An accurate, sensitive, precise, reliable, and quick method for the determination of cholesterol content by high-performance thin layer chromatography is developed. In this method, aluminum-backed precoated silica gel 60 F254 plates were used as the stationary phase and the samples were sprayed with the help of CAMAG sample applicator Linomat 5. The chromatogram was developed with the mobile phase consisting of chloroform:methanol (9.5:0.5, v/v). The samples were detected using CAMAG Scanner 4 and evaluated using the method developed on winCATS software. Densitometric analysis of cholesterol was performed in absorbance mode at 200 nm. In this solvent system, cholesterol gave a compact spot with an Rf value of 0.63 ± 0.03. The linear regression analysis of data for the calibration curve showed good linearity over a concentration range of 2-7 μg/spot with a regression value of 0.99933 and standard deviation of 1.44%. The limit of detection and limit of quantification were found to be 100 ng/spot and 500 ng/spot, respectively. Using the developed method, the concentration of cholesterol in the saponified and unsaponified egg yolk sample was determined. This method was found to be reproducible and can even be used for samples containing complex matrices.Entities:
Keywords: cholesterol; densitometric analysis; egg yolk; high-performance thin layer chromatography method
Year: 2014 PMID: 28911376 PMCID: PMC9351763 DOI: 10.1016/j.jfda.2014.07.006
Source DB: PubMed Journal: J Food Drug Anal Impact factor: 6.157
Fig. 1Structure of cholesterol.
Fig. 2Calibaration curve shows linear relation for cholesterol.
Precision of the HPTLC method developed for cholesterol determination.
| Sample | Concentration (μg/spot) | Intraday | Interday | ||
|---|---|---|---|---|---|
|
|
| ||||
| Accuracy (%) | Precision (%RSD) | Accuracy (%) | Precision (%RSD) | ||
| Cholesterol | 2 | 99.38 ± 0.73 | 0.12 | 99.03 ± 0.52 | 0.23 |
| 3 | 99.27 ± 1.29 | 0.26 | 99.12 ± 0.38 | 0.18 | |
| 5 | 98.72 ± 1.09 | 0.39 | 98.81 ± 0.20 | 0.57 | |
HPTLC = high-performance thin layer chromatography; %RSD = percentage relative standard deviation.
Mean of three replicates.
Fig. 3Densitogram at 200 nm showing the specificity of cholesterol (R = 0.63 ± 0.03) in saponified egg yolk sample and blood serum.
Recovery of cholesterol showing the accuracy of the method.
| Spiking level | Cholesterol added (ng) | Cholesterol found (ng), mean ± SD, | % Recovery (mean ± SD, |
|---|---|---|---|
| 0 | 1908 ± 1.862 | ||
| 1 | 300 | 2187 ± 2.130 | 99.04 ± 0.41 |
| 2 | 500 | 2421 ± 1.074 | 100.53 ± 0.28 |
SD = standard deviation.