Literature DB >> 28890655

Comparison of 3 Derivatization Methods for the Analysis of Amphetamine-Related Drugs in Oral Fluid by Gas Chromatography-Mass Spectrometry.

Khaled M Mohamed1, Abdulsallam Bakdash1.   

Abstract

The heptafluorobutyric anhydride (HFBA), pentafluoropropionic anhydride (PFPA), and trifluoroacetic anhydride (TFAA) are compared as derivatizing reagents to use as the optimal method for the analysis of 10 amphetamines and cathinones in oral fluid. The target compounds were amphetamine (AMP), methamphetamine (MA), 4-methylamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxy-N-ethylamphetamine (MDEA), cathinone (CAT), methcathinone, mephedrone, and ephedrine. Amphetamine-D5, MA-D5, MDA-D5, MDMA-D5, and MDEA-D5 use as internal standards (IS). The analytes and IS were extracted from 0.5 mL of oral fluid by ethyl acetate in the presence of NaOH (0.1 N) as the base and then the dried extracts were derivatized with HFBA, PFPA, or TFAA at 70°C for 30 minutes. The limits of quantification based on signal-to-noise ratios ≥10 were ranged between 2.5 and 10 ng/mL. The calibration graphs were linear in the range of 5 or 10 to 1000 ng/mL for all analytes. Based on sensitivity, the PFPA is proved to be the best for derivatization of the target compounds prior to gas chromatography-mass spectrometry analysis.

Entities:  

Keywords:  Amphetamine; analysis; drugs; gas chromatography; oral fluids

Year:  2017        PMID: 28890655      PMCID: PMC5574487          DOI: 10.1177/1177390117727533

Source DB:  PubMed          Journal:  Anal Chem Insights        ISSN: 1177-3901


Introduction

Amphetamines and related compounds which include amphetamine (AMP), methamphetamine (MA), 4-methylamphetamine (4-MA), 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxy-N-ethylamphetamine (MDEA), cathinone (CAT), and ephedrine (EPH) are widely acknowledged as the drugs of abuse in the market.[1-3] More recently, a new synthetic cathinones such as methcathinone (MC) and mephedrone (MEP) are emerging in the market as a bath salt.[4] Their stimulant, euphoric, anorectic effects appear to be the main reason for its popularity.[5,6] Amphetamines and cathinones are weak bases with relatively low molecular weights. It can diffuse to tissues and biological fluids which have pH lower than blood. In addition to urine and blood, amphetamines and cathinones were detected in alternative biological matrices such as sweat, oral fluid, and hair.[7,8] The use of oral fluid for drug testing has many advantages over conventional matrices, it is safe to collect and can offer a quick and noninvasive specimen and condense the potential for adulteration.[9,10] Indeed, in many cases, the concentration of drugs in oral fluid represents the physiologically active fraction.[11,12] The basic drugs such as the cocaine, amphetamines, and some opioids have similar or higher concentrations in oral fluid than those in plasma; therefore, the use of oral fluid as alternative specimens to blood or urine for testing drugs of abuse has become a great importance in clinical and forensic toxicology.[9,13] Practically, gas chromatography-mass spectrometry (GC-MS) analysis of amphetamines and cathinones without derivatization do not confer satisfactory chromatographic behavior. Acylation of the amino or alkylamino groups of amphetamines or cathinones is required to improve the chromatographic shape. Fluorinated anhydrides such as heptafluorobutyric anhydride (HFBA), pentafluoropropionic anhydride (PFPA), and trifluoroacetic anhydride (TFAA) are the most popular derivatizing agents for the derivatization of amphetamines and cathinones prior to GC-MS analysis[14-33] but it is not clear which would be the most effective one. In this work, 3 acylation reagents, HFBA, PFPA, and TFAA, are evaluated for derivatization of AMP, MA, 4-MA, MDA, MDMA, MDEA, CAT, MC, MEP, and EPH after extraction from the oral fluid.

Materials and Methods

Chemicals, reagents, and materials

Stock standards of d-AMP.HCl, d,l-CAT.HCl, d,l-4-MA.HCl, d,l-MA.HCl, d,l-MDA.HCl, d,l-MDMA.HCl, d,l-MDEA.HCl, d,l-AMP-D5.HCl, d,l-MA-D5.HCl, d,l-MDA-D5.HCl, d,l-MDMA-D5.HCl, and d,l-MDEA-D5.HCl at concentrations of 1.0 mg/mL free base in methanol were obtained from Lipomed AG (Arlesheim, Switzerland). Mephedrone HCl, S(−)-MC HCl and 1S,2R(+)-EPH HCl stock standards at a concentration of 1.0 mg/mL free base in methanol were purchased from Cerilliant (Round Rock, TX, USA). The reagents HFBA, PFPA, and TFAA were supplied by United Chemical (UCT, Bristol, PA, USA). Methanol (high-performance liquid chromatography grade, 99.9%), ethyl acetate (99.9%), and sodium hydroxide (≥99.0%) were purchased from Fisher Scientific (Hampton, NH, USA). The GC vials (1.5 mL) and inserts (150 µL) were obtained from Agilent (Santa Clara, CA, USA).

GC-MS conditions

An Agilent GC-MS-7890B with an Agilent autosampler was used for specimen analysis. The GC was equipped with Agilent HP-5MS (5%-phenyl-methylpolysiloxane) column capillary column (30 m × 250 µm × 0.25 µm film thickness). Helium was used as the carrier gas at a flow rate of 1 mL/min. The injection volume was 2.0 µL and injections were made in splitless mode. The injector and interface temperature were maintained at 280°C. The column temperature program was initialized at 80°C and held for 2 minutes, increased to 150°C at a ramp rate of 8°C/min, and then to 280°C with a ramp rate of 30°C/min. Solvent delay time was 6 minutes, giving a total run time of 15.0 minutes. Electron impact ionization mode was used for ionization. The ionizing energy was 70 eV. Qualitative analysis was conducted in the full scan mode (m/z range: 50-500), and quantification was in the in selected ion monitoring (SIM) mode. The deuterated analogues of amphetamines were used as internal standard (IS) for the target compounds, whereas AMP-D5 for AMP, CAT, and 4-MA; MA-D5 for MA, EPH, MC, and MEP; MDA-D5 for MDA; and MDMA-D5 for MDMA and MDMA-D5 for MDEA. Data analysis was performed using the Agilent GC-MS software (MassHunter).

Standards solutions

A mixture of working solution of amphetamines and cathinones at a concentration of 100 µg/mL was prepared by diluting (1:10) of the stock standards with methanol in a volumetric flask. Further working solutions of 10.0, 1.0, and 0.1 μg/mL were obtained and used for the preparation of calibrators. A mixture of IS at a concentration of 5.0 µg/mL for AMP-D5, MA-D5, MDA-D5, MDMA-D5, and MDEA-D5 was prepared by pipetting 50 µL of each compound (100 µg/mL) in 10-mL volumetric flask and made up to 10 mL with methanol.

Spiked samples

For the linearity study, calibration curves at the concentrations of 5, 10, 25, 50, 100, 500, and 1000 ng/mL were prepared in triplicate by fortifying pool of blank oral fluid with appropriate volumes of the mix working solutions. For the limit of quantification (LOQ) study, a pool of blank oral fluid was fortified with the target compounds at a concentration of 100 ng/mL and then a series of fortified oral fluid (n = 3) at concentrations of 1, 2.5, 5, and 10 ng/mL were prepared.

Sample preparation

To 0.5 mL of oral fluid specimens in 5-mL polypropylene tubes, 50 µL of IS (5.0 µg/mL), 0.5 mL of 0.1 N of NaOH (pH 14), and 3.0 mL of ethyl acetate were added. The tubes were vortex mixed for 3 minutes and centrifuged (3000 rpm) for 5 minutes. The ethyl acetate layer was transferred to 5-mL glass tubes containing 1% HCl in methanol, gently vortexed, and evaporated to dryness using a stream of nitrogen. To the residue, 50 µL of ethyl acetate and 50 µL of HFBA, PFPA, or TFAA were added and heated for 30 minutes at 70°C. Samples were evaporated to dryness under a stream of nitrogen and reconstituted with 50 µL of ethyl acetate.

Measurements procedures

Calibration graphs were established by plotting the peak area ratio of the analyte to the IS versus analyte concentration. The linearity of the method was investigated by evaluation of the correlation coefficient (r2) for each calibration graph and the accuracy (bias) for each calibrator.[34] The acceptable value for bias was ±15% and ±20% for LOQ. Sensitivity for each method was assessed by determining the limit of detection (LOD) and LOQ for all analytes.[34] The LOD was defined as the lowest concentration for which the analyte ion signal-to-noise (S/N) ratio was ≥3 (determined by peak height). The LOQ was defined as the lowest concentration for which the analyte ion S/N ratio was ≥10. Method specificity was evaluated by analysis of 6 different blanks (no analyte or IS) and negative (IS added) oral fluid specimens.[34] Co-eluting peaks that might interfere with detection of analytes or IS was examined.

Results and Discussion

Confirmation of unknown amphetamines and cathinones using GC-MS depends on retention time and mass spectra. When SIM is used in place of full scan, at least 3 characteristic ions should be selected and ion ratios must be evaluated.[35] In this study, SIM was applied to detect and quantify amphetamines and cathinones using 3 different derivatization methods. The mass spectra of HFB, PFP, and TFA derivatives of the target amphetamines and cathinones are shown in Figures 1 to 3. The ions with a higher m/z ratio were used as a quantifier and qualifier ions. Based on S/N, the most intense ion was used as a quantifier and 2 characteristic ions were used as a qualifier. The quantifier and qualifier ions for derivatized amphetamines and cathinones by HFBA, PFPA, and TFAA are presented in Table 1. The principal fragmentation occurs by dissociation of the α and β-carbon bonds, as presented in the figure. The fragment ions at m/z 344, 294, 244 for HFB-, PFP-, and TFA-EPH, respectively, are characteristic ions to distinguish between EPH and MA, whereas the retention times for both are close to each other after PFP and TFA derivatization.
Figure 1.

Mass spectra for HFB derivatives of the target amphetamines and cathinones. AMP indicates amphetamine; CAT, cathinone; EPH, ephedrine; 4-MA, 4-methylamphetamine; MA, methamphetamine; MC, methcathinone; MDA, 3,4-methylenedioxyamphetamine; MDEA, 3,4-methylenedioxy-N-ethylamphetamine; MDMA, 3,4-methylenedioxymethamphetamine; MEP, mephedrone.

Figure 3.

Mass spectra for TFA derivatives of the target amphetamines and cathinones. AMP indicates amphetamine; CAT, cathinone; EPH, ephedrine; 4-MA, 4-methylamphetamine; MA, methamphetamine; MC, methcathinone; MDA, 3,4-methylenedioxyamphetamine; MDEA, 3,4-methylenedioxy-N-ethylamphetamine; MDMA, 3,4-methylenedioxymethamphetamine; MEP, mephedrone.

Table 1.

Ions monitored for gas chromatography-mass spectrometry analysis for HFA, PFP, and TFA derivatives of the target amphetamines and cathinones.

NameHFBA
PFPA
TFAA
Quantifier ions, m/zQualifier ions, m/zQuantifier ions, m/zQualifier ions, m/zQuantifier ions, m/zQualifier ions, m/z
AMP24091, 11819091, 11814091, 118
4-MA132105, 240132105, 190132105, 140
MA254118, 210204160, 118154110, 118
MDA375135, 162162135, 325275135, 162
MDMA254162, 210204162, 339154110, 162
MDEA268240, 403218190, 353168140, 303
CAT10577, 24010577, 19010577, 140
MC254105, 210204105, 160154105, 110
MEP119210, 254119160, 20411991, 154
EPH254210, 344204160, 294154110, 244
AMP-D5244122, 123194122, 12314492, 123
MA-D5258120, 213208119, 163158113, 120
MDA-D5380136, 167167136, 330280136, 167
MDMA-D5258164, 213208164, 344158164, 113
MDEA-D5273241, 408223191, 358173141, 308

Abbreviations: AMP, amphetamine; CAT, cathinone; EPH, ephedrine; HFBA, heptafluorobutyric anhydride; 4-MA, 4-methylamphetamine; MA, methamphetamine; MC, methcathinone; MDA, 3,4-methylenedioxyamphetamine; MDEA, 3,4-methylenedioxy-N-ethylamphetamine; MDMA, 3,4-methylenedioxymethamphetamine; MEP, mephedrone; PFPA, pentafluoropropionic anhydride; TFAA, trifluoroacetic anhydride.

Mass spectra for HFB derivatives of the target amphetamines and cathinones. AMP indicates amphetamine; CAT, cathinone; EPH, ephedrine; 4-MA, 4-methylamphetamine; MA, methamphetamine; MC, methcathinone; MDA, 3,4-methylenedioxyamphetamine; MDEA, 3,4-methylenedioxy-N-ethylamphetamine; MDMA, 3,4-methylenedioxymethamphetamine; MEP, mephedrone. Mass spectra for PFP derivatives of the target amphetamines and cathinones. AMP indicates amphetamine; CAT, cathinone; EPH, ephedrine; 4-MA, 4-methylamphetamine; MA, methamphetamine; MC, methcathinone; MDA, 3,4-methylenedioxyamphetamine; MDEA, 3,4-methylenedioxy-N-ethylamphetamine; MDMA, 3,4-methylenedioxymethamphetamine; MEP, mephedrone. Mass spectra for TFA derivatives of the target amphetamines and cathinones. AMP indicates amphetamine; CAT, cathinone; EPH, ephedrine; 4-MA, 4-methylamphetamine; MA, methamphetamine; MC, methcathinone; MDA, 3,4-methylenedioxyamphetamine; MDEA, 3,4-methylenedioxy-N-ethylamphetamine; MDMA, 3,4-methylenedioxymethamphetamine; MEP, mephedrone. Ions monitored for gas chromatography-mass spectrometry analysis for HFA, PFP, and TFA derivatives of the target amphetamines and cathinones. Abbreviations: AMP, amphetamine; CAT, cathinone; EPH, ephedrine; HFBA, heptafluorobutyric anhydride; 4-MA, 4-methylamphetamine; MA, methamphetamine; MC, methcathinone; MDA, 3,4-methylenedioxyamphetamine; MDEA, 3,4-methylenedioxy-N-ethylamphetamine; MDMA, 3,4-methylenedioxymethamphetamine; MEP, mephedrone; PFPA, pentafluoropropionic anhydride; TFAA, trifluoroacetic anhydride. The calibration graphs for each analyte showed good linearity over the dynamic range of 5 to 2000 or 10 to 2000 ng/mL within 3 regression curves. Linear correlation coefficients (r2) were calculated from the triplicate analyses at 6 and 7 concentrations. All r2 values were greater than 0.97. The best r2 values were obtained with PFPA (0.99). Linear ranges, accuracy, and precision (n = 3) for each analyte are presented in Tables 2 to 4. Accuracy expressed as a bias and precision expressed as a relative standard deviation were evaluated at each calibration level. The acceptable value for bias was ±15% and ±20% for LOQ. As depicted in the tables, accuracy and precision were within the acceptable limits.
Table 2.

Accuracy and precision data and linearity range (n = 3) for HFA derivatives of the target amphetamines and cathinones.

AnalyteConcentration, ng/mL
51025501005001000
AMP
 Mean ± SD10.5 ± 0.923.6 ± 1.250.2 ± 3.098.7 ± 10.4510.3 ± 45.71017.4 ± 38.3
 %RSD8.95.06.110.69.03.8
 %Bias4.7−5.70.3−1.32.11.7
4-MA
 Mean ± SD5.0 ± 0.310.6 ± 0.724.5 ± 0.952.2 ± 3.696.8 ± 6.5499.3 ± 15.01047.7 ± 51.9
 %RSD5.96.43.56.96.73.05.0
 %Bias0.35.8−1.94.5−3.2−0.14.8
MA
 Mean ± SD4.9 ± 0.59.5 ± 0.924.9 ± 2.051.9 ± 5.699.2 ± 10.9522.1 ± 62.61064.4 ± 67.5
 %RSD10.59.48.010.711.012.06.3
 %Bias−2.5−5.3−0.43.9−0.84.46.4
MDA
 Mean ± SD9.9 ± 1.025.9 ± 1.352.8 ± 4.090.8 ± 2.6491.8 ± 58.71095.3 ± 25.0
 %RSD10.15.07.62.811.92.3
 %Bias−0.63.75.6−9.2−1.69.5
MDMA
 Mean ± SD4.7 ± 0.510.4 ± 0.825.3 ± 0.953.3 ± 2.291.0 ± 3.0517.1 ± 64.61093.8 ± 21.5
 %RSD11.17.83.74.23.312.52.0
 %Bias−5.84.11.26.6−9.13.49.4
MDEA
 Mean ± SD5.1 ± 0.211.0 ± 0.124.6 ± 0.750.7 ± 3.6105.2 ± 7.7465.2 ± 47.81101.1 ± 131.7
 %RSD3.10.62.97.07.310.312.0
 %Bias1.810.4−1.71.45.2−7.010.1
EPH
 Mean ± SD5.1 ± 0.110.1 ± 0.924.9 ± 3.047.9 ± 1.493.9 ± 7.0498.2 ± 29.51166.0 ± 42.4
 %RSD1.89.012.02.97.55.93.6
 %Bias1.10.9−0.5−4.2−6.1−0.416.6
CAT
 Mean ± SD5.3 ± 0.59.0 ± 0.124.8 ± 1.047.4 ± 2.2107.5 ± 4.5545.4 ± 12.01083.2 ± 56.4
 %RSD10.41.73.94.74.22.25.2
 %Bias5.1−10.2−0.7−5.17.59.18.3
MC
 Mean ± SD4.6 ± 0.410.0 ± 0.223.7 ± 1.851.8 ± 2.194.3 ± 8.8488.2 ± 48.31077.0 ± 48.3
 %RSD8.32.27.74.19.49.94.5
 %Bias−7.2−0.4−5.23.5−5.7−2.47.7
MEP
 Mean ± SD5.6 ± 0.611.0 ± 0.125.9 ± 1.447.6 ± 1.9106.4 ± 8.0500.5 ± 16.31041.3 ± 80.9
 %RSD11.00.65.64.07.53.37.8
 %Bias11.010.13.4−4.96.40.14.1

Abbreviations: AMP, amphetamine; CAT, cathinone; EPH, ephedrine; 4-MA, 4-methylamphetamine; MA, methamphetamine; MC, methcathinone; MDA, 3,4-methylenedioxyamphetamine; MDEA, 3,4-methylenedioxy-N-ethylamphetamine; MDMA, 3,4-methylenedioxymethamphetamine; MEP, mephedrone; RSD, relative standard deviation.

Table 4.

Accuracy and precision data and linearity range (n = 3) for TFA derivatives of the target amphetamines and cathinones.

AnalyteConcentration, ng/mL
51025501005001000
AMP
 Mean ± SD5.0 ± 0.211.1 ± 0.123.9 ± 2.345.6 ± 0.490.7 ± 6.6516.8 ± 4.91000.7 ± 1.3
 %RSD3.50.89.60.97.30.90.1
 %Bias−0.510.6−4.2−8.8−9.33.40.1
4-MA
 Mean ± SD5.2 ± 0.110.4 ± 0.625.0 ± 1.550.9 ± 1.695.9 ± 8.4526.9 ± 31.41062.9 ± 4.7
 %RSD1.55.65.93.18.86.00.4
 %Bias3.14.10.21.7−4.15.46.3
MA
 Mean ± SD5.6 ± 0.111.0 ± 0.323.4 ± 1.944.0 ± 0.888.9 ± 0.7443.0 ± 5.61043.7 ± 49.0
 %RSD1.93.18.11.90.81.34.7
MDA
 Mean ± SD4.7 ± 0.29.1 ± 0.124.8 ± 1.745.1 ± 2.693.8 ± 7.4480.6 ± 21.71047.3 ± 25.5
 %RSD4.81.27.05.87.94.52.4
 %Bias−5.8−9.3−0.9−9.9−6.2−3.94.7
MDMA
 Mean ± SD10.4 ± 0.826.5 ± 0.747.9 ± 4.289.0 ± 6.0480.3 ± 19.31075.0 ± 8.9
 %RSD7.52.68.76.74.00.8
 %Bias4.16.0−4.2−11.0−3.97.5
MDEA
 Mean ± SD4.5 ± 0.19.1 ± 0.124.2 ± 1.250.7 ± 3.4106.2 ± 7.4478.3 ± 17.41051.7 ± 142.2
 %RSD3.01.14.96.76.93.613.5
 %Bias−10.2−9.5−3.01.46.2−4.35.2
EPH
 Mean ± SD5.1 ± 0.28.9 ± 0.226.0 ± 1.346.1 ± 2.899.7 ± 13.4523.1 ± 18.41067.5 ± 60.4
 %RSD3.52.55.16.113.53.55.7
 %Bias2.1−10.64.2−7.8−0.34.66.8
CAT
 Mean ± SD4.9 ± 0.210.2 ± 0.623.7 ± 1.854.6 ± 2.7111.3 ± 1.0466.0 ± 39.0981.8 ± 38.4
 %RSD3.75.97.84.90.98.43.9
 %Bias−1.22.3−5.29.211.3−6.8−1.8
MC
 Mean ± SD4.6 ± 0.410.0 ± 0.223.7 ± 1.851.8 ± 2.194.3 ± 8.8488.2 ± 48.31077.0 ± 48.3
 %RSD8.32.27.74.19.49.94.5
 %Bias−7.2−0.4−5.23.5−5.7−2.47.7
MEP
 Mean ± SD5.2 ± 0.111.0 ± 0.125.9 ± 1.447.6 ± 1.9106.4 ± 8.0500.5 ± 16.31041.3 ± 80.9
 %RSD2.30.65.64.07.53.37.8
 %Bias3.310.13.4−4.96.40.14.1

Abbreviations: AMP, amphetamine; CAT, cathinone; EPH, ephedrine; 4-MA, 4-methylamphetamine; MA, methamphetamine; MC, methcathinone; MDA, 3,4-methylenedioxyamphetamine; MDEA, 3,4-methylenedioxy-N-ethylamphetamine; MDMA, 3,4-methylenedioxymethamphetamine; MEP, mephedrone; RSD, relative standard deviation.

Accuracy and precision data and linearity range (n = 3) for HFA derivatives of the target amphetamines and cathinones. Abbreviations: AMP, amphetamine; CAT, cathinone; EPH, ephedrine; 4-MA, 4-methylamphetamine; MA, methamphetamine; MC, methcathinone; MDA, 3,4-methylenedioxyamphetamine; MDEA, 3,4-methylenedioxy-N-ethylamphetamine; MDMA, 3,4-methylenedioxymethamphetamine; MEP, mephedrone; RSD, relative standard deviation. Accuracy and precision data and linearity range (n = 3) for PFP derivatives of the target amphetamines and cathinones. Abbreviations: AMP, amphetamine; CAT, cathinone; EPH, ephedrine; 4-MA, 4-methylamphetamine; MA, methamphetamine; MC, methcathinone; MDA, 3,4-methylenedioxyamphetamine; MDEA, 3,4-methylenedioxy-N-ethylamphetamine; MDMA, 3,4-methylenedioxymethamphetamine; MEP, mephedrone; RSD, relative standard deviation. Accuracy and precision data and linearity range (n = 3) for TFA derivatives of the target amphetamines and cathinones. Abbreviations: AMP, amphetamine; CAT, cathinone; EPH, ephedrine; 4-MA, 4-methylamphetamine; MA, methamphetamine; MC, methcathinone; MDA, 3,4-methylenedioxyamphetamine; MDEA, 3,4-methylenedioxy-N-ethylamphetamine; MDMA, 3,4-methylenedioxymethamphetamine; MEP, mephedrone; RSD, relative standard deviation. A blank sample was analyzed after the highest point of the calibration curve and showed no peaks for the target analytes that the method is free from carryover. The LOQ was measured in SIM mode using blank oral fluid fortified with all analytes at concentrations of 1, 2.5, 5, and 10 ng/mL. The S/N ratio was calculated from triplicate measurements. The lowest concentration at which the S/N ratio was equal or greater than 10 was considered as the LOQ. Table 5 presents the LOQ for all analytes using different derivatization methods. Selected ion monitoring chromatograms for the analysis of blank oral fluid and fortified sample at LOQ for all analytes are shown in Figures 4 to 6. Based on S/N, the best result was given by PFPA. Moreover, use PFPA as derivatizing reagent allows for very low values of the LOQs (2.5 and 5 ng/mL) for some amphetamines and cathinones compared with the method reported by Mohamed et al[29] and Rohrich et al.[33] which has LOQs of 20 and 9.8 to 20.2 ng/mL, respectively.
Table 5.

LOQ for HFA, PFP, and TFA derivatives of the target amphetamines and cathinones.

AnalystLOQ, ng/mL
HFBAPFPATFAA
AMP102.52.5
4-MA2.52.52.5
MA2.52.52.5
MDA102.52.5
MDMA52.510
MDEA2.52.55
CAT2.52.55
MC2.52.55
MEP2.555
EPH2.52.52.5

Abbreviations: AMP, amphetamine; CAT, cathinone; EPH, ephedrine; HFBA, heptafluorobutyric anhydride; LOQ, limit of quantification; 4-MA, 4-methylamphetamine; MA, methamphetamine; MC, methcathinone; MDA, 3,4-methylenedioxyamphetamine; MDEA, 3,4-methylenedioxy-N-ethylamphetamine; MDMA, 3,4-methylenedioxymethamphetamine; MEP, mephedrone; PFPA, pentafluoropropionic anhydride; TFAA, trifluoroacetic anhydride.

Figure 4.

Total ion chromatograms for the gas chromatography-mass spectrometry analysis of HFA derivatives of amphetamines and cathinones at (A) limit of quantification and (B) blank oral fluid. AMP indicates amphetamine; CAT, cathinone; EPH, ephedrine; 4-MA, 4-methylamphetamine; MA, methamphetamine; MC, methcathinone; MDA, 3,4-methylenedioxyamphetamine; MDEA, 3,4-methylenedioxy-N-ethylamphetamine; MDMA, 3,4-methylenedioxymethamphetamine; MEP, mephedrone.

Figure 6.

Total ion chromatograms for the gas chromatography-mass spectrometry analysis of TFA derivatives of amphetamines and cathinones at (A) limit of quantification and (B) blank oral fluid. AMP indicates amphetamine; CAT, cathinone; EPH, ephedrine; 4-MA, 4-methylamphetamine; MA, methamphetamine; MC, methcathinone; MDA, 3,4-methylenedioxyamphetamine; MDEA, 3,4-methylenedioxy-N-ethylamphetamine; MDMA, 3,4-methylenedioxymethamphetamine; MEP, mephedrone.

Total ion chromatograms for the gas chromatography-mass spectrometry analysis of HFA derivatives of amphetamines and cathinones at (A) limit of quantification and (B) blank oral fluid. AMP indicates amphetamine; CAT, cathinone; EPH, ephedrine; 4-MA, 4-methylamphetamine; MA, methamphetamine; MC, methcathinone; MDA, 3,4-methylenedioxyamphetamine; MDEA, 3,4-methylenedioxy-N-ethylamphetamine; MDMA, 3,4-methylenedioxymethamphetamine; MEP, mephedrone. Total ion chromatograms for the gas chromatography-mass spectrometry analysis of PFP derivatives of amphetamines and cathinones at (A) limit of quantification and (B) blank oral fluid. AMP indicates amphetamine; CAT, cathinone; EPH, ephedrine; 4-MA, 4-methylamphetamine; MA, methamphetamine; MC, methcathinone; MDA, 3,4-methylenedioxyamphetamine; MDEA, 3,4-methylenedioxy-N-ethylamphetamine; MDMA, 3,4-methylenedioxymethamphetamine; MEP, mephedrone. Total ion chromatograms for the gas chromatography-mass spectrometry analysis of TFA derivatives of amphetamines and cathinones at (A) limit of quantification and (B) blank oral fluid. AMP indicates amphetamine; CAT, cathinone; EPH, ephedrine; 4-MA, 4-methylamphetamine; MA, methamphetamine; MC, methcathinone; MDA, 3,4-methylenedioxyamphetamine; MDEA, 3,4-methylenedioxy-N-ethylamphetamine; MDMA, 3,4-methylenedioxymethamphetamine; MEP, mephedrone. LOQ for HFA, PFP, and TFA derivatives of the target amphetamines and cathinones. Abbreviations: AMP, amphetamine; CAT, cathinone; EPH, ephedrine; HFBA, heptafluorobutyric anhydride; LOQ, limit of quantification; 4-MA, 4-methylamphetamine; MA, methamphetamine; MC, methcathinone; MDA, 3,4-methylenedioxyamphetamine; MDEA, 3,4-methylenedioxy-N-ethylamphetamine; MDMA, 3,4-methylenedioxymethamphetamine; MEP, mephedrone; PFPA, pentafluoropropionic anhydride; TFAA, trifluoroacetic anhydride. No co-eluting peaks were observed except CAT, and 4-MA could not be separated effectively from EPH if they were derivatized with HFBA or TFAA. However, they have different fragment ions and can be distinguished from each other.

Conclusions

Three acylation reagents, HFBA, PFPA, and TFAA, have been compared with use as derivatizing agents for the analysis of 10 amphetamines and cathinones in oral fluid by GC-MS. The 3 methods have suitable linearity, sensitivity, accuracy, and precision. Based on LOQ, PFPA is proved to be the best for derivatization of AMP, MA, 4-MA, MDA, MDMA, MDEA, CAT, MC, MEP, and EPH after liquid-liquid extraction from the oral fluid samples.
Table 3.

Accuracy and precision data and linearity range (n = 3) for PFP derivatives of the target amphetamines and cathinones.

AnalyteConcentration, ng/mL
51025501005001000
AMP
 Mean ± SD4.7 ± 0.510.4 ± 0.526.6 ± 1.647.1 ± 0.785.9 ± 0.3525.5 ± 78.31000.9 ± 47.9
 %RSD9.95.15.81.60.314.94.8
 %Bias−6.74.36.5−5.8−14.15.10.1
4-MA
 Mean ± SD5.1 ± 0.29.5 ± 0.324.6 ± 0.646.5 ± 0.1105.6 ± 6.4466.9 ± 32.9956.7 ± 76.5
 %RSD3.93.42.40.26.17.08.0
 %Bias1.2−5.2−1.7−7.15.6−6.6−4.3
MA
 Mean ± SD5.4 ± 0.210.6 ± 0.725.0 ± 1.552.7 ± 3.588.7 ± 0.5493.0 ± 42.11033.2 ± 39.3
 %RSD3.26.16.06.60.68.53.8
 %Bias8.46.40.25.3−11.3−1.43.3
MDA
 Mean ± SD5.2 ± 0.19.4 ± 0.726.0 ± 2.754.1 ± 2.889.1 ± 1.4474.5 ± 0.71134.6 ± 13.3
 %RSD1.97.210.35.11.60.11.2
 %Bias4.0−6.44.08.3−10.9−5.113.5
MDMA
 Mean ± SD5.4 ± 0.49.3 ± 0.925.1 ± 1.447.2 ± 3.890.1 ± 1.7461.5 ± 11.31064.8 ± 7.7
 %RSD7.49.25.78.11.82.50.7
 %Bias7.7−7.00.4−5.6−9.9−7.76.5
MDEA
 Mean ± SD4.7 ± 0.110.0 ± 0.326.6 ± 0.752.0 ± 2.5108.1 ± 3.7462.4 ± 12.11070.1 ± 45.7
 %RSD1.93.32.74.83.42.64.3
 %Bias−5.3−0.56.44.08.1−7.57.0
EPH
 Mean ± SD5.3 ± 0.19.0 ± 0.227.4 ± 0.954.1 ± 4.492.5 ± 4.7470.4 ± 46.01060.6 ± 71.1
 %RSD1.62.13.48.25.19.86.7
 %Bias6.8−10.39.58.3−7.5−5.96.1
CAT
 Mean ± SD4.8 ± 0.111.0 ± 0.126.2 ± 1.349.4 ± 1.3106.7 ± 8.0473.4 ± 19.21062.0 ± 35.4
 %RSD2.01.44.92.67.54.13.3
 %Bias−3.49.94.7−1.26.7−5.36.2
MC
 Mean ± SD5.0 ± 0.19.0 ± 0.126.2 ± 0.550.6 ± 5.0103.9 ± 8.2517.2 ± 22.4956.5 ± 43.2
 %RSD2.00.81.89.97.94.34.5
 %Bias−0.8−9.64.91.13.93.4−4.3
MEP
 Mean ± SD5.0 ± 0.28.9 ± 0.124.6 ± 0.750.3 ± 1.6105.2 ± 6.1473.1 ± 34.01101.5 ± 14.8
 %RSD4.31.02.83.15.87.21.3
 %Bias−1.0−10.7−1.50.65.2−5.410.1

Abbreviations: AMP, amphetamine; CAT, cathinone; EPH, ephedrine; 4-MA, 4-methylamphetamine; MA, methamphetamine; MC, methcathinone; MDA, 3,4-methylenedioxyamphetamine; MDEA, 3,4-methylenedioxy-N-ethylamphetamine; MDMA, 3,4-methylenedioxymethamphetamine; MEP, mephedrone; RSD, relative standard deviation.

  31 in total

1.  Measurement uncertainty for the determination of amphetamines in urine by liquid-phase microextraction and gas chromatography-mass spectrometry.

Authors:  Sarah Carobini Werner de Souza Eller Franco de Oliveira; Mauricio Yonamine
Journal:  Forensic Sci Int       Date:  2016-02-02       Impact factor: 2.395

2.  Confirmation of marijuana, cocaine, morphine, codeine, amphetamine, methamphetamine, phencyclidine by GC/MS in urine following immunoassay screening.

Authors:  S J Mulé; G A Casella
Journal:  J Anal Toxicol       Date:  1988 Mar-Apr       Impact factor: 3.367

3.  GC-MS determination of amphetamines in serum using on-line trifluoroacetylation.

Authors:  Elod Hidvégi; Péter Fábián; Zsuzsa Hideg; Gábor Somogyi
Journal:  Forensic Sci Int       Date:  2006-07-12       Impact factor: 2.395

4.  Detection of methamphetamine and amphetamine in a single human hair by gas chromatography/chemical ionization mass spectrometry.

Authors:  O Suzuki; H Hattori; M Asano
Journal:  J Forensic Sci       Date:  1984-04       Impact factor: 1.832

5.  A new GC-MS method for the determination of five amphetamines in human hair.

Authors:  J L Villamor; A M Bermejo; P Fernández; M J Tabernero
Journal:  J Anal Toxicol       Date:  2005-03       Impact factor: 3.367

6.  Detection of Delta9-tetrahydrocannabinol and amphetamine-type stimulants in oral fluid using the Rapid Stat point-of-collection drug-testing device.

Authors:  J Röhrich; S Zörntlein; J Becker; R Urban
Journal:  J Anal Toxicol       Date:  2010-04       Impact factor: 3.367

7.  Rapid simultaneous determination of amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, 3,4-methylenedioxymethamphetamine, and 3,4-methylenedioxyethylamphetamine in urine by solid-phase extraction and GC-MS: a method optimized for high-volume laboratories.

Authors:  Peter R Stout; Carl K Horn; Kevin L Klette
Journal:  J Anal Toxicol       Date:  2002 Jul-Aug       Impact factor: 3.367

Review 8.  Clinical pharmacokinetics of amfetamine and related substances: monitoring in conventional and non-conventional matrices.

Authors:  Rafael de la Torre; Magí Farré; Mónica Navarro; Roberta Pacifici; Piergiorgio Zuccaro; Simona Pichini
Journal:  Clin Pharmacokinet       Date:  2004       Impact factor: 6.447

9.  Determination of Synthetic Cathinones in Urine Using Gas Chromatography-Mass Spectrometry Techniques.

Authors:  Wei-Yin Hong; Ya-Chun Ko; Mei-Chih Lin; Po-Yu Wang; Yu-Pen Chen; Lih-Ching Chiueh; Daniel Yang-Chih Shih; Hsiu-Kuan Chou; Hwei-Fang Cheng
Journal:  J Anal Toxicol       Date:  2015-09-25       Impact factor: 3.367

Review 10.  Mephedrone related fatalities: a review.

Authors:  F P Busardò; C Kyriakou; S Napoletano; E Marinelli; S Zaami
Journal:  Eur Rev Med Pharmacol Sci       Date:  2015-10       Impact factor: 3.507

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.