083.42
103k19.0083.5018.87, 1.3583.45, 0.06
103s17.4583.39
103c20.1583.47
100k20.1583.4720.35, 2.0083.33, 0.21
100s18.4583.09
100c22.4583.42
10k22.3083.5222.43, 1.5083.42, 0.1
10s21.0083.42
10c24.0083.33
1k23.1583.5223.92, 2.1183.41, 0.12
1s22.3083.42
1c26.3083.28
0.1k36.0083.4134.65, 1.9183.39, 0.06
0.1sd83.43
0.1c33.3083.33

Notes.

Koala Marsbar isolate.

Sheep IPA isolate.

Cattle E58 isolate.

No amplification, but melt and annealing curve recorded.

The assay was performed in Genie III Real-time fluorometer, with the amplification times and annealing temperatures recorded at the end of each run. The samples were tested in different runs.

Template was serially diluted C. pecorum gDNA which genome copy number was determined by qPCR.

Notes. The assay was performed in Genie III Real-time fluorometer, with the amplification times and annealing temperatures recorded at the end of each run. The samples were tested in three different runs. No amplification detected. No amplification, but melt and annealing curve recorded. Template was serially diluted C. psittaci CR009 gDNA which genome copy number was determined by qPCR. Notes. Koala Marsbar isolate. Sheep IPA isolate. Cattle E58 isolate. No amplification, but melt and annealing curve recorded. The assay was performed in Genie III Real-time fluorometer, with the amplification times and annealing temperatures recorded at the end of each run. The samples were tested in different runs. Template was serially diluted C. pecorum gDNA which genome copy number was determined by qPCR. In order to test the reproducibility of our LAMP assays, we tested a subset of C. pecorum and C. psittaci PCR positive samples (Table 4). All samples were run in a “blind fashion”, in triplicate and in separate runs by two different operators. For both assays, the amplification times and melts of each sample between the runs were very similar, with 0 to 1.5 min (SDs ranging from 0–0.98) difference in amplification times for each sample, and 0.03 to 0.83 °C (SDs ranging from 0.02–0.26) difference in melt for each sample. Congruence between the runs performed by different operators indicates that both LAMP assays described in this study are highly reproducible, and can detect the target organism in less than 30 min even when in low infectious loads of <10 copies.
Table 4

Reproducibility of the LAMP testing using clinical and cultured samples.

SamplesRunaTime to amplify (min)Melt (°C)Time (Mean + SD)Melt (Mean + SD)
C. pecorumpositive samples
Koala rectal swab120.1583.4420.53, 0.5483.32, 0.16
220.3083.37
321.1583.14
Marsbar DNA113.5083.5013.27, 0.2083.55, 0.06
213.1583.52
313.1583.62
Koala A2 DNA112.0083.3511.43, 0.5183.41, 0.05
211.0083.45
311.3083.43
RI koala UGT swab117.0083.3417.72, 0.6283.21, 0.12
218.0083.21
318.1583.09
L14 DNA113.1583.5313.15, 083.50, 0.02
213.1583.50
313.1583.48
HsLuRz DNA113.4583.4913.63, 0.3283.40, 0.08
213.4583.36
314.0083.34
K20 cloaca swab122.0082.8322.2, 0.2383.01, 0.19
222.1583.00
322.4583.20
C. psittacipositive samples
Cr009 DNA16.4584.306.40, 0.0984.33, 0.03
26.4584.36
36.3084.34
HoRE DNA15.0084.465.10, 0.0884.45, 0.14
25.1584.58
35.1584.30
B2 DNA110.3084.0810.10, 0.1784.17, 0.08
210.0084.20
310.0084.24
Horse placental swab111.1582.9010.58, 0.4983.19, 0.26
210.3083.42
310.3083.24
Horse_pl DNA110.3084.5310.87, 0.9884.41, 0.18
212.0084.21
310.3084.50

Notes.

The assay was performed in Genie III Real-time fluorometer, with the amplification times and annealing temperatures recorded at the end of each run. The samples were tested in three different runs by two different operators.

Notes. The assay was performed in Genie III Real-time fluorometer, with the amplification times and annealing temperatures recorded at the end of each run. The samples were tested in three different runs by two different operators.

Pathogen detection in clinical samples using newly developed LAMP

For C. psittaci, a total of 26 DNA extracts from clinical samples were tested with both C. psittaci LAMP and qPCR assays (Table S2). For these analyses, samples with >20 min amplification time were considered negative for LAMP, while for qPCR, samples with <20 genome copy/reaction and/or >30 Ct (quantification cycle) were considered negative, based on the qPCR standard curve and the number of running cycles used for this testing. As observed in Table S2 and based on above cut-off values, 24/26 (92.3%) samples were congruent between the two tests, with 11 samples positive and 13 samples negative by both (Table 5). For 2/26 (7.7%) where there was disagreement, one sample was LAMP positive but qPCR negative, and another was qPCR positive but C. psittaci LAMP negative. Based on these results, the Kappa value was calculated at 0.85 (95% CI [0.64–1.05]) indicating an almost perfect agreement between the tests. The overall sensitivity of the C. psittaci LAMP was 91.7% (Clopper–Pearson 95% CI [0.62–0.99]) and with 92.9% (Clopper–Pearson 95% CI [0.66–0.99]) specificity, compared to the qPCR used in this study. In addition, a subset of 23 samples was also tested independently by a third party. Using a cut off of >Ct 39 as negative, 19/23 (82.60 %) of these test results were in congruence with our C. psittaci LAMP results (Table S2).
Table 5

Comparison of the C. psittaci LAMP and qPCR methods for the organism detection in clinical samples.

TestqPCR +veqPCR −veqPCR Total
LAMP +ve11112
LAMP −ve11314
LAMP Total121426
For C. pecorum, we tested a total of 63 DNA extracts from clinical samples from several animal hosts by both LAMP and qPCR (Table S3). For these analyses, samples with >30 min amplification time were considered negative for LAMP, while for qPCR, samples with <35 genome copy /reaction and/or >30 Ct were considered negative based on the standard curve and number of run cycles used for this testing. For the 63 clinical samples, the overall congruence was 84.1% with a Kappa value of 0.68 (95% CI [0.50–0.86]), indicating substantial agreement between the tests. Congruent results between tests were obtained for 53 samples, while there were 10 discrepant samples using the above cut off for C. pecorum (Table 6). The overall sensitivity of C. pecorum LAMP was 90.6 % (Clopper–Pearson 95% CI [0.75–0.98]), while specificity was 77.4 % (Clopper–Pearson 95% CI [0.59–0.90]) in comparison to the qPCR assay. A subset of 36 C. pecorum samples was also tested in a thermal cycler using the newly developed LAMP and results were determined as an end point detection. For this experiment, 34/36 (94.4%) samples were congruent between LAMP performed in fluorometer and in a thermal cycler (Table S3), demonstrating the robustness of the C. pecorum LAMP (Fig. S2).
Table 6

Comparison of the C. pecorum LAMP and qPCR methods for the organism detection in clinical samples.

Test16s +ve16s −ve16s Total
LAMP +ve29736
LAMP −ve32427
LAMP Total323163
Notes. LAMP results are expressed as time to amplify (min) and melt (°C). qPCR results are expressed as copies/reaction and Ct value. RNA Later swabs. Considering that the qPCR assay used in this study to quantify and detect C. psittaci is chlamydial genus rather species specific (Everett, Bush & Andersen, 1999), high congruence observed for C. psittaci assays could be attributed to testing a limited set of samples taken from hosts with presumptive C. psittaci chlamydiosis. Lower congruence between the C. pecorum-specific assays could be due to technical and experimental aspects and characteristics (such as the assay efficiency, analytical sensitivity, template preparation) (Bustin et al., 2010) of the C. pecorum 16S qPCR assay used in this study. As a sidenote, we also evaluated the use of C. psittaci and C. pecorum LAMP targets (263 bp of the C. ps_0607 and 209 bp C. pec_HP genes, respectively) using outer F3 and B3 primers in a fluorescence-based (SybrGreen) qPCR assays, if needed to estimate infectious loads of the pathogen. In this preliminary analyses, both targets seem suitable for use in qPCR assays as well, as we were able to detect low infectious load up to 10 copies/reaction in a sample.

Rapid swab processing

Rapid swab processing and using the swab suspension directly in LAMP assays were previously successfully evaluated for testing for respiratory syncytial virus from nasopharyngeal swabs (Mahony et al., 2013) and rapid detection of Streptococcus agalactiae in vaginal swabs (McKenna et al., 2017). A recent study also demonstrated that C. trachomatis can be detected directly from urine samples using the LAMP method (Jevtusevskaja et al., 2016). In this study, we also evaluated rapid swab processing without DNA extraction in order to begin to assess the POC potential of these assays. A total of 18 swabs taken from conjunctival and urogenital sites from koalas with presumptive chlamydiosis, of which four were stored in RNA Later and 14 were dry, were used for this experiment (Table 7). Vigorously vortexed and heated swab suspension samples were directly used as a template in both C. pecorum LAMP reaction performed in fluorometer and qPCR assay. We also performed DNA extraction from the swabs to be used as a comparison to rapid swab processing. We did not detect C. pecorum DNA in any of the RNA Later suspensions either by LAMP nor qPCR assay (Table 7), in contrast to detecting C. pecorum in 50% (2/4) of the DNA extracts from the swabs by both methods. Using the rapidly processed swab suspension as a template, C. pecorum was detected in 6/14 by LAMP, and only 2/14 by qPCR (Table 7). The swab suspension LAMP results were 92.8% (13/14) congruent to the LAMP results and 85.7% congruent (12/14) to the qPCR results using the swab’s paired DNA sample. In order to evaluate the potential presence of inhibitors in our samples, we “spiked” negative swab suspensions and its paired DNA samples with known amounts of C. pecorum (1 × 104 copies/reaction). As observed in Table 7, we detected C. pecorum by both LAMP and qPCR in “spiked” negative samples derived from dry swabs. No C. pecorum was detected in “spiked” RNA Later swab suspension, indicating the potential presence of inhibitors in these reactions. Our results suggest that the LAMP assays are capable of amplifying specific amplification products from crude DNA extracts.
Table 7

Comparison of C. pecorum LAMP and qPCR for organism detection using rapidly processed swab samples and their DNA extracts.

SampleLAMPa result for swab suspensionqPCRb result for swab suspensionLAMP result for DNA extractqPCR result for DNA extractLAMP result for “spiked” swab suspensionLAMP result for “spiked” DNA extractqPCR result for “spiked” swab suspensionqPCR result for “spiked” DNA extract
K1 ocularcNEGNEG0.00/83.49NEGNEGNEG
K6 ocularcNEGNEG21.00/83.233 × 103 (Ct 20)NEGNEG
K9 ocularcNEGNEG25.45/83.39287 (Ct 24)NEGNEG
K2 ocularcNEGNEGNEGNEGNEGNEG
R1 eye25.45/83.39222 (Ct 25)20.15/83.27750 (Ct 24)
R1 cloaca30.00/83.34NEGNEGNEG11.15/83.4712.15/83.425 × 103 (Ct 17)1.5 × 103 (Ct 18)
K eye27.00/83.15NEG0.00/83.35NEG
Koala 2 eyeNEGNEGNEGNEG11.00/83.5111.00/83.401.2 × 103 (Ct 19)1.1 × 104 (Ct 15)
Koala 2 cloaca27.30/83.77116 (Ct 26)21.30/83.49375 (Ct 25)
Will Cloaca0.00/83.77NEGNEGNEG12.00/83.4511.00/83.341.5 × 103 (Ct 19)8 × 103 (Ct 17)
23117 Eye21.30/83.20NEG23.15/83.23150 (Ct 25)
23117 Cloaca22.00/83.29NEG24.00/83.1590 (Ct 27)
Flyn eyeNEGNEGNEGNEG12.30/83.5011.00/83.351.9 × 103 (Ct 18)8.3 × 103 (Ct 16)
Tyke eyeNEGNEGNEGNEG12.00/83.4410.45/83.401.3 × 103 (Ct 19)9 × 103 (Ct 16)
Bill eyeNEGNEGNEGNEG12.15/83.4910.45/83.341.2 × 103 (Ct 19)1 × 104 (Ct 15)
Ray eyeNEGNEGNEGNEG12.45/83.4911.00/83.404.7 × 103 (Ct 17)1 × 104 (Ct 15)
Ray cloacaNEGNEGNEGNEG12.15/83.4311.00/83.30700 (Ct 20)9 × 103 (Ct 16)
Koala F EyeNEGNEGNEGNEG11.45/83.4511.00/83.351.3 × 103 (Ct 19)1.1 × 104 (Ct 15)

Notes.

LAMP results are expressed as time to amplify (min) and melt (°C).

qPCR results are expressed as copies/reaction and Ct value.

RNA Later swabs.

Further work is additionally required to enhance the POC capabilities of these new chlamydial LAMP assays to meet the clinical need including (i) the evaluation of rapid swab processing methods using commercially available DNA release portable devices and/or sample preparation using microfluidic support; (ii) alternative amplification detection methods such as visible colorimetric or turbidimetric change and/or solid-phase ‘dipstick’ tests (Maffert et al., 2017). With further development and the aforementioned focus on the preparation of these assays at the POC (Parida et al., 2008; Tomita et al., 2008), it is anticipated that both LAMP tests described in this study may fill an important niche in the repertoire of ancillary diagnostic tools available to clinicians.

C. psittaci and C. pecorum LAMP targets sequences alignment

A: A 263bp fragment of the Cps_0607 gene alignment; B: A 209bp fragment of the C.pec_HP gene alignment. SNPs in the alignments are highlighted. Click here for additional data file.

End-point detection of C. pecorum and C. psittaci LAMP performed on the thermal cycle

(A) C. pecorum LAMP sensitivity. In lanes 1: DNA marker VIII, 2: C. pecorum 105 genome copy number dilution, 3: 104 genome copy number dilution, 4: 103 genome copy number dilution, 5: 102 genome copy number dilution, 6: 101 genome copy number dilution, 7: 100 genome copy number dilution, 8: 10−1 genome copy number dilution, 9: 10−2 genome copy number dilution, 10: Negative (water as template), 11: Negative (mix only); (B) C. pecorum LAMP testing of clinical samples. In lanes 1: koala swab sample Chloe U, 2: Chloe R, 3: koala swab sample K61528, 4: K68199, 5: K67797, 6: K52866, 7: K60652, 8 and 11: DNA Marker VIII, 9: C. pecorum koala Marsbar strain, 10: Negative (water), 12: sheep eye swab S87, 13: Lamb1 eye swab, 14: cattle rectal swab 18R, 15: Cow brain sample, and 16: cattle rectal swab 20R; (C) C. psittaci LAMP sensitivity. In lanes 1: DNA marker VIII, 2: C. psittaci 105 genome copy number dilution, 3: 104 genome copy number dilution, 4: 103 genome copy number dilution, 5: 102 genome copy number dilution, 6: 101 genome copy number dilution, 7: 100 genome copy number dilution, 8: 10−1 genome copy number dilution, 9: 10−2 genome copy number dilution, 10: Negative (water as template), 11: Negative (mix only); (D) C. psittaci LAMP testing of clinical samples. In lanes 1: empty, 2: DNA Marker VIII, 3: Horse 14092/1, 4: Horse 10272/3, 5: Horse 13234/3, 6: Horse 11310/2, 7: Horse 12004/2, 8: Horse 12818/3, 9: Horse 11786/3, 10: Horse 11035/1, 11: Horse 13237/3, 12: Pigeon p12, 13: C. psittaci B2, 14: Negative (water as template); (E) C. pecorum LAMP specificity. In lanes 1: C. psittaci, 2: C. pneumoniae, 3: C. abortus, 4: C. suis, 5: C. trachomatis, 6: Chlamydiales positive sample (Fritchea spp.), 7 and 10: DNA Marker VIII, 8: C. pecorum koala Marsbar strain, 9: C. pecorum E58 cattle strain, 11 - 16: Gram Neg and Gram Pos bacteria, as follows: Escherichia coli, Enterococcus feacalis, Fusobacterium spp., Prevotella bivia, Staphylococcus epidermidis, Streptococcus spp., 17: empty, and 18-19: Negative (water and mix only). Click here for additional data file. Click here for additional data file. Click here for additional data file. Click here for additional data file.
  45 in total

1.  Accelerated reaction by loop-mediated isothermal amplification using loop primers.

Authors:  K Nagamine; T Hase; T Notomi
Journal:  Mol Cell Probes       Date:  2002-06       Impact factor: 2.365

2.  Longitudinal prevalence and faecal shedding of Chlamydia pecorum in sheep.

Authors:  Rongchang Yang; Caroline Jacobson; Graham Gardner; Ian Carmichael; Angus J D Campbell; Una Ryan
Journal:  Vet J       Date:  2014-05-29       Impact factor: 2.688

Review 3.  Loop-mediated isothermal amplification (LAMP): principle, features, and future prospects.

Authors:  Tsugunori Notomi; Yasuyoshi Mori; Norihiro Tomita; Hidetoshi Kanda
Journal:  J Microbiol       Date:  2015-01-04       Impact factor: 3.422

Review 4.  Chlamydiaceae in cattle: commensals, trigger organisms, or pathogens?

Authors:  Petra Reinhold; Konrad Sachse; Bernhard Kaltenboeck
Journal:  Vet J       Date:  2010-10-25       Impact factor: 2.688

5.  Loop-mediated isothermal amplification (LAMP) of gene sequences and simple visual detection of products.

Authors:  Norihiro Tomita; Yasuyoshi Mori; Hidetoshi Kanda; Tsugunori Notomi
Journal:  Nat Protoc       Date:  2008       Impact factor: 13.491

Review 6.  Avian Chlamydiosis Zoonotic Disease.

Authors:  Monika Szymańska-Czerwińska; Krzysztof Niemczuk
Journal:  Vector Borne Zoonotic Dis       Date:  2016-01-07       Impact factor: 2.133

7.  Rapid and visual Chlamydia trachomatis detection using loop-mediated isothermal amplification and hydroxynaphthol blue.

Authors:  I Choopara; N Arunrut; W Kiatpathomchai; D Dean; N Somboonna
Journal:  Lett Appl Microbiol       Date:  2016-11-21       Impact factor: 2.858

8.  Real-time PCR detection and quantitation of Chlamydophila psittaci in human and avian specimens from a veterinary clinic cluster.

Authors:  J M Branley; B Roy; D E Dwyer; T C Sorrell
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2008-01-09       Impact factor: 3.267

9.  Geneious Basic: an integrated and extendable desktop software platform for the organization and analysis of sequence data.

Authors:  Matthew Kearse; Richard Moir; Amy Wilson; Steven Stones-Havas; Matthew Cheung; Shane Sturrock; Simon Buxton; Alex Cooper; Sidney Markowitz; Chris Duran; Tobias Thierer; Bruce Ashton; Peter Meintjes; Alexei Drummond
Journal:  Bioinformatics       Date:  2012-04-27       Impact factor: 6.937

10.  Multilocus sequence typing identifies an avian-like Chlamydia psittaci strain involved in equine placentitis and associated with subsequent human psittacosis.

Authors:  Martina Jelocnik; James Branley; Jane Heller; Shane Raidal; Susan Alderson; Francesca Galea; Melinda Gabor; Adam Polkinghorne
Journal:  Emerg Microbes Infect       Date:  2017-02-15       Impact factor: 7.163

View more
  20 in total

1.  Development and application of two multiplex real-time PCR assays for detection and speciation of bacterial pathogens in the koala.

Authors:  Lyndal S Hulse; Danica Hickey; Jessica M Mitchell; Kenneth W Beagley; William Ellis; Stephen D Johnston
Journal:  J Vet Diagn Invest       Date:  2018-04-09       Impact factor: 1.279

2.  Changes in Endogenous and Exogenous Koala Retrovirus Subtype Expression over Time Reflect Koala Health Outcomes.

Authors:  Bonnie L Quigley; Samuel Phillips; Olusola Olagoke; Amy Robbins; Jonathan Hanger; Peter Timms
Journal:  J Virol       Date:  2019-08-28       Impact factor: 5.103

3.  A 25-year retrospective study of Chlamydia psittaci in association with equine reproductive loss in Australia.

Authors:  Rumana Akter; Fiona M Sansom; Charles M El-Hage; James R Gilkerson; Alistair R Legione; Joanne M Devlin
Journal:  J Med Microbiol       Date:  2021-02       Impact factor: 2.472

4.  Evaluation of fluorimetry and direct visualization to interpret results of a loop-mediated isothermal amplification kit to detect Leishmania DNA.

Authors:  Ana V Ibarra-Meneses; Israel Cruz; Carmen Chicharro; Carmen Sánchez; Sylvain Biéler; Tobias Broger; Javier Moreno; Eugenia Carrillo
Journal:  Parasit Vectors       Date:  2018-04-17       Impact factor: 3.876

5.  A Sarcoptes scabiei specific isothermal amplification assay for detection of this important ectoparasite of wombats and other animals.

Authors:  Tamieka A Fraser; Scott Carver; Alynn M Martin; Kate Mounsey; Adam Polkinghorne; Martina Jelocnik
Journal:  PeerJ       Date:  2018-07-27       Impact factor: 2.984

6.  Real-time loop-mediated isothermal amplification for rapid detection of Enterocytozoon hepatopenaei.

Authors:  Shao-Xin Cai; Fan-De Kong; Shu-Fei Xu; Cui-Luan Yao
Journal:  PeerJ       Date:  2018-12-04       Impact factor: 2.984

7.  Molecular and serological dynamics of Chlamydia pecorum infection in a longitudinal study of prime lamb production.

Authors:  Sankhya Bommana; Evelyn Walker; Marion Desclozeaux; Martina Jelocnik; Peter Timms; Adam Polkinghorne; Scott Carver
Journal:  PeerJ       Date:  2018-01-25       Impact factor: 2.984

8.  An epizootic of Chlamydia psittaci equine reproductive loss associated with suspected spillover from native Australian parrots.

Authors:  Cheryl Jenkins; Martina Jelocnik; Melinda L Micallef; Francesca Galea; Alyce Taylor-Brown; Daniel R Bogema; Michael Liu; Brendon O'Rourke; Catherine Chicken; Joan Carrick; Adam Polkinghorne
Journal:  Emerg Microbes Infect       Date:  2018-05-16       Impact factor: 7.163

9.  Diagnostic accuracy of LAMP assay for HBV infection.

Authors:  Chu-Mao Chen; Shi Ouyang; Li-Ying Lin; Li-Juan Wu; Tian-Ao Xie; Juan-Jiang Chen; Zhen-Xing Li; Guo-Dong Zhu; Tian-Xing Ji; Zhi-Yong Pan; Yong Xia; Xu-Guang Guo
Journal:  J Clin Lab Anal       Date:  2020-03-10       Impact factor: 2.352

10.  Koala immunogenetics and chlamydial strain type are more directly involved in chlamydial disease progression in koalas from two south east Queensland koala populations than koala retrovirus subtypes.

Authors:  Amy Robbins; Jonathan Hanger; Martina Jelocnik; Bonnie L Quigley; Peter Timms
Journal:  Sci Rep       Date:  2020-09-14       Impact factor: 4.996

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.