Reduction of metal artifacts from unilateral hip arthroplasty on dual-energy CT with metal artifact reduction software.

Dong Yue1, Cheng Fan Rong1,2, Cai Ning2, Hu Liang2, Liu Ai Lian2, Wang Ru Xin2, Luo Ya Hong1.   

Abstract

Background The evaluation of hip arthroplasty is a challenge in computed tomography (CT). The virtual monochromatic spectral (VMS) images with metal artifact reduction software (MARs) in spectral CT can reduce the artifacts and improve the image quality. Purpose To evaluate the effects of VMS images and MARs for metal artifact reduction in patients with unilateral hip arthroplasty. Material and Methods Thirty-five patients underwent dual-energy CT. Four sets of VMS images without MARs and four sets of VMS images with MARs were obtained. Artifact index (AI), CT number, and SD value were assessed at the periprosthetic region and the pelvic organs. The scores of two observers for different images and the inter-observer agreement were evaluated. Results The AIs in 120 and 140 keV images were significantly lower than those in 80 and 100 keV images. The AIs of the periprosthetic region in VMS images with MARs were significantly lower than those in VMS images without MARs, while the AIs of pelvic organs were not significantly different. VMS images with MARs improved the accuracy of CT numbers for the periprosthetic region. The inter-observer agreements were good for all the images. VMS images with MARs at 120 and 140 keV had higher subjective scores and could improve the image quality, leading to reliable diagnosis of prosthesis-related problems. Conclusion VMS images with MARs at 120 and 140 keV could significantly reduce the artifacts from hip arthroplasty and improve the image quality at the periprosthetic region but had no obvious advantage for pelvic organs.

Entities:  

Keywords:  Computed tomography (CT); dual-energy CT; hip prosthesis; metal artifact; metal artifact reduction software; virtual monochromatic image

Mesh:

Substances:

Year:  2017        PMID: 28899125     DOI: 10.1177/0284185117731475

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  9 in total

1.  Evaluation of peri-prosthetic radiolucent lines surrounding the cementless femoral stem using digital tomosynthesis with metal artifact reduction: a cadaveric study in comparison with radiography and computed tomography.

Authors:  Hao Tang; Xingjian Huang; Xiaoguang Cheng; Dejin Yang; Yong Huang; Yixin Zhou
Journal:  Quant Imaging Med Surg       Date:  2020-09

2.  Metal implants on abdominal CT: does split-filter dual-energy CT provide additional value over iterative metal artifact reduction?

Authors:  Hildegard M Wichtmann; Kai R Laukamp; Sebastian Manneck; Konrad Appelt; Bram Stieltjes; Daniel T Boll; Matthias R Benz; Markus M Obmann
Journal:  Abdom Radiol (NY)       Date:  2022-09-30

3.  Improving Structure Delineation for Radiation Therapy Planning Using Dual-Energy CT.

Authors:  George Noid; Justin Zhu; An Tai; Nilesh Mistry; Diane Schott; Douglas Prah; Eric Paulson; Christopher Schultz; X Allen Li
Journal:  Front Oncol       Date:  2020-08-28       Impact factor: 6.244

4.  A Novel Metallic Artifact Reduction Technique When Using a Computed Tomography-Guided Percutaneous Metallic Antenna to Ablate Malignant Pulmonary Nodules: A Qualitative and Quantitative Assessment.

Authors:  Guorong Wang; Zhiwei Wang; Zhengyu Jin
Journal:  Med Sci Monit       Date:  2020-06-11

5.  Tibia Adamantinoma Resection and Reconstruction with a Custom-Made Total Tibia Endoprosthesis: A Case Report with 8-Year Follow-Up.

Authors:  Gilber Kask; Toni-Karri Pakarinen; Jyrki Parkkinen; Hannu Kuokkanen; Jyrki Nieminen; Minna K Laitinen
Journal:  Case Rep Orthop       Date:  2018-06-06

6.  Development of a denoising convolutional neural network-based algorithm for metal artifact reduction in digital tomosynthesis for arthroplasty: A phantom study.

Authors:  Tsutomu Gomi; Rina Sakai; Hidetake Hara; Yusuke Watanabe; Shinya Mizukami
Journal:  PLoS One       Date:  2019-09-13       Impact factor: 3.240

Review 7.  The development of musculoskeletal radiology for 100 years as presented in the pages of Acta Radiologica.

Authors:  Mats Geijer; Fatih Inci; Nektarios Solidakis; Pawel Szaro; Bariq Al-Amiry
Journal:  Acta Radiol       Date:  2021-10-19       Impact factor: 1.990

8.  Application of metal artifact reduction software in gemstone spectral computed tomography for patients after total knee arthroplasty.

Authors:  Jinge Zhang; Xiaozhou Wang; Fei Zhao; Kai Zhang; Yuming Li; Yu Zhang; Yi Zeng; Chunchao Xia; Zhenlin Li
Journal:  Ann Transl Med       Date:  2022-08

9.  Metal artifacts reduction in computed tomography: A phantom study to compare the effectiveness of metal artifact reduction algorithm, model-based iterative reconstruction, and virtual monochromatic imaging.

Authors:  Takuya Ishikawa; Shigeru Suzuki; Shingo Harashima; Rika Fukui; Masafumi Kaiume; Yoshiaki Katada
Journal:  Medicine (Baltimore)       Date:  2020-12-11       Impact factor: 1.817

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.