Literature DB >> 28905952

Detection of membrane-bound and soluble antigens by magnetic levitation.

Mikkel Schou Andersen1, Emily Howard, Shulin Lu, Matthew Richard, Mark Gregory, Gordon Ogembo, Ofer Mazor, Pavel Gorelik, Nathan I Shapiro, Anish V Sharda, Ionita Ghiran.   

Abstract

Magnetic levitation is a technique for measuring the density and the magnetic properties of objects suspended in a paramagnetic field. We describe a novel magnetic levitation-based method that can specifically detect cell membrane-bound and soluble antigens by measurable changes in levitation height that result from the formation of antibody-coated bead and antigen complex. We demonstrate our method's ability to sensitively detect an array of membrane-bound and soluble antigens found in blood, including T-cell antigen CD3, eosinophil antigen Siglec-8, red blood cell antigens CD35 and RhD, red blood cell-bound Epstein-Barr viral particles, and soluble IL-6, and validate the results by flow cytometry and immunofluorescence microscopy performed in parallel. Additionally, employing an inexpensive, single lens, manual focus, wifi-enabled camera, we extend the portability of our method for its potential use as a point-of-care diagnostic assay.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28905952      PMCID: PMC5642277          DOI: 10.1039/c7lc00402h

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  34 in total

Review 1.  Investigating membrane protein dynamics in living cells.

Authors:  Ian R Bates; Paul W Wiseman; John W Hanrahan
Journal:  Biochem Cell Biol       Date:  2006-12       Impact factor: 3.626

2.  Detection and quantification of subtle changes in red blood cell density using a cell phone.

Authors:  Edward J Felton; Anthony Velasquez; Shulin Lu; Ryann O Murphy; Abdala ElKhal; Ofer Mazor; Pavel Gorelik; Anish Sharda; Ionita C Ghiran
Journal:  Lab Chip       Date:  2016-08-16       Impact factor: 6.799

3.  Structural origins of high-affinity biotin binding to streptavidin.

Authors:  P C Weber; D H Ohlendorf; J J Wendoloski; F R Salemme
Journal:  Science       Date:  1989-01-06       Impact factor: 47.728

4.  Primate erythrocyte-immune complex-clearing mechanism.

Authors:  J B Cornacoff; L A Hebert; W L Smead; M E VanAman; D J Birmingham; F J Waxman
Journal:  J Clin Invest       Date:  1983-02       Impact factor: 14.808

5.  Kinetics of two-site immunoradiometric ('sandwich') assays-II. Studies on the nature of the 'high-dose hook effect'.

Authors:  D Rodbard; Y Feldman; M L Jaffe; L E Miles
Journal:  Immunochemistry       Date:  1978-02

6.  Ligation of complement receptor 1 increases erythrocyte membrane deformability.

Authors:  Aleksandra M Glodek; Rossen Mirchev; David E Golan; Joseph A Khoory; Jennie M Burns; Sergey S Shevkoplyas; Anne Nicholson-Weller; Ionita C Ghiran
Journal:  Blood       Date:  2010-09-22       Impact factor: 22.113

7.  A smartphone dongle for diagnosis of infectious diseases at the point of care.

Authors:  Tassaneewan Laksanasopin; Tiffany W Guo; Samiksha Nayak; Archana A Sridhara; Shi Xie; Owolabi O Olowookere; Paolo Cadinu; Fanxing Meng; Natalie H Chee; Jiyoon Kim; Curtis D Chin; Elisaphane Munyazesa; Placidie Mugwaneza; Alex J Rai; Veronicah Mugisha; Arnold R Castro; David Steinmiller; Vincent Linder; Jessica E Justman; Sabin Nsanzimana; Samuel K Sia
Journal:  Sci Transl Med       Date:  2015-02-04       Impact factor: 17.956

8.  Antibody CR1-2B11 recognizes a non-polymorphic epitope of human CR1 (CD35).

Authors:  C-H Chen; I Ghiran; F J M Beurskens; G Weaver; J A Vincent; A Nicholson-Weller; L B Klickstein
Journal:  Clin Exp Immunol       Date:  2007-06       Impact factor: 4.330

9.  Comparison between CRP and IL-6 as early markers of neonatal sepsis.

Authors:  M K Noor; M Shahidullah; M Mutanabbi; C Barua; M A Mannan; S Afroza
Journal:  Mymensingh Med J       Date:  2008-07

Review 10.  The structural basis of antibody-antigen recognition.

Authors:  Inbal Sela-Culang; Vered Kunik; Yanay Ofran
Journal:  Front Immunol       Date:  2013-10-08       Impact factor: 7.561

View more
  2 in total

1.  A Novel Implementation of Magnetic Levitation to Quantify Leukocyte Size, Morphology, and Magnetic Properties to Identify Patients With Sepsis.

Authors:  Mikkel S Andersen; Shulin Lu; Gregory J Lopez; Annmarie T Lassen; Nathan I Shapiro; Ionita C Ghiran
Journal:  Shock       Date:  2019-02       Impact factor: 3.454

2.  Shape oscillations of single blood drops: applications to human blood and sickle cell disease.

Authors:  Vahideh Ansari Hosseinzadeh; Carlo Brugnara; R Glynn Holt
Journal:  Sci Rep       Date:  2018-11-14       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.