Literature DB >> 28888071

The effect of ventricular assist device-associated biomaterials on human blood leukocytes.

Gemma Radley1,2, Ina Laura Pieper1,2, Catherine A Thornton1.   

Abstract

Ventricular assist devices (VADs) are an effective bridging or destination therapy for patients with advanced stage heart failure. These devices remain susceptible to adverse events including infection, bleeding, and thrombus; events linked to the foreign body response. Therefore, the biocompatibility of all biomaterials used is crucial to the success of medical devices. Biomaterials common in VADs-DLC: diamond-like carbon coated stainless steel; Sap: single-crystal sapphire; SiN: silicon nitride; Ti: titanium alloy; and ZTA: zirconia-toughened alumina-were tested for their biocompatibility through incubation with whole human blood for 2 h with mild agitation. Blood was then removed and used for: complete cell counts; leukocyte activation and death, and the production of key inflammatory cytokines. All were compared to time 0 and an un-exposed 2 h sample. Monocyte numbers were lower after exposure to DLC, SiN, and ZTA and monocytes showed evidence of activation with DLC, Sap, and SiN. Neutrophils and lymphocytes were unaffected. This approach allows comprehensive analysis of the potential blood damaging effects of biomaterials. Monocyte activation by DLC, Sap, ZTA, and SiN warrants further investigation linking effects on this cell type to unfavorable inflammatory/thrombogenic responses to VADs and other blood handling devices.
© 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1730-1738, 2018. © 2017 Wiley Periodicals, Inc.

Entities:  

Keywords:  biomaterials; blood; flow cytometry; human; ventricular assist devices

Mesh:

Substances:

Year:  2017        PMID: 28888071     DOI: 10.1002/jbm.b.33981

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  4 in total

1.  Neutrophil dysfunction due to continuous mechanical shear exposure in mechanically assisted circulation in vitro.

Authors:  Wenji Sun; Jiafeng Zhang; Aakash Shah; Katherin Arias; Zachary Berk; Bartley P Griffith; Zhongjun J Wu
Journal:  Artif Organs       Date:  2021-09-20       Impact factor: 3.094

Review 2.  The Inflammatory Response to Ventricular Assist Devices.

Authors:  Gemma Radley; Ina Laura Pieper; Sabrina Ali; Farah Bhatti; Catherine A Thornton
Journal:  Front Immunol       Date:  2018-11-15       Impact factor: 7.561

3.  Jellyfish Collagen: A Biocompatible Collagen Source for 3D Scaffold Fabrication and Enhanced Chondrogenicity.

Authors:  Zara Ahmed; Lydia C Powell; Navid Matin; Andrew Mearns-Spragg; Catherine A Thornton; Ilyas M Khan; Lewis W Francis
Journal:  Mar Drugs       Date:  2021-07-22       Impact factor: 5.118

Review 4.  A systematic review on neutrophils interactions with titanium and zirconia surfaces: Evidence from in vitro studies.

Authors:  Gayathiri Elangovan; Joao M Mello-Neto; Santosh K Tadakamadla; Peter Reher; Carlos Marcelo S Figueredo
Journal:  Clin Exp Dent Res       Date:  2022-05-10
  4 in total