| Literature DB >> 28924598 |
Michael Riverso1, Yaseen B Perbtani1, Jonathan J D Shuster2, Joydeep Chakraborty3, Tony S Brar3, Mitali Agarwal3, Han Zhang3, Anand Gupte1, Shailendra S Chauhan1, Christopher E Forsmark1, Peter V Draganov1, Dennis Yang1.
Abstract
BACKGROUND AND STUDY AIMS: Sessile serrated adenomas (SSA) and traditional serrated adenomas (TSA) have been increasingly recognized as precursors of colorectal cancer. The aim of this study was to compare the effect of carbon dioxide insufflation (CO 2 I) vs. room air insufflation (AI) on serrated polyp detection rate (SPDR) and to identify factors associated with SPDR. PATIENTS AND METHODS: Single-center retrospective cohort study of 2083 screening colonoscopies performed with AI (November 2011 through January 2013) or CO 2 I (February 2013 to June 2015). Data on demographics, procedure characteristics and histology results were obtained from a prospectively maintained endoscopy database and chart review. SPDR was defined as proportion of colonoscopies in which ≥ 1 SSA, TSA or hyperplastic polyp (HP) ≥ 10 mm in the right colon was detected. Multi-variate analysis (MVA) was performed to identify predictors of SPDR.Entities:
Year: 2017 PMID: 28924598 PMCID: PMC5597937 DOI: 10.1055/s-0043-116382
Source DB: PubMed Journal: Endosc Int Open ISSN: 2196-9736
Baseline characteristics.
| Variable | Overall |
CO
2
I
| AI |
|
| Age, mean ± SD (years) | 59 ± 8.7 | 59.1 ± 8.7 | 58.8 ± 8.9 | 0.44 |
| Male, n(%) | 959 (46) | 675 (46.4) | 284 (44.8) | 0.53 |
| BMI, mean ± SD, kg/m 2 | 31.7 ± 9 | 31.6 ± 8.8 | 32.1 ± 9.3 | 0.21 |
| ASA score | ||||
I | 74 (3.6) | 50 (3.5) | 24 (3.8) | 0.19 |
II | 902 (43.3) | 619 (42.7) | 283 (44.6) | |
III | 1022 (49) | 711 (49.1) | 311 (49.1) | |
IV | 85 (4.1) | 69 (4.8) | 16 (2.5) | |
| Trainee involvement, n(%) | 861 (41.3) | 550 (38) | 311 (49) | < .0001 |
| Quality of bowel preparation | ||||
Excellent | 281 (13.5) | 180 (12.4) | 101 (15.9) | 0.002 |
Good | 1210 (58.1) | 829 (57.2) | 381 (60.1) | |
Fair | 429 (20.6) | 319 (22.0) | 110 (17.4) | |
Poor | 163 (7.8) | 121 (8.4) | 42 (6.6) | |
| Cecal intubation rate, n (%) | 2049 (98.4) | 1421 (98.1) | 628 (99.1) | 0.1 |
| Total procedure time, mean ± SD (minutes) | 20 ± 9.7 | 19.6 ± 9.6 | 21 ± 9.9 | 0.002 |
| Scope withdrawal time, mean ± SD (minutes) | 9.6 ± 6.6 | 9.4 ± 6.4 | 10.2 ± 6.9 | 0.03 |
AI, air insufflation; ASA, American Society of Anesthesiologists; BMI, body mass index; SD, standard deviation
Colonoscopy performance per endoscopist.
| Endoscopist | Colonoscopies (n) | PDR (%) | ADR (%) | SPDR (%) |
| 1 | 3 | 0 | 0 | 0 |
| 2 | 10 | 60 | 60 | 0 |
| 3 | 9 | 66.7 | 55.6 | 0 |
| 4 | 13 | 69.2 | 53.9 | 0 |
| 5 | 86 | 56.7 | 34.9 | 3.5 |
| 6 | 8 | 25 | 0 | 0 |
| 7 | 24 | 50 | 45.8 | 4.2 |
| 8 | 26 | 46.2 | 26.9 | 3.9 |
| 9 | 45 | 44.4 | 35.6 | 0 |
| 10 | 31 | 61.3 | 48.4 | 6.5 |
| 11 | 46 | 39.1 | 23.9 | 0 |
| 12 | 65 | 47.7 | 35.4 | 12.3 |
| 13 | 14 | 35.7 | 28.6 | 0 |
| 14 | 48 | 39.6 | 31.3 | 4.2 |
| 15 | 198 | 38.4 | 28.8 | 3.5 |
| 16 | 317 | 48.3 | 27.4 | 3.2 |
| 17 | 208 | 48.1 | 36.5 | 3.9 |
| 18 | 199 | 43.7 | 34.7 | 3.5 |
| 19 | 237 | 44.7 | 24.1 | 2.5 |
| 20 | 496 | 41.9 | 29.6 | 4.4 |
| Overall | 2083 | 45 | 30.9 | 3.7 |
ADR, adenoma detection rate; PDF, polyp detection rate; SPDR, serrated polyp detection rate
Fig. 1Detection rates between patients undergoing screening colonoscopy with AI vs. CO 2 I.
Variables associated with SPDR.
| Clinical variable | Univariate analysis | Multivariate analysis | ||
| OR (95 % CI) |
| OR (95 % CI) |
| |
| Age (years) | 1.0 (0.97 – 1.03) | 0.93 | 1.02 (0.99 – 1.05) | 0.293 |
| Gender (male vs female) | 0.828 (0.52 – 1.31) | 0.42 | 1.23 (0.70 – 2.16) | 0.47 |
| BMI (kg/m 2 ) | 1.04 (1.02 – 1.06) | 0.0008 | 1.05 (1.02 – 1.09) | 0.0004 |
| ASA score (1 vs 2/3/4) | 2.87 (0.39 – 20.9) | 0.30 | 4.03 (0.44 – 36.6) | 0.22 |
| Trainee involvement (yes vs no) | 1.26 (0.80 – 1.98) | 0.33 | 0.71 (0.39 – 1.30) | 0.27 |
| Cecal intubation (yes vs no) | 1.27 (0.17 – 9.41) | 0.82 | --- | --- |
| Scope withdrawal time (per minute) | 1.10 (1.07 – 1.13) | < .0001 | 1.11 (1.07 – 1.16) | < 0.0001 |
| Total procedure time (per minute) | 1.05 (1.03 – 1.07) | < .0001 | 1.01 (0.98 – 1.05) | 0.59 |
| Quality of bowel preparation | 1.08 (0.65 – 1.77) | 0.77 | 0.70 (0.35 – 1.42) | 0.32 |
| Type of scope (high-definition vs standard) | 1.64 (0.39 – 6.83) | 0.50 | --- | --- |
| Type of sedation (conscious vs moderate anesthesia care) | 2.13 (0.92 – 4.95) | 0.08 | 1.14 (0.38 – 3.42) | 0.82 |
| Method of insufflation (CO 2 I vs AI) | 3.91 (1.87 – 8.20) | 0.0003 | 9.52 (3.05 – 30.3) | 0.0001 |
AI, air insufflation; ASA, American Society of Anesthesiologists; BMI, body mass index; SPDR, serrated polyp detection rate