Literature DB >> 21641446

A fast and highly sensitive detection of cholesterol using polymer microfluidic devices and amperometric system.

Nipapan Ruecha1, Weena Siangproh, Orawon Chailapakul.   

Abstract

In this work, the rapid detection of cholesterol using poly(dimethylsiloxane) microchip capillary electrophoresis, based on the coupling of enzymatic assays and electrochemical detection, was developed. Direct amperometric detection for poly(dimethylsiloxane) (PDMS) microchip capillary electrophoresis was successfully applied to quantify cholesterol levels. Factors influencing the performance of the method (such as the concentration and pH value of buffer electrolyte, concentration of cholesterol oxidase enzyme (ChOx), effect of solvent on the cholesterol solubility, and interferences) were carefully investigated and optimized. The migration time of hydrogen peroxide, product of the reaction, was less than 100 s when using 40 mM phosphate buffer at pH 7.0 as the running buffer, a concentration of 0.68 U/mL of the ChOx, a separation voltage of +1.6 kV, an injection time of 20s, and a detection potential of +0.5 V. PDMS microchip capillary electrophoresis showed linearity between 38.7 μg/dL (1 μM) and 270.6 mg/dL (7 mM) for the cholesterol standard; the detection limit was determined as 38.7 ng/dL (1 nM). To demonstrate the potential of this assay, the proposed method was applied to quantify cholesterol in bovine serum. The percentages of recoveries were assessed over the range of 98.9-101.8%. The sample throughput was found to be 60 samples per hour. Therefore, PDMS microchip capillary electrophoresis, based on the coupling of enzymatic assays and electrochemical detection, is very rapid, accurate and sensitive method for the determination of cholesterol levels.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21641446     DOI: 10.1016/j.talanta.2011.02.040

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  5 in total

1.  Multiple enzyme-doped thread-based microfluidic system for blood urea nitrogen and glucose detection in human whole blood.

Authors:  Yu-An Yang; Che-Hsin Lin
Journal:  Biomicrofluidics       Date:  2015-03-20       Impact factor: 2.800

Review 2.  Applications of microfluidics and microchip electrophoresis for potential clinical biomarker analysis.

Authors:  Jayson V Pagaduan; Vishal Sahore; Adam T Woolley
Journal:  Anal Bioanal Chem       Date:  2015-04-09       Impact factor: 4.142

Review 3.  Microfluidics as a Novel Tool for Biological and Toxicological Assays in Drug Discovery Processes: Focus on Microchip Electrophoresis.

Authors:  Giuseppe Caruso; Nicolò Musso; Margherita Grasso; Angelita Costantino; Giuseppe Lazzarino; Fabio Tascedda; Massimo Gulisano; Susan M Lunte; Filippo Caraci
Journal:  Micromachines (Basel)       Date:  2020-06-15       Impact factor: 2.891

4.  An Electrochemical Cholesterol Biosensor Based on A CdTe/CdSe/ZnSe Quantum Dots-Poly (Propylene Imine) Dendrimer Nanocomposite Immobilisation Layer.

Authors:  Kefilwe Vanessa Mokwebo; Oluwatobi Samuel Oluwafemi; Omotayo Ademola Arotiba
Journal:  Sensors (Basel)       Date:  2018-10-09       Impact factor: 3.576

5.  Development and validation of a high-performance thin layer chromatography method for the determination of cholesterol concentration.

Authors:  Jinu John; Ankit Reghuwanshi; Usha K Aravind; C T Aravindakumar
Journal:  J Food Drug Anal       Date:  2014-08-23       Impact factor: 6.157

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.